FTA for Fire and Poisoning in Shale Oil Refineries

被引:0
作者
Liu Jian [1 ]
Li Donghua [1 ]
Zheng Shuangzhong
Jin Longzhe [1 ]
机构
[1] Univ Sci & Technol Beijing, Sch Civil & Environm Engn, Beijing 100083, Peoples R China
来源
PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B | 2008年 / 7卷
关键词
dry distillation furnace; fault tree analysis; fire; poisoning; cool water pool;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fire and poisoning are common accidents in shale oil refineries. The paper establishes the figures of fault tree for dry distillation furnace fire, cool water pool fire and the top of dry distillation furnace respectively by employing fault tree analysis (FTA) method, Qualitative analysis is performed to discuss causes of the shale oil refinery fire and poisoning. Some improvement measures am promoted.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 5 条
  • [1] FENGZHAORUI, 2004, SAFETY SYSTEM ENG, V132, P89
  • [2] *FUSH PETR IND ED, 1989, HIST FUSH PETR IND E, P6
  • [3] HOUXIANGLIN, 1984, SHALE OIL IND CHINA
  • [4] LIUDONGHUA, 2006, IND SAFETY ENV PROTE, V5, P52
  • [5] Zhi-xun LIU, 2007, COAL PROCESSING COMP, V1, P45