Midodrine for Orthostatic Hypotension: A Systematic Review and Meta-Analysis of Clinical Trials

被引:52
作者
Parsaik, Ajay K. [1 ]
Singh, Balwinder [1 ]
Altayar, Osama [2 ,5 ]
Mascarenhas, Soniya S. [3 ]
Singh, Shannon K. [4 ]
Erwin, Patricia J. [2 ]
Murad, M. Hassan [2 ,5 ]
机构
[1] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[2] Mayo Clin, Rochester, MN 55905 USA
[3] London Training Coll, London, England
[4] Mayo Clin, Dept Gen Surg, Rochester, MN 55905 USA
[5] Mayo Clin, Div Prevent Med, Rochester, MN 55905 USA
关键词
orthostatic hypotension; midodrine; systematic review; meta-analysis; efficacy; safety; DOUBLE-BLIND; BLOOD-PRESSURE; EFFICACY; MANAGEMENT; WITHDRAWAL; QUALITY; PLACEBO; FDA;
D O I
10.1007/s11606-013-2520-3
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
To perform a systematic review and meta-analysis of clinical trials evaluating the efficacy and safety of midodrine in orthostatic hypotension (OH). We searched major databases and related conference proceedings through June 30, 2012. Two reviewers independently selected studies and extracted data. Random-effects meta-analysis was used to pool the outcome measures across studies. Seven trials were included in the efficacy analysis (enrolling 325 patients, mean age 53 years) and two additional trials were included in the safety analysis. Compared to placebo, the mean change in systolic blood pressure was 4.9 mmHg (p = 0.65) and the mean change in mean arterial pressure from supine to standing was -1.7 mmHg (p = 0.45). The change in standing systolic blood pressure before and after giving midodrine was 21.5 mmHg (p < 0.001). A significant improvement was seen in patients' and investigators' global assessment symptoms scale (a mean difference of 0.70 [95 % CI 0.30-1.09; p < 0.001] and 0.80 [95 % CI 0.76-0.85; p < 0.001], respectively). There was a significant increase in risk of piloerection, scalp pruritis, urinary hesitancy/retention, supine hypertension and scalp paresthesia after giving midodrine. The quality of evidence was limited by imprecision, heterogeneity and increased risk of bias. There is insufficient and low quality evidence to support the use of midodrine for OH.
引用
收藏
页码:1496 / 1503
页数:8
相关论文
共 25 条
[1]  
[Anonymous], COCHRANE HDB SYSTEMA
[2]  
Atkins D, 2004, BMJ-BRIT MED J, V328, P1490
[3]   PRELIMINARY-OBSERVATIONS ON THE USE OF MIDODRINE IN TREATING ORTHOSTATIC HYPOTENSION IN FAMILIAL DYSAUTONOMIA [J].
AXELROD, FB ;
KREY, L ;
GLICKSTEIN, JS ;
ALLISON, JW ;
FRIEDMAN, D .
JOURNAL OF THE AUTONOMIC NERVOUS SYSTEM, 1995, 55 (1-2) :29-35
[4]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[5]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188
[6]   Accelerated Approval and Possible Withdrawal of Midodrine [J].
Dhruva, Sanket S. ;
Redberg, Rita F. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 304 (19) :2172-2173
[7]   ALPHA-SYMPATHOMIMETIC TREATMENT OF AUTONOMIC INSUFFICIENCY WITH ORTHOSTATIC HYPOTENSION [J].
FOUADTARAZI, FM ;
OKABE, M ;
GOREN, H .
AMERICAN JOURNAL OF MEDICINE, 1995, 99 (06) :604-610
[8]   Consensus statement on the definition of orthostatic hypotension, neurally mediated syncope and the postural tachycardia syndrome [J].
Freeman, Roy ;
Wieling, Wouter ;
Axelrod, Felicia B. ;
Benditt, David G. ;
Benarroch, Eduardo ;
Biaggioni, Italo ;
Cheshire, William P. ;
Chelimsky, Thomas ;
Cortelli, Pietro ;
Gibbons, Christopher H. ;
Goldstein, David S. ;
Hainsworth, Roger ;
Hilz, Max J. ;
Jacob, Giris ;
Kaufmann, Horacio ;
Jordan, Jens ;
Lipsitz, Lewis A. ;
Levine, Benjamin D. ;
Low, Phillip A. ;
Mathias, Christopher ;
Raj, Satish R. ;
Robertson, David ;
Sandroni, Paola ;
Schatz, Irwin J. ;
Schondorf, Ron ;
Stewart, Julian M. ;
van Dijk, J. Gert .
AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2011, 161 (1-2) :46-48
[9]   GRADE:: what is "quality of evidence" and why is it important to clinicians? [J].
Guyatt, Gordon H. ;
Oxman, Andrew D. ;
Vist, Gunn E. ;
Kunz, Regina ;
Falck-Ytter, Yngve ;
Schunemann, Holger .
BMJ-BRITISH MEDICAL JOURNAL, 2008, 336 (7651) :995-999B
[10]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560