Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology

被引:99
|
作者
Tsai, Tsung-Han [1 ,2 ]
Potsaid, Benjamin [1 ,2 ,3 ]
Tao, Yuankai K. [1 ,2 ]
Jayaraman, Vijaysekhar [4 ]
Jiang, James [3 ]
Heim, Peter J. S. [5 ]
Kraus, Martin F. [1 ,2 ,6 ,7 ]
Zhou, Chao [1 ,2 ]
Hornegger, Joachim [6 ,7 ]
Mashimo, Hiroshi [8 ,9 ]
Cable, Alex E. [3 ]
Fujimoto, James G. [1 ,2 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Thorlabs Inc, Adv Imaging Grp, Newton, NJ USA
[4] Praevium Res Inc, Santa Barbara, CA USA
[5] Thorlabs Quantum Elect Inc, Jessup, MD USA
[6] Univ Erlangen Nurnberg, Pattern Recognit Lab, Nurnberg, Germany
[7] Univ Erlangen Nurnberg, Grad Sch Adv Opt Technol, Nurnberg, Germany
[8] Vet Affairs Healthcare Syst Boston, Boston, MA USA
[9] Harvard Univ, Sch Med, Boston, MA USA
来源
BIOMEDICAL OPTICS EXPRESS | 2013年 / 4卷 / 07期
基金
美国国家卫生研究院;
关键词
FREQUENCY-DOMAIN REFLECTOMETRY; IN-VIVO; SWEPT-SOURCE; MODE-LOCKING; OCT; LASER; MICROSCOPY; SCANS;
D O I
10.1364/BOE.4.001119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 mu m axial resolution, 8 mu m lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated. (C) 2013 Optical Society of America
引用
收藏
页码:1119 / 1132
页数:14
相关论文
共 50 条
  • [31] Tear Film Dynamics and Corneal Ultrastructure With Ultrahigh Speed and Resolution Optical Coherence Tomography
    Leitgeb, R. A.
    Schmoll, T.
    Singh, A.
    Kolbitsch, C.
    Le, T.
    Sting, A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [32] VCSEL Laser Technology for Ultrahigh Speed and Extended Depth Range OCT Imaging of the Retina and Anterior Eye
    Potsaid, Benjamin
    Liu, Jonathan
    Choi, WooJhon
    Grulkowski, Ireneusz
    Jayaraman, Vijaysekhar
    Jiang, James
    Heim, Peter
    Duker, Jay
    Cable, Alex
    Fujimoto, James
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [33] Ultrahigh speed en face OCT capsule for endoscopic imaging
    Liang, Kaicheng
    Traverso, Giovanni
    Lee, Hsiang-Chieh
    Ahsen, Osman Oguz
    Wang, Zhao
    Potsaid, Benjamin
    Giacomelli, Michael
    Jayaraman, Vijaysekhar
    Barman, Ross
    Cable, Alex
    Mashimo, Hiroshi
    Langer, Robert
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (04): : 1146 - 1163
  • [34] Piezoelectric scanning mirrors for endoscopic optical coherence tomography
    Gilchrist, Kristin H.
    McNabb, Ryan P.
    Izatt, Joseph A.
    Grego, Sonia
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2009, 19 (09)
  • [35] Imaging of Iris lesions with high-speed optical coherence tomography
    Bakri, Sophie J.
    Singh, Arun D.
    Lowder, Careen Y.
    Chalita, Maria Regina
    Li, Yan
    Izatt, Joseph A.
    Rollins, Andrew M.
    Huang, David
    OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (01) : 27 - 34
  • [36] Imaging of stratified media using high-speed swept source optical coherence tomography
    Reddikumar, Maddipatla
    Poddar, Raju
    CURRENT SCIENCE, 2018, 114 (02): : 374 - 377
  • [37] Imaging engineered tissues using structural and functional optical coherence tomography
    Liang, Xing
    Graf, Benedikt W.
    Boppart, Stephen A.
    JOURNAL OF BIOPHOTONICS, 2009, 2 (11) : 643 - 655
  • [38] Ultrahigh resolution optical coherence tomography imaging of lung structure using Gaussian shaped super continuum sources
    Nishizawa, N.
    Ishida, S.
    Ohta, T.
    Itoh, K.
    Kitatsuji, M.
    Ohshima, H.
    Hasegawa, Y.
    Matsushima, M.
    Kawabe, T.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [39] Imaging Cone Photoreceptors in 4D Using Ultrahigh Resolution Optical Coherence Tomography With Adaptive Optics
    Kocaoglu, O. P.
    Wang, Q.
    Jonnal, R. S.
    Lee, S.
    Gao, W.
    Miller, D. T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [40] Optical coherence tomography today: speed, contrast, and multimodality
    Drexler, Wolfgang
    Liu, Mengyang
    Kumar, Abhishek
    Kamali, Tschackad
    Unterhuber, Angelika
    Leitgeb, Rainer A.
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (07)