Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology

被引:99
|
作者
Tsai, Tsung-Han [1 ,2 ]
Potsaid, Benjamin [1 ,2 ,3 ]
Tao, Yuankai K. [1 ,2 ]
Jayaraman, Vijaysekhar [4 ]
Jiang, James [3 ]
Heim, Peter J. S. [5 ]
Kraus, Martin F. [1 ,2 ,6 ,7 ]
Zhou, Chao [1 ,2 ]
Hornegger, Joachim [6 ,7 ]
Mashimo, Hiroshi [8 ,9 ]
Cable, Alex E. [3 ]
Fujimoto, James G. [1 ,2 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Thorlabs Inc, Adv Imaging Grp, Newton, NJ USA
[4] Praevium Res Inc, Santa Barbara, CA USA
[5] Thorlabs Quantum Elect Inc, Jessup, MD USA
[6] Univ Erlangen Nurnberg, Pattern Recognit Lab, Nurnberg, Germany
[7] Univ Erlangen Nurnberg, Grad Sch Adv Opt Technol, Nurnberg, Germany
[8] Vet Affairs Healthcare Syst Boston, Boston, MA USA
[9] Harvard Univ, Sch Med, Boston, MA USA
来源
BIOMEDICAL OPTICS EXPRESS | 2013年 / 4卷 / 07期
基金
美国国家卫生研究院;
关键词
FREQUENCY-DOMAIN REFLECTOMETRY; IN-VIVO; SWEPT-SOURCE; MODE-LOCKING; OCT; LASER; MICROSCOPY; SCANS;
D O I
10.1364/BOE.4.001119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 mu m axial resolution, 8 mu m lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated. (C) 2013 Optical Society of America
引用
收藏
页码:1119 / 1132
页数:14
相关论文
共 50 条
  • [21] Simultaneous optical coherence tomography and Scheimpflug imaging using the same incident light
    Li, Xiaoran
    Lawman, Samuel
    Williams, Bryan M.
    Ye, Sicong
    Shen, Yaochun
    Zheng, Yalin
    OPTICS EXPRESS, 2020, 28 (26): : 39660 - 39676
  • [22] Optical Coherence Tomography: Future Trends for Imaging in Glaucoma
    Folio, Lindsey S.
    Wollstein, Gadi
    Schuman, Joel S.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (05) : E554 - E562
  • [23] Optical coherence tomography: An emerging technology for biomedical imaging and optical biopsy
    Fujimoto, JG
    Pitris, C
    Boppart, SA
    Brezinski, ME
    NEOPLASIA, 2000, 2 (1-2): : 9 - 25
  • [24] Ultrahigh-speed optical coherence tomography utilizing all-optical 40 MHz swept-source
    Huo, Tiancheng
    Wang, Chengming
    Zhang, Xiao
    Chen, Tianyuan
    Liao, Wenchao
    Zhang, Wenxin
    Ai, Shengnan
    Hsieh, Jui-Cheng
    Xue, Ping
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (03)
  • [25] Super-achromatic optical coherence tomography capsule for ultrahigh-resolution imaging of esophagus
    Li, Kaiyan
    Liang, Wenxuan
    Mavadia-Shukla, Jessica
    Park, Hyeon-Cheol
    Li, Dawei
    Yuan, Wu
    Wan, Suiren
    Li, Xingde
    JOURNAL OF BIOPHOTONICS, 2019, 12 (03)
  • [26] High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe
    Aguirre, Aaron D.
    Sawinski, Juergen
    Huang, Shu-Wei
    Zhou, Chao
    Denk, Winfried
    Fujimoto, James G.
    OPTICS EXPRESS, 2010, 18 (05): : 4222 - 4239
  • [27] Target imaging in scattering media using ghost imaging optical coherence tomography
    Huyan, Decai
    Lagrosas, Nofel
    Shiina, Tatsuo
    APL PHOTONICS, 2022, 7 (08)
  • [28] Ultrahigh speed spectral-domain optical coherence microscopy
    Lee, Hsiang-Chieh
    Liu, Jonathan J.
    Sheykin, Yury
    Aguirre, Aaron D.
    Connolly, James L.
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (08): : 1236 - 1254
  • [29] Depth-multiplexed optical coherence tomography dual-beam manually-actuated distortion-corrected imaging (DMDI) with a micromotor catheter
    Lee, Anthony M. D.
    MacAulay, Calum
    Lane, Pierre
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (11): : 5678 - 5690
  • [30] Three-dimensional Imaging of Ureter With Endoscopic Optical Coherence Tomography
    Wang, Hui
    Kang, Wei
    Zhu, Hui
    MacLennan, Gregory
    Rollins, Andrew M.
    UROLOGY, 2011, 77 (05) : 1254 - 1258