Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology

被引:99
|
作者
Tsai, Tsung-Han [1 ,2 ]
Potsaid, Benjamin [1 ,2 ,3 ]
Tao, Yuankai K. [1 ,2 ]
Jayaraman, Vijaysekhar [4 ]
Jiang, James [3 ]
Heim, Peter J. S. [5 ]
Kraus, Martin F. [1 ,2 ,6 ,7 ]
Zhou, Chao [1 ,2 ]
Hornegger, Joachim [6 ,7 ]
Mashimo, Hiroshi [8 ,9 ]
Cable, Alex E. [3 ]
Fujimoto, James G. [1 ,2 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[3] Thorlabs Inc, Adv Imaging Grp, Newton, NJ USA
[4] Praevium Res Inc, Santa Barbara, CA USA
[5] Thorlabs Quantum Elect Inc, Jessup, MD USA
[6] Univ Erlangen Nurnberg, Pattern Recognit Lab, Nurnberg, Germany
[7] Univ Erlangen Nurnberg, Grad Sch Adv Opt Technol, Nurnberg, Germany
[8] Vet Affairs Healthcare Syst Boston, Boston, MA USA
[9] Harvard Univ, Sch Med, Boston, MA USA
来源
BIOMEDICAL OPTICS EXPRESS | 2013年 / 4卷 / 07期
基金
美国国家卫生研究院;
关键词
FREQUENCY-DOMAIN REFLECTOMETRY; IN-VIVO; SWEPT-SOURCE; MODE-LOCKING; OCT; LASER; MICROSCOPY; SCANS;
D O I
10.1364/BOE.4.001119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 mu m axial resolution, 8 mu m lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated. (C) 2013 Optical Society of America
引用
收藏
页码:1119 / 1132
页数:14
相关论文
共 50 条
  • [1] Ultrahigh Speed Endoscopic Swept Source Optical Coherence Tomography using a VCSEL Light Source and Micromotor Catheter
    Tsai, Tsung-Han
    Ahsen, Osman O.
    Lee, Hsiang-Chieh
    Liang, Kaicheng
    Giacomelli, Michael G.
    Potsaid, Benjamin M.
    Tao, Yuankai K.
    Jayaraman, Vijaysekhar
    Kraus, Martin F.
    Hornegger, Joachim
    Figueiredo, Marisa
    Huang, Qin
    Mashimo, Hiroshi
    Cable, Alex E.
    Fujimoto, James G.
    ENDOSCOPIC MICROSCOPY IX; AND OPTICAL TECHNIQUES IN PULMONARY MEDICINE, 2014, 8927
  • [2] Ultrahigh speed endoscopic optical coherence tomography for gastroenterology
    Tsai, Tsung-Han
    Lee, Hsiang-Chieh
    Ahsen, Osman O.
    Liang, Kaicheng
    Giacomelli, Michael G.
    Potsaid, Benjamin M.
    Tao, Yuankai K.
    Jayaraman, Vijaysekhar
    Figueiredo, Marisa
    Huang, Qin
    Cable, Alex E.
    Fujimoto, James
    Mashimo, Hiroshi
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (12): : 4387 - 4404
  • [3] Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter
    Lee, Hsiang-Chieh
    Ahsen, Osman Oguz
    Liang, Kaicheng
    Wang, Zhao
    Cleveland, Cody
    Booth, Lucas
    Potsaid, Benjamin
    Jayaraman, Vijaysekhar
    Cable, Alex E.
    Mashimo, Hiroshi
    Langer, Robert
    Traverso, Giovanni
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (08): : 2927 - 2942
  • [4] Piezoelectric Transducer Based Miniature Catheter for Ultrahigh Speed Endoscopic Optical Coherence Tomography
    Tsai, Tsung-Han
    Potsaid, Benjamin M.
    Kraus, Martin
    Liu, Jonathan J.
    Zhou, Chao
    Hornegger, Joachim
    Fujimoto, James G.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [5] Piezoelectric-transducer-based miniature catheter for ultrahigh-speed endoscopic optical coherence tomography
    Tsai, Tsung-Han
    Potsaid, Benjamin
    Kraus, Martin F.
    Zhou, Chao
    Tao, Yuankai K.
    Hornegger, Joachim
    Fujimoto, James G.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (08): : 2438 - 2448
  • [6] Advances in Endoscopic Optical Coherence Tomography Catheter Designs
    Adams, David C.
    Wang, Yan
    Hariri, Lida P.
    Suter, Melissa J.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2016, 22 (03) : 210 - 221
  • [7] Optical coherence tomography - near infrared spectroscopy system and catheter for intravascular imaging
    Fard, Ali M.
    Vacas-Jacques, Paulino
    Hamidi, Ehsan
    Wang, Hao
    Carruth, Robert W.
    Gardecki, Joseph A.
    Tearney, Guillermo J.
    OPTICS EXPRESS, 2013, 21 (25): : 30849 - 30858
  • [8] Endoscopic optical coherence tomography angiography using a forward imaging piezo scanner probe
    Wurster, Lara M.
    Shah, Ronak N.
    Placzek, Fabian
    Kretschmer, Simon
    Niederleithner, Michael
    Ginner, Laurin
    Ensher, Jason
    Minneman, Michael P.
    Hoover, Erich E.
    Zappe, Hans
    Drexler, Wolfgang
    Leitgeb, Rainer A.
    Ataman, Caglar
    JOURNAL OF BIOPHOTONICS, 2019, 12 (04)
  • [9] Multimodality endoscopic optical coherence tomography and fluorescence imaging technology for visualization of layered architecture and subsurface microvasculature
    Li, Yan
    Jing, Joseph
    Yu, Junxiao
    Zhang, Buyun
    Huo, Tiancheng
    Yang, Qiang
    Chen, Zhongping
    OPTICS LETTERS, 2018, 43 (09) : 2074 - 2077
  • [10] Imaging of oocyte development using ultrahigh-resolution full-field optical coherence tomography
    Xiao, Jiaying
    Wang, Bo
    Lu, Guangyin
    Zhu, Ziqiang
    Huang, Yujiao