An Integrated System for 3D Hip Joint Reconstruction from 2D X-rays: A Preliminary Validation Study

被引:17
|
作者
Schumann, Steffen [1 ]
Liu, Li [1 ]
Tannast, Moritz [2 ]
Bergmann, Mathias [3 ]
Nolte, Lutz-P. [1 ]
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, ISTB, CH-3014 Bern, Switzerland
[2] Univ Bern, Dept Orthoped, Inselspital, CH-3014 Bern, Switzerland
[3] Univ Bern, Inst Anat, CH-3014 Bern, Switzerland
关键词
X-ray image; Calibration; Statistical shape model; 3D surface model; Proximal femur; Pelvis; CT;
D O I
10.1007/s10439-013-0822-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.
引用
收藏
页码:2077 / 2087
页数:11
相关论文
共 50 条
  • [31] Integrated 2D and 3D mammography
    Sumkin, Jules H.
    LANCET ONCOLOGY, 2013, 14 (08): : E292 - E293
  • [32] Reconstruction of 3D catheter paths from 2D X-ray projections
    Bender, HJ
    Männer, R
    Poliwoda, C
    Roth, S
    Walz, M
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 981 - 989
  • [33] Atlas-Based 3D Intensity Volume Reconstruction from 2D Long Leg Standing X-Rays: Application to Hard and Soft Tissues in Lower Extremity
    Yu, Weimin
    Zheng, Guoyan
    INTELLIGENT ORTHOPAEDICS: ARTIFICIAL INTELLIGENCE AND SMART IMAGE-GUIDED TECHNOLOGY FOR ORTHOPAEDICS, 2018, 1093 : 105 - 112
  • [34] 3D Reconstruction From 2D CineMRI Orthogonal Slices: A Feasibility Study
    Paganelli, C.
    Lee, D.
    Kipritidis, J.
    Greer, P.
    Riboldi, M.
    Keall, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3606 - 3607
  • [35] Co-registered breast imaging with 3D X-rays and 3D ultrasound
    Kapur, A
    Carson, PL
    Thomenius, K
    Eberhard, JW
    Goodsitt, M
    Kücker, JL
    Roubidoux, MA
    Helvie, M
    Astley, O
    Yamrom, B
    Claus, B
    Alyassin, A
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 38 - 42
  • [36] 3D SHAPE RECONSTRUCTION FROM 2D ISAR MEASUREMENTS
    Sun, Jing
    Shang, She
    Xu, Jia-Dong
    2012 INTERNATIONAL CONFERENCE ON WAVELET ACTIVE MEDIA TECHNOLOGY AND INFORMATION PROCESSING (LCWAMTIP), 2012, : 25 - 28
  • [37] 3D Reconstruction of Garment from a Single 2D Image
    Liu, Hongyan
    PROCEEDINGS OF THE FIBER SOCIETY 2009 SPRING CONFERENCE, VOLS I AND II, 2009, : 1165 - 1168
  • [38] 3D Kidney Reconstruction from 2D Ultrasound Images
    Teresa Alvarez-Gutierrez, Mariana
    Rodrigo Mejia-Rodriguez, Aldo
    Alejandro Cruz-Guerrero, Ines
    Roman Arce-Santana, Edgar
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 393 - 400
  • [39] 3D IMAGE RECONSTRUCTION FROM 2D CT SLICES
    Kamencay, Patrik
    Zachariasova, Martina
    Hudec, Robert
    Benco, Miroslav
    Radil, Roman
    2014 3DTV-CONFERENCE: THE TRUE VISION - CAPTURE, TRANSMISSION AND DISPLAY OF 3D VIDEO (3DTV-CON), 2014,
  • [40] A survey of 3D reconstruction algorithms from 2D images
    Hajjdiab, Hassan
    IMECS 2006: INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, 2006, : 562 - 567