Determination of Nanomolar Mercury(II) Concentration by Anodic-Stripping Voltammetry at a Carbon Paste Electrode Modified with Functionalized Nanoporous Silica Gel

被引:22
|
作者
Javanbakht, Mehran [1 ,2 ]
Khoshsafar, Hamid [3 ]
Ganjali, Mohammad R. [4 ]
Badiei, Alireza [5 ]
Norouzi, Parviz [4 ]
Hasheminasab, Abed [5 ]
机构
[1] Amirkabir Univ Technol, Dept Chem, Tehran, Iran
[2] Amirkabir Univ Technol, Nanosci & Technol Res Ctr, Tehran, Iran
[3] Univ Tarbiat Moallem, Dept Chem, Tehran, Iran
[4] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[5] Univ Tehran, Univ Coll Sci, Fac Chem, Tehran, Iran
关键词
Nanoporous silica gel; Carbon paste electrodes; Anodic stripping voltammetry; Mercury; Cold vapor AAS; CRYSTAL-STRUCTURE; SENSOR; CHLORIDE; CADMIUM; COMPLEX; SAMPLES; VAPOR;
D O I
10.2174/157341109787047899
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study involves the determination of mercury ions at nanomolar level with the employment of the dipyridyl functionalized nanoporous silica gel-chemically modified carbon paste electrode (DPSG-CPE) by anodic stripping voltammetry. The experiments were conducted with a certain electrode composition of 25% paraffin oil, 60% high purity graphite powder and 15% DPSG as well as the usage of 0.20 M KNO3 as supporting medium. The reduction potential and time were set at, -200 mV and 450 s, respectively, and the scan rate at 100 mV s(-1) in the scan range of 200 to 500 mV. The analytical performance of the modified electrode was evaluated with respect to the carbon paste composition, the solution pH at the accumulation step, the preconcentration time, the mercury concentration, the possible interferences and other variables. On this modified electrode, the anodic stripping voltammetric mercury determination at nanomolar level concentrations was successfully attempted. The resulting electrode demonstrated linear response across a wide mercury(II) concentration range (20-100 nM) with a detection limit value of 8 nM, on the basis of a signal to noise ratio of 3. The precision for six determinations (n=6) of 40 and 75 nM mercury(II) was 5.0% and 2.8% (relative standard deviation), respectively. After studying the influence of the potential interfering ions, it was found that the proposed procedure was free from most interference. To testify the accuracy of this method, comparative determination of mercury(II) in wastewater samples by the proposed method and cold vapor AAS method were done and a sufficient sensitivity for the practical analysis of the environmental samples was attained.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [31] Trace determination of cadmium in water using anodic stripping voltammetry at a carbon paste electrode modified with coconut shell powder
    Rajawat D.S.
    Kumar N.
    Satsangee S.P.
    Journal of Analytical Science and Technology, 5 (1)
  • [32] Determination of Trace Tl(I) by Differential Pulse Anodic Stripping Voltammetry Using a Novel Modified Carbon Paste Electrode
    Ghanei-Motlagh, Masoud
    Baghayeri, Mehdi
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (06)
  • [33] ELECTROCHEMICAL DETERMINATION OF ULTRALOW LEVELS (LESS-THAN-10(-12)-M) OF MERCURY BY ANODIC-STRIPPING VOLTAMMETRY USING CHEMICALLY-MODIFIED ELECTRODE
    TURYAN, I
    MANDLER, D
    ELECTROANALYSIS, 1994, 6 (10) : 838 - 843
  • [34] Square wave anodic stripping voltammetry of copper(II) at a MWCNT paste electrode modified with a tetracarbonylmolybdenum(0) nanocomposite
    Saidin, Mohamad Idris
    Isa, Illyas Md
    Ahmad, Mustaffa
    Hashim, Norhayati
    Kamari, Azlan
    Ab Ghani, S.
    Si, Suyanta M.
    MICROCHIMICA ACTA, 2016, 183 (04) : 1441 - 1448
  • [35] Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode
    Ashrafi, Amir M.
    Vytras, Karel
    TALANTA, 2011, 85 (05) : 2700 - 2702
  • [36] Anodic stripping voltammetry analysis of mercury(II) on a pyridine-Au/pyridine/glassy carbon electrode
    Xiao, Hongbo
    Wang, Wenlei
    Pi, Shaofeng
    Cheng, Yan
    Xie, Qingji
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 317 (317):
  • [37] Differential Pulse Anodic Stripping Voltammetry Determination of Lead(II) and Cadmium(II) with Multiwalled Carbon Nanotubes-Thiol Functionalized Chitosan Modified Bismuth Film Electrode
    Guo, Yan
    Ma, Yan
    Gao, Guizhi
    Li, Jun
    Xu, Jianqiang
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (01) : 113 - 118
  • [38] Determination of trace xanthine by anodic stripping voltammetry with carbon nanotube modified glassy carbon electrode
    Zhao, G
    Zang, SQ
    Liu, KZ
    Lin, S
    Liang, J
    Guo, XY
    Zhang, ZJ
    ANALYTICAL LETTERS, 2002, 35 (14) : 2233 - 2244
  • [39] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [40] Using Electrode Made of Carbon Nanotubes and Bismuth Oxide for the Determination of Metal Concentration by Anodic Stripping Voltammetry
    Thi Thu Phuong Nguyen
    Xuan Gian Trinh
    Dao Thi To Uyen
    JOURNAL OF CHEMISTRY, 2019, 2019