Determination of Nanomolar Mercury(II) Concentration by Anodic-Stripping Voltammetry at a Carbon Paste Electrode Modified with Functionalized Nanoporous Silica Gel

被引:22
|
作者
Javanbakht, Mehran [1 ,2 ]
Khoshsafar, Hamid [3 ]
Ganjali, Mohammad R. [4 ]
Badiei, Alireza [5 ]
Norouzi, Parviz [4 ]
Hasheminasab, Abed [5 ]
机构
[1] Amirkabir Univ Technol, Dept Chem, Tehran, Iran
[2] Amirkabir Univ Technol, Nanosci & Technol Res Ctr, Tehran, Iran
[3] Univ Tarbiat Moallem, Dept Chem, Tehran, Iran
[4] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[5] Univ Tehran, Univ Coll Sci, Fac Chem, Tehran, Iran
关键词
Nanoporous silica gel; Carbon paste electrodes; Anodic stripping voltammetry; Mercury; Cold vapor AAS; CRYSTAL-STRUCTURE; SENSOR; CHLORIDE; CADMIUM; COMPLEX; SAMPLES; VAPOR;
D O I
10.2174/157341109787047899
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study involves the determination of mercury ions at nanomolar level with the employment of the dipyridyl functionalized nanoporous silica gel-chemically modified carbon paste electrode (DPSG-CPE) by anodic stripping voltammetry. The experiments were conducted with a certain electrode composition of 25% paraffin oil, 60% high purity graphite powder and 15% DPSG as well as the usage of 0.20 M KNO3 as supporting medium. The reduction potential and time were set at, -200 mV and 450 s, respectively, and the scan rate at 100 mV s(-1) in the scan range of 200 to 500 mV. The analytical performance of the modified electrode was evaluated with respect to the carbon paste composition, the solution pH at the accumulation step, the preconcentration time, the mercury concentration, the possible interferences and other variables. On this modified electrode, the anodic stripping voltammetric mercury determination at nanomolar level concentrations was successfully attempted. The resulting electrode demonstrated linear response across a wide mercury(II) concentration range (20-100 nM) with a detection limit value of 8 nM, on the basis of a signal to noise ratio of 3. The precision for six determinations (n=6) of 40 and 75 nM mercury(II) was 5.0% and 2.8% (relative standard deviation), respectively. After studying the influence of the potential interfering ions, it was found that the proposed procedure was free from most interference. To testify the accuracy of this method, comparative determination of mercury(II) in wastewater samples by the proposed method and cold vapor AAS method were done and a sufficient sensitivity for the practical analysis of the environmental samples was attained.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [21] ANODIC-STRIPPING VOLTAMMETRY OF LEAD USING A COPPER-MERCURY FILM ELECTRODE
    GUNASINGHAM, H
    DALANGIN, RR
    ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 309 - 313
  • [22] CARBON PASTE ELECTRODE MODIFIED WITH Bi NANOPARTICLES - CARBON XEROGEL FOR Pb2+ DETERMINATION BY SQUARE WAVE ANODIC STRIPPING VOLTAMMETRY
    Deac, Aglaia Raluca
    Cotet, Liviu Cosmin
    Turdean, Graziella Liana
    Muresan, Liana Maria
    REVUE ROUMAINE DE CHIMIE, 2015, 60 (7-8) : 697 - 705
  • [23] DETERMINATION OF TRACE ALUMINUM BY ANODIC ADSORPTIVE STRIPPING VOLTAMMETRY USING A MULTI-WALLED CARBON NANOTUBE MODIFIED CARBON PASTE ELECTRODE
    Deng, Peihong
    Fei, Junjie
    Zhang, Jun
    Feng, Yonglan
    ANALYTICAL LETTERS, 2011, 44 (08) : 1521 - 1535
  • [24] Trace determination of molybdenum by anodic adsorptive stripping voltammetry using a multi-walled carbon nanotubes modified carbon paste electrode
    Deng, Pei-Hong
    Fei, Jun-Jie
    Feng, Yong-Lan
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01): : 214 - 220
  • [25] Anodic stripping voltammetric determination of silver ion at a carbon paste electrode modified with carbon nanotubes
    Tashkhourian, Javad
    Javadi, Sana
    Ana, Fatemeh Nami
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 79 - 84
  • [26] Potentiometric Detection of Mercury(II) Ions Using a Carbon Paste Electrode Modified with Substituted Thiourea-Functionalized Highly Ordered Nanoporous Silica
    Javanbakht, Mehran
    Divsar, Faten
    Badiei, Alireza
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Ziarani, Ghodsi Mohammadi
    Chaloosi, Marzieh
    Jahangir, Ali Abdi
    ANALYTICAL SCIENCES, 2009, 25 (06) : 789 - 794
  • [27] Simultaneous Determination of Hg(II), Cd(II), Pb(II) and Zn(II) by Anodic Stripping Voltammetry using Modified Carbon Paste Ionic Liquid Electrode
    Faridan, Ashkan
    Bahmaei, Manochehr
    Sharif, Amirabdolah Mehrdad
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (06): : 810 - 827
  • [28] Polyviologen modified glassy carbon electrode employed for anodic stripping voltammetric determination of mercury(II)
    Cheng, Kuan-Chiao
    Chen, Po-Yu
    ELECTROANALYSIS, 2008, 20 (02) : 207 - 210
  • [29] Ordered Mesoporous Carbon and Thiolated Polyaniline Modified Electrode for Simultaneous Determination of Cadmium(II) and Lead(II) by Anodic Stripping Voltammetry
    Tang, Lin
    Chen, Jun
    Zeng, Guangming
    Zhu, Yuan
    Zhang, Yi
    Zhou, Yaoyu
    Xie, Xia
    Yang, Guide
    Zhang, Sheng
    ELECTROANALYSIS, 2014, 26 (10) : 2283 - 2291
  • [30] Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode
    Giacomino, Agnese
    Abollino, Omella
    Malandrino, Mery
    Mentasti, Edoardo
    TALANTA, 2008, 75 (01) : 266 - 273