Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation

被引:18
作者
Iijima, Ayaka [1 ]
Shimizu, Kimiya [1 ]
Yamagishi, Mayumi [1 ]
Kobashi, Hidenaga [1 ]
Igarashi, Akihito [1 ]
Kamiya, Kazutaka [1 ]
机构
[1] Kitasato Univ, Sch Med, Dept Ophthalmol, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520374, Japan
关键词
C-Quant; Hole ICL; ICL; intraocular forward scattering; subjective forward scattering; IN-SITU KERATOMILEUSIS; COMPENSATION COMPARISON METHOD; INSTITUTE-REFRACTIVE ERROR; OF-LIFE INSTRUMENT; HIGH MYOPIA; RETINAL STRAYLIGHT; OPTICAL-QUALITY; FOLLOW-UP; CLINICAL-EVALUATION; COLLAMER LENS;
D O I
10.1111/aos.13092
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation. MethodsWe prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.28.8years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant, Oculus) preoperatively and 3months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms. ResultsThe mean log(s) was not significantly changed, from 1.07 +/- 0.20 preoperatively, to 1.06 +/- 0.17 postoperatively (Wilcoxon signed-rank test, p=0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r=0.695, p<0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r=-0.575, p=0.017). ConclusionsAccording to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one.
引用
收藏
页码:E716 / E720
页数:5
相关论文
共 35 条
  • [1] Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up
    Alfonso, Jose F.
    Baamonde, Begona
    Fernandez-Vega, Luis
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) : 873 - 880
  • [2] Straylight values 1 month after laser in situ keratomileusis and photorefractive keratectomy
    Beerthuizen, Jeroen J. G.
    Franssen, Luuk
    Landesz, Monika
    van den Berg, Thomas J. T. P.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) : 779 - 783
  • [3] Performance of the compensation comparison method for retinal straylight measurement:: effect of patient's age on repeatability
    Cervino, A.
    Montes-Mico, R.
    Hosking, S. L.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (06) : 788 - 791
  • [4] Retinal straylight and light distortion phenomena in normal and post-LASIK eyes
    Cervino, Alejandro
    Villa-Collar, Cesar
    Gonzalez-Meijome, Jose Manuel
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (10) : 1561 - 1566
  • [5] Reliability of the compensation comparison method for measuring retinal stray light studied using Monte-Carlo simulations
    Coppens, Joris E.
    Franssen, Luuk
    van den Berg, Thomas J. T. P.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (05)
  • [6] Compensation comparison method for assessment of retinal straylight
    Franssen, L
    Coppens, JE
    van den Berg, TJTP
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (02) : 768 - 776
  • [7] Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye
    Fujisawa, Kunitoshi
    Shimizu, Kimiya
    Uga, Shigekazu
    Suzuki, Masanobu
    Nagano, Koichi
    Murakami, Yuuki
    Goseki, Hiroko
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (01) : 114 - 122
  • [8] Reproducibility of straylight measurement by C-Quant for assessment of retinal straylight using the compensation comparison method
    Guber, Ivo
    Bachmann, Lucas M.
    Guber, Josef
    Bochmann, Frank
    Lange, Alex P.
    Thiel, Michael A.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (09) : 1367 - 1371
  • [9] Optical Quality Analysis System:: Instrument for objective clinical evaluation of ocular optical quality
    Güell, JL
    Pujol, J
    Arjona, M
    Diaz-Douton, F
    Artal, P
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07) : 1598 - 1599
  • [10] Psychometric properties of the National Eye Institute-Refractive Error Quality of Life instrument
    Hays, RD
    Mangione, CM
    Ellwein, L
    Lindblad, AS
    Spritzer, KL
    McDonnell, PJ
    [J]. OPHTHALMOLOGY, 2003, 110 (12) : 2292 - 2301