Review of the measuring precision of the new Meibometer® MB550 through repeated measurements in dogs

被引:20
作者
Benz, Petra [1 ]
Tichy, Alexander [2 ]
Nell, Barbara [1 ]
机构
[1] Vet Univ Vienna, Dept Small Anim & Horses, A-1030 Vienna, Austria
[2] Vet Univ Vienna, Dept Nat Sci, A-1030 Vienna, Austria
关键词
dog; lacrimal system; lipid layer of tear film; Meibometer MB550; meibometry; meibomian gland;
D O I
10.1111/j.1463-5224.2008.00660.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A meibometer is a device to measure the delivery rate of lipids on the eyelid margin. The aim of this study is to determine the measuring precision of the new Meibometer((R)) MB550 (Courage-Khazaka electronic GmbH, 50829, Cologne, Germany), linked to a computer, by means of repeated measurements in dogs by different examiners. Two investigators measured the lipid rate on the eyelid margin in 10 healthy dogs for 10 days. One examiner measured the right eye (OD) and the other measured the left eye (OS) for 5 days. After 5 days, the eyes to be measured were switched between the examiners. The new device was able to record all measurement values as charts and curves in comparison to the previous Meibometer, which displayed only one value. Mean meibomium lipid level +/- SD in the OD and OS of 10 dogs in 10 days was 211 +/- 48 MU and 205 +/- 41 MU (meibometer units), respectively. There was no significant difference between OD and OS, but a broad distribution of the values could be found. Gender did not influence the measurements. A significant difference was determined between the measurements in the first 5 days to those in the following 5 days. There was, therefore, also a significant difference in the measurements of the 2 examiners. Meibometry is a minimally invasive lipid measuring method on the eyelid margin. Repeated measurement results obtained by two examiners, with the new device Meibometer MB550 linked to a computer, showed a wide range of values. The measuring precision of the new Meibometer MB550 is therefore questionable.
引用
收藏
页码:368 / 374
页数:7
相关论文
共 21 条
  • [1] Functional aspects of the tear film lipid layer
    Bron, AJ
    Tiffany, JM
    Gouveia, SM
    Yokoi, N
    Voon, LW
    [J]. EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) : 347 - 360
  • [2] Brown MH, 1996, VET COMP OPHTHALMOL, V6, P274
  • [3] POLARIZED-LIGHT BIOMICROSCOPIC OBSERVATIONS ON THE PRE-CORNEAL TEAR FILM .2. KERATOCONJUNCTIVITIS SICCA IN THE DOG
    CARRINGTON, SD
    BEDFORD, PGC
    GUILLON, JP
    WOODWARD, EG
    [J]. JOURNAL OF SMALL ANIMAL PRACTICE, 1987, 28 (08) : 671 - &
  • [4] CARTWRIGHT NK, 2004, ANN M ASS RES VISION, V45, P122
  • [5] CARVOUNIS PE, 2004, ANN M ASS RES VISION, V45, pU122
  • [6] THE CASUAL LEVEL OF MEIBOMIAN LIPIDS IN HUMANS
    CHEW, CKS
    HYKIN, PG
    JANSWEIJER, C
    DIKSTEIN, S
    TIFFANY, JM
    BRON, AJ
    [J]. CURRENT EYE RESEARCH, 1993, 12 (03) : 255 - 259
  • [7] AN INSTRUMENT FOR QUANTIFYING MEIBOMIAN LIPID ON THE LID MARGIN - THE MEIBOMETER
    CHEW, CKS
    JANSWEIJER, C
    TIFFANY, JM
    DIKSTEIN, S
    BRON, AJ
    [J]. CURRENT EYE RESEARCH, 1993, 12 (03) : 247 - 254
  • [8] Identification, quantification and comparison of major non-polar lipids in normal and dry eye tear lipidomes by electrospray tandem mass spectrometry
    Ham, BM
    Jacob, JT
    Keese, MM
    Cole, RB
    [J]. JOURNAL OF MASS SPECTROMETRY, 2004, 39 (11): : 1321 - 1336
  • [9] HELPER LC, 1970, J AM VET MED ASSOC, V157, P72
  • [10] Biochemical analysis of ocular surface mucin abnormalities in dry eye: The canine model
    Hicks, SJ
    Corfield, AP
    Kaswan, RL
    Hirsh, S
    Stern, M
    Bara, J
    Carrington, SD
    [J]. EXPERIMENTAL EYE RESEARCH, 1998, 67 (06) : 709 - 718