Wavelet-based protection strategy for series arc faults interfered by multicomponent noise signals in grid-connected photovoltaic systems

被引:28
作者
Chen, Silei [1 ]
Li, Xingwen [1 ]
Meng, Yu [1 ]
Xie, Zhimin [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
关键词
Grid-connected PV system; Series arc fault; Noise interferences; Feature improvement; Effectiveness sensitivity analysis; Protection strategy; CLASSIFICATION; DIAGNOSIS;
D O I
10.1016/j.solener.2019.03.008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The arc fault protection strategy should be applied in grid-connected photovoltaic (PV) systems to guarantee the human and equipment safety. In this paper, PV series arc faults are conducted in different grid-connected PV systems through the designed experimental platform firstly. Having analyzed these synthetic arc fault current signals through the existing Db9based features used in the resistive system, the amplitude is found no longer increasing during the arc fault period in some frequency bands. Inverters would inject extra multicomponent noises to influence electrical characterization of arc faults in grid-connected PV systems, causing that Db9-based features show undesirable constant even decreasing amplitude patterns. Next, the Rbio3.1-based features have the better symmetric property to achieve the singularity detection of arc faults. The biorthogonality property of Rbio3.1 could further improve the reconstruction accuracy cooperating with the symmetric property. Besides, its higher vanishing moment is able to display the arc salient disturbances more clearly. Then the Rbio3.1 is able to give more arc fault occurrence time discovery pulses and better arc fault separation degree for different switching frequencies, inverter types, and inverter stages. Ideally, its feature improvement ability may not appear under fault-like conditions. Finally, the random forest (RF) outputs the final state recognition result through combining multiple classifications without adjusting parameters. For the desired Rbio3.1-based features, different feature combinations are able to significantly improve the detection accuracy at the acceptable speed for complicated interference scenes in multiple grid-connected PV systems based on the MATLAB platform.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 34 条
  • [1] A Comprehensive Review of Catastrophic Faults in PV Arrays: Types, Detection, and Mitigation Techniques
    Alam, Mohammed Khorshed
    Khan, Faisal
    Johnson, Jay
    Flicker, Jack
    [J]. IEEE JOURNAL OF PHOTOVOLTAICS, 2015, 5 (03): : 982 - 997
  • [2] [Anonymous], 2011, 1699B UND LAB
  • [3] Iris feature extraction through wavelet mel-frequency cepstrum coefficients
    Barpanda, Soubhagya Sankar
    Majhi, Banshidhar
    Sa, Panjak Kumar
    Sangaiah, Arun Kumar
    Bakshi, Sambit
    [J]. OPTICS AND LASER TECHNOLOGY, 2019, 110 : 13 - 23
  • [4] Calderon EM, 2017, ELECTR CONTACT, P312, DOI 10.1109/HOLM.2017.8088105
  • [5] Classification of acoustic noise signals using wavelet spectrum based support vector machine
    Cha, Kyung Joon
    Yoo, Kook-Hyun
    Lee, Chin Uk
    Mun, Byeong Min
    Bae, Suk Joo
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (06) : 2453 - 2462
  • [6] Chen SJ, 2018, IEEE INT CON MULTI
  • [7] Chen SL, 2016, ELECTR CONTACT, P25, DOI 10.1109/HOLM.2016.7780002
  • [8] Emilio P, 2018, ENERGIES, V11
  • [9] Photovoltaic ground fault detection recommendations for array safety and operation
    Flicker, Jack
    Johnson, Jay
    [J]. SOLAR ENERGY, 2016, 140 : 34 - 50