Anterior cruciate ligament reconstruction using autografts and double biodegradable femoral cross-pin fixation: functional, radiographic and MRI outcome after 2-year minimum follow-up

被引:12
作者
Weninger, Patrick [1 ]
Zifko, Benno [1 ]
Liska, Michael [1 ]
Spitaler, Ralf [1 ]
Pelinka, Hartmut [1 ]
Hertz, Harald [1 ]
机构
[1] Trauma Hosp Lorenz Boehler, Ludwig Boltzmann Inst Expt & Clin Traumatol, A-1200 Vienna, Austria
关键词
Anterior cruciate ligament; Reconstruction; Autograft; Biodegradable fixation; Outcome;
D O I
10.1007/s00167-008-0585-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Double biodegradable cross-pins are increasingly used for femoral fixation in arthroscopically assisted reconstruction of the anterior cruciate ligament (ACL). There are no studies combining functional outcome analysis, radiographs and magnetic resonance images (MRI) to evaluate this technique. The authors examined 45 patients after ACL reconstruction using double biodegradable femoral cross-pin fixation and biodegradable tibial interference screw fixation with a minimum follow-up of 24 months. Clinical evaluation included International Knee Documentation Committee (IKDC) and modified Lysholm score. Radiographic analysis included standard X-rays in anterior-posterior and lateral views and Telos stress device measurements. MRI was analyzed to obtain information about hardware, intra-articular graft, osseous graft-integration and cartilage. IKDC score revealed 28 (62.2%) patients with normal knee function (group A), 15 (33.3%) patients with nearly normal (group B) knee function and 2 (4.4%) patients with abnormal knee function (group C). The Lysholm score was 94.6 (+/- 7.2) in the operated knee and 98.8 (+/- 7.4) in the non-operated knee. Mean Telos stress device values were +4.6 (+/- 2.6) in the operated and +3.9 (+/- 2.4) in the non-operated knee. MRI showed an intact intra-articular graft in all but one patient. Complete femoral graft integration was seen in 88.9% and complete tibial graft integration in 86.7%. Biodegradable cross-pins were partially or fully visible in all patients. The biodegradable tibial interference screw was fully visible in 16 (35.6%) and partially visible in 20 (44.4%) patients. Thirty-one (68.9%) patients showed signs of cartilage degeneration on MRI at follow-up. The graft fixation with double biodegradable pin fixation appears to be a reliable technique for ACL reconstruction providing a stable close-to-joint graft fixation.
引用
收藏
页码:988 / 995
页数:8
相关论文
共 40 条
[21]   Donor-site morbidity and anterior knee problems after anterior cruciate ligament reconstruction using autografts [J].
Kartus, J ;
Movin, T ;
Karlsson, J .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2001, 17 (09) :971-980
[22]   The incidence and significance of femoral tunnel widening after quadrupled hamstring anterior cruciate ligament reconstruction using femoral cross pin fixation [J].
Klein, JP ;
Lintner, DM ;
Downs, D ;
Vavrenka, K .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (05) :470-476
[23]   Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adjacent bone [J].
Lajtai, G ;
Humer, K ;
Aitzetmüller, G ;
Unger, F ;
Noszian, I ;
Orthner, E .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (05) :481-488
[24]   Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction:: 5-year follow-up [J].
Lajtai, G ;
Schmiedhuber, G ;
Unger, F ;
Aitzetmüller, G ;
Klein, M ;
Noszian, I ;
Orthner, E .
ARTHROSCOPY, 2001, 17 (06) :597-602
[25]   Outcome of anterior cruciate ligament reconstruction using quadriceps tendon autograft [J].
Lee, S ;
Seong, SC ;
Jo, H ;
Park, YK ;
Lee, MC .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (08) :795-802
[26]   Knee stability and graft function following anterior cruciate ligament reconstruction: Comparison between 11 o'clock and 10 o'clock femoral tunnel placement [J].
Loh, JC ;
Fukuda, Y ;
Tsuda, E ;
Steadman, RJ ;
Fu, FH ;
Woo, SLY .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (03) :297-304
[27]   Hamstring anterior cruciate ligament reconstruction: A comparison of bioabsorbable interference screw and EndoButton-post fixation [J].
Ma, CB ;
Francis, K ;
Towers, J ;
Irrgang, J ;
Fu, FH ;
Harner, CH .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (02) :122-128
[28]   Reconstruction of the anterior cruciate ligament using bone-patellar tendon-bone graft with double biodegradable femoral pin fixation [J].
Mahirogullari, Mahir ;
Oguz, Yucel ;
Ozkan, Huseyin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (07) :646-653
[29]   Donor site morbidity and return to the preinjury activity level after anterior cruciate ligament reconstruction using ipsilateral and contralateral patellar tendon autograft - A retrospective, nonrandomized study [J].
Mastrokalos, DS ;
Springer, J ;
Siebold, R ;
Paessler, HH .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (01) :85-93
[30]   A comparison of bone-patellar tendon-bone and bone-hamstring tendon-bone autografts for anterior cruciate ligament reconstruction [J].
Matsumoto, A ;
Yoshiya, S ;
Muratsu, H ;
Yagi, M ;
Iwasaki, Y ;
Kurosaka, M ;
Kuroda, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (02) :213-219