Very Low 1/f Noise and Radiation-Hardened CMOS Preamplifier for High-Sensitivity Search Coil Magnetometers

被引:16
作者
Rhouni, Amine [1 ]
Sou, Gerard [1 ]
Leroy, Paul [2 ]
Coillot, Christophe [2 ]
机构
[1] Univ Paris 06, Lab Elect & Electromagnetism, F-75252 Paris, France
[2] Ecole Polytech, LPP Lab Plasma Phys, F-91128 Palaiseau, France
关键词
Application specific integrated circuit (ASIC); low 1/f noise; magnetic sensors amplifier; noise equivalent magnetic induction (NEMI); radiation hardened; search coil magnetometer; space plasmas instruments; THERMAL NOISE; TRANSISTORS; SENSORS;
D O I
10.1109/JSEN.2012.2211347
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 4 nV/root Hz at 10 Hz preamplifier with a 12-mW power consumption in complimentary metal-oxide-semiconductor 0.35 mu m technology has been developed to go one step further in the integration of the preamplifier of a search coil magnetometer. The present application-specific integrated circuit (ASIC) preamplifier, combined with a 10-cm length, 12-mm diameter, and 15 000 turns search coil sensor demonstrates a noise equivalent magnetic induction as low as 2 pT/root(Hz) at 10 Hz and 14 fT/root(Hz) at 4 kHz. The measured current noise is only 46 f A/root Hz. AC magnetometers (from 100 mHz to a few kHz) based on search coil sensors are used for space plasma physics investigations because of their excellent robustness and very high sensitivity. The present ASIC preamplifier offers a way to considerably save weight, volume, and power. This paper will focus on the design of the ASIC, driven by the following criteria: low thermal and 1/f noise, radiation hardness for space purpose, and power consumption.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 22 条
[1]   HIGH-FREQUENCY NOISE MEASUREMENTS ON FETS WITH SMALL DIMENSIONS [J].
ABIDI, AA .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1986, 33 (11) :1801-1805
[2]  
Allen P.E., 1987, CMOS analog circuit design
[3]   The Cluster magnetic field investigation [J].
Balogh, A ;
Dunlop, MW ;
Cowley, SWH ;
Southwood, DJ ;
Thomlinson, JG ;
Glassmeier, KH ;
Musmann, G ;
Luhr, H ;
Buchert, S ;
Acuna, MH ;
Fairfield, DH ;
Slavin, JA ;
Riedler, W ;
Schwingenschuh, K ;
Kivelson, MG .
SPACE SCIENCE REVIEWS, 1997, 79 (1-2) :65-91
[4]  
Burch J., 2009, THEMIS MISSION
[5]   DETERMINATION OF SI-SIO2 INTERFACE TRAP DENSITY BY 1/F NOISE MEASUREMENTS [J].
CELIKBUTLER, Z ;
HSIANG, TY .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1988, 35 (10) :1651-1655
[6]   FLICKER NOISE IN CMOS TRANSISTORS FROM SUBTHRESHOLD TO STRONG INVERSION AT VARIOUS TEMPERATURES [J].
CHANG, JM ;
ABIDI, AA ;
VISWANATHAN, CR .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1994, 41 (11) :1965-1971
[7]   Improvements on the design of search coil magnetometer for space experiments [J].
Coillot, C. ;
Moutoussamy, J. ;
Leroy, P. ;
Chanteur, G. ;
Roux, A. .
SENSOR LETTERS, 2007, 5 (01) :167-170
[8]  
CURTIS SA, 1999, 2000209883 NASA
[9]  
Escoubet CP, 1997, SPACE SCI REV, V79, P1
[10]   1/F NOISE AND RADIATION EFFECTS IN MOS DEVICES [J].
FLEETWOOD, DM ;
MEISENHEIMER, TL ;
SCHOFIELD, JH .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1994, 41 (11) :1953-1964