A study of a biodegradable Mg-3Sc-3Y alloy and the effect of self-passivation on the in vitro degradation

被引:53
作者
Brar, Harpreet S. [1 ]
Ball, Jordan P. [1 ]
Berglund, Ida S. [1 ]
Allen, Josephine B. [1 ]
Manuel, Michele V. [1 ]
机构
[1] Univ Florida, Dept Mat Sci & Engn, Gainesville, FL 32611 USA
关键词
Surface passivation; Magnesium; Oxidation; Yttrium; Scandium; RAY PHOTOELECTRON-SPECTROSCOPY; SELECTIVE OXIDATION; MAGNESIUM ALLOY; VIVO CORROSION; BURST RELEASE; DRUG-DELIVERY; SR ALLOYS; MG; COATINGS; ELECTRODEPOSITION;
D O I
10.1016/j.actbio.2012.08.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnesium and its alloys have been investigated for their potential application as biodegradable implant materials. Although properties of magnesium such as biocompatibility and susceptibility to dissolution are desirable for biodegradable implant applications, its high degradation rate and low strength pose a significant challenge. A potential way to reduce the initial degradation rate is to form a self-passivating protective layer on the surface of the alloy. Oxides with a low enthalpy of formation result in a strong thermodynamic driving force to produce oxide surfaces that are more stable than the native oxide (MgO), and possibly reduce the initial degradation rate in these alloys. In the present study a ternary Mg-3 wt.% Sc-3 wt.% Y alloy was investigated and its oxidation behavior studied. The effect of surface passivation on the in vitro degradation rate was studied and the degradation products identified. The results show that the oxide provided an initial degradation barrier and 24 h oxidation resulted in a negligible degradation rate for up to 23 days. Furthermore, the degradation products of the alloy showed no significant toxicity to osteoblastic cells, and cell proliferation studies confirmed cell attachment and proliferation on the surface of the oxidized alloy. (C) 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:5331 / 5340
页数:10
相关论文
共 58 条
[1]  
[Anonymous], 2011, MAGNESIUM MAGNESIUM
[2]  
[Anonymous], 1996, STAND TEST METH DET
[3]  
Avedesian M.M., 1999, MAGNESIUM MAGNESIUM
[4]   Synthesis and characterization of Mg-Ca-Sr alloys for biodegradable orthopedic implant applications [J].
Berglund, Ida S. ;
Brar, Harpreet S. ;
Dolgova, Natalia ;
Acharya, Abhinav P. ;
Keselowsky, Benjamin G. ;
Sarntinoranont, Malisa ;
Manuel, Michele V. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (06) :1524-1534
[5]   Investigation of the mechanical and degradation properties of Mg-Sr and Mg-Zn-Sr alloys for use as potential biodegradable implant materials [J].
Brar, Harpreet S. ;
Wong, Joey ;
Manuel, Michele V. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 7 :87-95
[6]   Magnesium as a biodegradable and bioabsorbable material for medical implants [J].
Brar, Harpreet S. ;
Platt, Manu O. ;
Sarntinoranont, Malisa ;
Martin, Peter I. ;
Manuel, Michele V. .
JOM, 2009, 61 (09) :31-34
[7]  
Brar HS, 2012, DESIGN DEV SELF PASS
[8]   Bone-implant interface strength and osseointegration: Biodegradable magnesium alloy versus standard titanium control [J].
Castellani, Christoph ;
Lindtner, Richard A. ;
Hausbrandt, Peter ;
Tschegg, Elmar ;
Stanzl-Tschegg, Stefanie E. ;
Zanoni, Gerald ;
Beck, Stefan ;
Weinberg, Annelie-Martina .
ACTA BIOMATERIALIA, 2011, 7 (01) :432-440
[9]   Yttrium-promoted selective oxidation of aluminium in the oxidation at 1100°C of an eutectic Ni-Al-Cr3C2 alloy [J].
Castello, P ;
Stott, FH ;
Gesmundo, F .
CORROSION SCIENCE, 1999, 41 (05) :901-918
[10]   In vivo degradation and bone response of a composite coating on Mg-Zn-Ca alloy prepared by microarc oxidation and electrochemical deposition [J].
Chen, Shuai ;
Guan, Shaokang ;
Li, Wen ;
Wang, Huanxin ;
Chen, Juan ;
Wang, Yisheng ;
Wang, Haitao .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (02) :533-543