Hemodynamic assessment of carotid stenosis by functional magnetic resonance imaging

被引:4
|
作者
Jensen, Ulf [1 ]
Boersch, Kathrin [2 ]
Stingele, Robert [2 ]
Jansen, Olav [1 ]
Alfke, Karsten [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Inst Neuroradiol, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Neurol, Kiel, Germany
关键词
carotid stenosis; hemodynamics; functional magnetic resonance imaging;
D O I
10.1159/000147449
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Functional magnetic resonance imaging (fMRI) is a method usually used to identify cortical representations of cerebral functions. Some studies and case reports suggest that stenoses of the brain-supplying arteries influence the BOLD (blood-oxygenation-level-dependent) signal. The objective of this study was to find out whether the BOLD signal differs in the ipsilateral hemisphere of patients with hemodynamically relevant and those with irrelevant stenosis of the internal carotid artery (ICA) and if a successful treatment might have an influence on the BOLD signal. Methods: We included 10 patients with hemodynamically relevant stenosis in group 1; another 10 patients with hemodynamically irrelevant stenosis of the ICA were included in group 2. Patients underwent recanalization by either stenting or operation of the ICA. fMRI with a hand-tapping task was performed before and after treatment. Data were analyzed with 'Statistical Parametric Mapping' 2 for both hemispheres. An asymmetry index (AI, range 0-2) was calculated for the hand motor areas. Results: All data are given as means +/- SD. The mean preinterventional AI in group 1 was 1.08 +/- 0.87 and 0.30 +/- 0.54 in group 2 (p = 0.029). The mean postinterventional AI was 0.32 +/- 0.29 in group 1 and 0.25 +/- 0.21 in group 2 (p = 0.599). Conclusion: fMRI is not only capable of delivering spatial information, but also of distinguishing a hemodynamically relevant from an irrelevant stenosis of the ICA. Copyright (C) 2008 S. Karger AG, Basel.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 50 条
  • [31] Functional magnetic resonance imaging in psychiatry and psychotherapy
    Derntl, B.
    Habel, U.
    Schneider, F.
    NERVENARZT, 2010, 81 (01): : 16 - +
  • [32] A method for functional magnetic resonance imaging of olfaction
    Sobel, N
    Prabhakaran, V
    Desmond, JE
    Glover, GH
    Sullivan, EV
    Gabrieli, JDE
    JOURNAL OF NEUROSCIENCE METHODS, 1997, 78 (1-2) : 115 - 123
  • [33] Tutte Polynomial in Functional Magnetic Resonance Imaging
    Garcia Castrillon, Marlly Veronica
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXVIII, 2015, 9599
  • [34] Review of functional magnetic resonance imaging in schizophrenia
    Kindermann, SS
    Karimi, A
    Symonds, L
    Brown, GG
    Jeste, DV
    SCHIZOPHRENIA RESEARCH, 1997, 27 (2-3) : 143 - 156
  • [35] Functional magnetic resonance imaging in the visual system
    McFadzean, RM
    Condon, BC
    Barr, DB
    JOURNAL OF NEURO-OPHTHALMOLOGY, 1999, 19 (03) : 186 - 200
  • [36] Lie detection by functional magnetic resonance imaging
    Lee, TMC
    Liu, HL
    Tan, LH
    Chan, CCH
    Mahankali, S
    Feng, CM
    Hou, JW
    Fox, PT
    Gao, JH
    HUMAN BRAIN MAPPING, 2002, 15 (03) : 157 - 164
  • [37] On the characteristics of functional magnetic resonance imaging of the brain
    Ogawa, S
    Menon, RS
    Kim, SG
    Ugurbil, K
    ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 1998, 27 : 447 - +
  • [38] Functional magnetic resonance imaging and multiple sclerosis
    Filippi, Massimo
    Rocca, Maria A.
    FUTURE NEUROLOGY, 2006, 1 (01) : 67 - 76
  • [39] Functional magnetic resonance imaging in clinical neurology
    Humberstone, MR
    Sawle, GV
    EUROPEAN NEUROLOGY, 1996, 36 (03) : 117 - 124
  • [40] Hardware considerations for functional magnetic resonance imaging
    Silva, AC
    Merkle, H
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2003, 16A (01): : 35 - 49