Target-filter combination effects on breast tissue characterization using mammographic X-rays: A Monte Carlo simulation study

被引:1
|
作者
Elshemey, Wael M. [1 ]
Saif, Refat Abo [2 ]
Elfiky, Abdo A. [2 ]
机构
[1] Islamic Univ Madinah, Fac Sci, Phys Dept, Madinah, Saudi Arabia
[2] Cairo Univ, Fac Sci, Biophys Dept, Giza, Egypt
关键词
Monte Carlo simulation; breast tissue; X-ray scattering; tissue characterization; mammography; COHERENT SCATTERING; SPECTRA; CANCER; DIAGNOSIS; QUALITY; SYSTEM; FAT; CT;
D O I
10.3233/XST-221154
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Characterization of normal and malignant breast tissues using X-ray scattering techniques has shown promising results and applications. OBJECTIVE: To examine possibility of characterizing normal and malignant breast tissues using the scattered photon distribution of polyenergetic beams of 30 kV X-rays. METHODS: A Monte Carlo simulation is upgraded so that it is capable of simulating input mammographic X-ray spectra from different target-filter combinations, tracing photon transport, and producing the distribution of scattered photons. The target-filter combinations include Mo-Mo, Mo-Al, Mo-Rh, Rh-Rh, Rh-Al, W-Rh, and W-Al. Analysis of obtained scattered photon distribution is carried out by comparing the ratio of count under the peak in the momentum transfer region from 0 to 1.55 nm(-1), to that in the region from 1.6 to 9.1 nm(-1) (covering the regions of scattering from fat and soft tissue, respectively) for breast samples with different percentages of normal tissue (0-100%). RESULTS: Mo-Mo target-filter combination shows a high linear dependence of the count under peak ratio on the percentage of normal tissue in breast samples (R-2 = 0.9513). Despite slightly less linear than Mo-Mo, target-filter combinations other than Rh-Rh, W-Rh, and W-Al produce high linear responses (R-2 > 0.9) CONCLUSIONS: Mo-Mo target-filter combination would probably be the most relevant in characterizing normal and malignant breast tissues from their scattered photon distribution.
引用
收藏
页码:823 / 834
页数:12
相关论文
共 46 条
  • [21] Monte-Carlo simulation of spatial distribution of x-rays in multi-film targets. II: Spatial distribution of continuous x-rays and temperature elevation in W/Al film targets
    Yoshioka, A
    Yamaguchi, Y
    Tamura, K
    Shimizu, R
    SURFACE AND INTERFACE ANALYSIS, 2005, 37 (03) : 356 - 361
  • [22] Preclinical modeling of low energy X-rays radiological burn: Dosimetry study by monte carlo simulations and EPR spectroscopy
    Guillou, Manon
    L'Homme, Bruno
    Trompier, Francois
    Gruel, Gaetan
    Prezado, Yolanda
    Dos Santos, Morgane
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [23] Monte Carlo simulation of X-ray spectra and evaluation of filter effect using MCNP4C and FLUKA code
    Taleei, R.
    Shahriari, M.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (02) : 266 - 271
  • [24] Secondary Fluorescence Correction for Characteristic and Bremsstrahlung X-Rays Using Monte Carlo X-ray Depth Distributions Applied to Bulk and Multilayer Materials
    Yuan, Yu
    Demers, Hendrix
    Rudinsky, Samantha
    Gauvin, Raynald
    MICROSCOPY AND MICROANALYSIS, 2019, 25 (01) : 92 - 104
  • [25] Evaluation of the effect of silicone breast inserts on X-ray mammography and breast tomosynthesis images: A Monte Carlo simulation study
    Daskalaki, A.
    Bliznakova, K.
    Pallikarakis, N.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 353 - 361
  • [26] Characterization of breast tissues combining x-ray fluorescence and scattering spectroscopy: A Monte Carlo computational study
    Antoniassi, M.
    Maciel, K. F. R.
    Manfre, F. A.
    Fagundes, A. C. F.
    Conceicao, A. L. C.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 69 - 74
  • [27] Volumetric x-ray coherent scatter imaging of cancer in resected breast tissue: a Monte Carlo study using virtual anthropomorphic phantoms
    Lakshmanan, Manu N.
    Harrawood, Brian P.
    Samei, Ehsan
    Kapadia, Anuj J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16) : 6355 - 6370
  • [28] Position distribution calculation of annihilation radiations and bremsstrahlung x rays in water during irradiation of positive muons: a Monte Carlo simulation study
    Hirano, Yoshiyuki
    Yamamoto, Seiichi
    Kawamura, Naritoshi
    Ninomiya, Kazuhiko
    PHYSICA SCRIPTA, 2021, 96 (02)
  • [29] Monte-Carlo simulation and experimental study for internal light irradiated tissue using cylindrical diffusing source
    Peng, Dong-Qing
    Xie, Wen-Ming
    Li, Hui
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2015, 26 (07): : 1429 - 1434
  • [30] Effects of patient-specific treatment planning on eligibility for photodynamic therapy of deep tissue abscess cavities: retrospective Monte Carlo simulation study
    Li, Zihao
    Nguyen, Lam
    Bass, David A.
    Baran, Timothy M.
    JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (08)