Target-filter combination effects on breast tissue characterization using mammographic X-rays: A Monte Carlo simulation study

被引:1
|
作者
Elshemey, Wael M. [1 ]
Saif, Refat Abo [2 ]
Elfiky, Abdo A. [2 ]
机构
[1] Islamic Univ Madinah, Fac Sci, Phys Dept, Madinah, Saudi Arabia
[2] Cairo Univ, Fac Sci, Biophys Dept, Giza, Egypt
关键词
Monte Carlo simulation; breast tissue; X-ray scattering; tissue characterization; mammography; COHERENT SCATTERING; SPECTRA; CANCER; DIAGNOSIS; QUALITY; SYSTEM; FAT; CT;
D O I
10.3233/XST-221154
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Characterization of normal and malignant breast tissues using X-ray scattering techniques has shown promising results and applications. OBJECTIVE: To examine possibility of characterizing normal and malignant breast tissues using the scattered photon distribution of polyenergetic beams of 30 kV X-rays. METHODS: A Monte Carlo simulation is upgraded so that it is capable of simulating input mammographic X-ray spectra from different target-filter combinations, tracing photon transport, and producing the distribution of scattered photons. The target-filter combinations include Mo-Mo, Mo-Al, Mo-Rh, Rh-Rh, Rh-Al, W-Rh, and W-Al. Analysis of obtained scattered photon distribution is carried out by comparing the ratio of count under the peak in the momentum transfer region from 0 to 1.55 nm(-1), to that in the region from 1.6 to 9.1 nm(-1) (covering the regions of scattering from fat and soft tissue, respectively) for breast samples with different percentages of normal tissue (0-100%). RESULTS: Mo-Mo target-filter combination shows a high linear dependence of the count under peak ratio on the percentage of normal tissue in breast samples (R-2 = 0.9513). Despite slightly less linear than Mo-Mo, target-filter combinations other than Rh-Rh, W-Rh, and W-Al produce high linear responses (R-2 > 0.9) CONCLUSIONS: Mo-Mo target-filter combination would probably be the most relevant in characterizing normal and malignant breast tissues from their scattered photon distribution.
引用
收藏
页码:823 / 834
页数:12
相关论文
共 46 条
  • [1] Monte Carlo simulation of generations of continuous and characteristic X-rays by electron impact
    Fujii, K
    Nagatomi, T
    Kimura, Y
    Takai, Y
    Shimizu, R
    Obori, K
    Yurugi, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2000, 39 (5A): : 2863 - 2864
  • [2] Development of Monte Carlo simulation of generation of continuous and characteristic X-rays by electron impact
    Obori, K
    Awata, S
    Yurugi, T
    Araki, K
    Nagatomi, T
    Kimura, Y
    Takai, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2002, 41 (3A): : 1616 - 1617
  • [3] Effective energy assessment during breast cancer intraoperative radiotherapy by low-energy X-rays: A Monte Carlo study
    Shamsabadi, Reza
    Baghani, Hamid Reza
    Mowlavi, Ali Asghar
    Azadegan, Behnam
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2021, 60 (01) : 125 - 134
  • [4] A multiscale Monte Carlo simulation of irradiating a typical-size apple by low-energy X-rays and electron beams
    Rafiepour, Payman
    Sina, Sedigheh
    Mortazavi, Seyed Mohammad Javad
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [5] Influence of distant scatterer on air kerma measurement in the evaluation of diagnostic X-rays using Monte Carlo simulation
    Tominaga, Masahide
    Nagayasu, Yukari
    Sasaki, Motoharu
    Furuta, Takuya
    Hayashi, Hiroaki
    Oita, Masataka
    Nishiyama, Yuichi
    Haga, Akihiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (04) : 381 - 389
  • [6] Influence of distant scatterer on air kerma measurement in the evaluation of diagnostic X-rays using Monte Carlo simulation
    Masahide Tominaga
    Yukari Nagayasu
    Motoharu Sasaki
    Takuya Furuta
    Hiroaki Hayashi
    Masataka Oita
    Yuichi Nishiyama
    Akihiro Haga
    Radiological Physics and Technology, 2021, 14 : 381 - 389
  • [7] Lead-free transparent shields for diagnostic X-rays: Monte Carlo simulation and measurements
    Karimi, Milad
    Ghazikhanlou-sani, Karim
    Mehdizadeh, Ali Reza
    Mostaghimi, Hesameddin
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (03) : 276 - 287
  • [8] Lead-free transparent shields for diagnostic X-rays: Monte Carlo simulation and measurements
    Milad Karimi
    Karim Ghazikhanlou-sani
    Ali Reza Mehdizadeh
    Hesameddin Mostaghimi
    Radiological Physics and Technology, 2020, 13 : 276 - 287
  • [9] Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays
    Hashimoto, Masatoshi
    Tomita, Tetsuya
    Sawada, Koichi
    Fujibuchi, Toshioh
    Nishio, Teiji
    Nakagawa, Keiichi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (04)
  • [10] Characterization of an extrapolation chamber for low-energy X-rays: Experimental and Monte Carlo preliminary results
    Neves, Lucio P.
    Silva, Eric A. B.
    Perini, Ana P.
    Maidana, Nora L.
    Caldas, Linda V. E.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1388 - 1391