In Vitro and In Vivo Safety Evaluation of Biodegradable Self-Assembled Monomethyl Poly(Ethylene Glycol)-Poly(ε-Caprolactone)-Poly(Trimethylene Carbonate) Micelles

被引:14
作者
Yang, Xi [1 ,2 ]
Cao, Dan [1 ,2 ]
Wang, Ning [1 ,2 ]
Sun, Lu [1 ,2 ]
Li, Ling [1 ,2 ]
Nie, Shihong [1 ,2 ]
Wu, Qinjie [1 ,2 ]
Liu, Xinyu [1 ,2 ]
Yi, Cheng [1 ,2 ]
Gong, Changyang [1 ,2 ]
机构
[1] Sichuan Univ, State Key Lab Biotherapy, West China Hosp, West China Med Sch, Chengdu 610041, Peoples R China
[2] Sichuan Univ, Ctr Canc, West China Hosp, West China Med Sch, Chengdu 610041, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
nanotechnology; synthesis; polymers; biodegradable; biocompatibility; self-assembly; micelle; MPEG-P(CL-co-TMC); toxicity evaluation; PH-SENSITIVE HYDROGEL; DRUG-DELIVERY SYSTEMS; WATER-SOLUBLE DRUGS; TRIMETHYLENE CARBONATE; EPSILON-CAPROLACTONE; POLYMERIC MICELLES; BLOCK-COPOLYMERS; NANOPARTICLES; DEGRADATION; THERAPEUTICS;
D O I
10.1002/jps.23800
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Safety evaluation of self-assembled polymeric micelles is important for biomedical involvement in drug delivery systems in the future. In this study, biodegradable monomethyl poly (ethylene glycol)-poly (epsilon-caprolactone)-poly (trimethylene carbonate) [MPEG-P(CL-co-TMC)] copolymer was synthesized and characterized by Fourier transform infrared spectroscopy, nuclear magnetic resonance analysis, and gel permeation chromatography. MPEG-P(CL-co-TMC) micelles were prepared by self-assembly without any organic solvent. The present study was conducted to assess the safety of blank MPEG-P(CL-co-TMC) micelles both in vitro and in vivo. Particle size (30.09 +/- 0.06 nm) and zeta potential (0.067 +/- 0.027 mV) of obtained micelles were determined by Malvern laser particle size analyzer. The results of in vitro toxicity evaluation implied that the prepared micelles did not cause hemolysis or severely cell toxicity. Meanwhile, we did not observe any toxic response or histopathological changes in the study of in vivo acute toxicity evaluation and histopathological study of MPEG-P(CL-co-TMC) micelles. In conclusion, the maximal tolerance dose of MPEG-P(CL-co-TMC) micelles (100 mg/mL) by intravenous injection was supposed to be greater than 10 g/kg body weight. Therefore, it might have potential applications in biomedical field. (c) 2013 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 103:305-313, 2014
引用
收藏
页码:305 / 313
页数:9
相关论文
共 49 条
  • [1] Freeze-drying of nanoparticles: Formulation, process and storage considerations
    Abdelwahed, Wassim
    Degobert, Ghania
    Stainmesse, Serge
    Fessi, Hatem
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2006, 58 (15) : 1688 - 1713
  • [2] Nano-engineering block copolymer aggregates for drug delivery
    Allen, C
    Maysinger, D
    Eisenberg, A
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 1999, 16 (1-4) : 3 - 27
  • [3] Drug delivery systems: Entering the mainstream
    Allen, TM
    Cullis, PR
    [J]. SCIENCE, 2004, 303 (5665) : 1818 - 1822
  • [4] Ligand-targeted therapeutics in anticancer therapy
    Allen, TM
    [J]. NATURE REVIEWS CANCER, 2002, 2 (10) : 750 - 763
  • [5] Trimethylene Carbonate and ε-Caprolactone Based (co)Polymer Networks: Mechanical Properties and Enzymatic Degradation
    Bat, Erhan
    Plantinga, Josee A.
    Harmsen, Martin C.
    van Luyn, Marja J. A.
    Zhang, Zheng
    Grijpma, Dirk W.
    Feijen, Jan
    [J]. BIOMACROMOLECULES, 2008, 9 (11) : 3208 - 3215
  • [6] Characterization of self-assembling copolymers in aqueous solutions using Electron Paramagnetic Resonance and Fluorescence spectroscopy
    Beghein, N.
    Rouxhet, L.
    Dinguizli, M.
    Brewster, M. E.
    Arien, A.
    Preat, V.
    Habib, J. L.
    Gallez, B.
    [J]. JOURNAL OF CONTROLLED RELEASE, 2007, 117 (02) : 196 - 203
  • [7] Self-assembling materials for therapeutic delivery
    Branco, Monica C.
    Schneider, Joel P.
    [J]. ACTA BIOMATERIALIA, 2009, 5 (03) : 817 - 831
  • [8] Aliphatic polyester polymer stars: synthesis, properties and applications in biomedicine and nanotechnology
    Cameron, Donald J. A.
    Shaver, Michael P.
    [J]. CHEMICAL SOCIETY REVIEWS, 2011, 40 (03) : 1761 - 1776
  • [9] Acute oral toxicity evaluation of biodegradable and pH-sensitive hydrogel based on polycaprolactone, poly(ethylene glycol) and methylacrylic acid (MAA)
    Chen, Xian
    Qian, ZhiYong
    Gou, MaLing
    Chao, GuoTao
    Zhang, YangDe
    Gu, YingChun
    Huang, MeiJuan
    Wang, JiWei
    Pan, YiFeng
    Wei, YuQuan
    Chen, JianPing
    Tu, MingJing
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 84A (03) : 589 - 597
  • [10] Polymeric micelles for drug delivery
    Croy, S. R.
    Kwon, G. S.
    [J]. CURRENT PHARMACEUTICAL DESIGN, 2006, 12 (36) : 4669 - 4684