Semiautomatic Sizing Software in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms

被引:6
|
作者
Reimerink, Jorik J. [1 ]
Marquering, Henk A. [2 ,3 ]
Vahl, Anco [4 ]
Wisselink, Willem [5 ]
Schreve, Michiel A. [4 ]
De Boo, Diederick W. [3 ]
Reekers, Jim A. [3 ]
Legemate, Dink A. [1 ]
Balm, Ron [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Vasc Surg, Vasc Surg Sect, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[4] Onze Lieve Vrouw Hosp, Dept Vasc Surg, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, Dept Vasc Surg, Amsterdam, Netherlands
关键词
Aortic aneurysm; Abdominal; Endovascular procedure; Computed tomography; Ruptured AAA; EVAR evaluation; CT-ANGIOGRAPHY; INTEROBSERVER; RELIABILITY; TRIAL;
D O I
10.1007/s00270-013-0757-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In emergency endovascular repair (EVAR) of ruptured aneurysms of the aorta (rAAA), anatomical suitability must be determined. Semiautomatic three-dimensional assessment of the aortoiliac arteries has the potential to standardise measurements. This study assesses the fitness for purpose of such a semiautomatic approach for rAAA and determined interobserver agreement on suitability. Interobserver study with six trained observers (4 vascular surgeons, 2 radiologists) blindly assessing preoperative computed tomography angiography scans of 50 consecutive patients with rAAA. A central lumen line (CLL) was generated, and perpendicular diameters, length along the CLL, and EVAR suitability were determined using dedicated sizing software (3mensio; 3mensio Vascular; Bilthoven, The Netherlands). Success of generating a CLL, time of assessment, and interobserver agreement was determined. In the majority of the patients (median 76 %, range 64-78 %), a CLL was semiautomatically generated. The median duration of CLL generation and performance measurements was 7.5 min (interquartile range 5.5-10.6). Agreement on suitability was moderate for the entire group (Fleiss' kappa = 0.55, confidence interval 0.48-0.62) and ranged from moderate to good (Cohen's kappa = 0.40-0.72) between observer pairs. Assessing EVAR suitability of rAAA patients using dedicated sizing software is possible in the majority of patients. The measurements can be performed in a reasonable amount of time, and the agreement of suitability for EVAR in patients with rAAA is moderate. Improvements and additional research are necessary to replace the current axial measurement.
引用
收藏
页码:623 / 630
页数:8
相关论文
共 50 条
  • [21] Open repair for ruptured abdominal aortic aneurysms
    Antonello, M.
    ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 16 (03): : 163 - 177
  • [22] Endovascular proximal control of ruptured abdominal aortic aneurysms: the internal aortic clamp
    Assar, A. N.
    Zarins, C. K.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2009, 50 (03) : 381 - 385
  • [23] Early and Midterm Outcomes of Chimney Endovascular Aortic Repair for Ruptured Abdominal Aortic Aneurysms
    Takeuchi, Yuriko
    Morikage, Noriyasu
    Sakamoto, Ryunosuke
    Otsuka, Ryo
    Ike, Soichi
    Mizoguchi, Takahiro
    Samura, Makoto
    Harada, Takasuke
    Kurazumi, Hiroshi
    Suzuki, Ryo
    Suehiro, Kotaro
    Hamano, Kimikazu
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [24] Endovascular Aneurysm Repair Is Not the Treatment of Choice in Most Patients with Ruptured Abdominal Aortic Aneurysm
    Livesay, James J.
    Talledo, Oscar G.
    TEXAS HEART INSTITUTE JOURNAL, 2013, 40 (05) : 556 - 559
  • [25] Editor's Choice - The Impact of Centralisation and Endovascular Aneurysm Repair on Treatment of Ruptured Abdominal Aortic Aneurysms Based on International Registries
    Budtz-Lilly, Jacob
    Bjorck, Martin
    Venermo, Maarit
    Debus, Sebastian
    Behrendt, Christian-Alexander
    Altreuther, Martin
    Beiles, Barry
    Szeberin, Zoltan
    Eldrup, Nikolaj
    Danielsson, Gudmundur
    Thomson, Ian
    Wigger, Pius
    Khashram, Manar
    Loftus, Ian
    Mani, Kevin
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2018, 56 (02) : 181 - 188
  • [26] Aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms
    Badran, MF
    Gould, DA
    Raza, I
    McWilliams, RG
    Brown, O
    Harris, PL
    Gilling-Smith, GL
    Brennan, J
    White, D
    Meakin, S
    Rowlands, PC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (09) : 887 - 892
  • [27] Endovascular treatment for ruptured abdominal aortic aneurysm
    Badger, Stephen
    Bedenis, Rachel
    Blair, Paul H.
    Ellis, Peter
    Kee, Frank
    Harkin, Denis W.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2014, (07):
  • [28] Abdominal Compartment Syndrome After Endovascular Repair of Ruptured Abdominal Aortic Aneurysms: A Single-Center Experience of Total Endovascular Care for Ruptured Abdominal Aneurysms
    Horer, Tal M.
    Abu-Zidan, Fikri M.
    McGreevy, David T.
    Nilsson, Kristofer
    Gidlund, Khatereh Djavani
    JOURNAL OF ENDOVASCULAR THERAPY, 2025,
  • [29] Delayed abdominal closure for ruptured abdominal aortic aneurysm repair
    Bjorck, M.
    Steuer, J.
    Wanhainen, A.
    ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 17 (02): : 107 - 115
  • [30] Ruptured abdominal aortic aneurysm
    Sachs, T.
    Schermerhorn, M.
    MINERVA CHIRURGICA, 2010, 65 (03) : 303 - 317