Direct microfabrication using an X-ray micro-beam

被引:2
|
作者
Katoh, T
Zhang, YP
Kagoshima, Y
Tsusaka, Y
Matsui, J
机构
[1] Sumitomo Heavy Ind Ltd, Tokyo 1888585, Japan
[2] Himeji Inst Technol, Himeji, Hyogo 6791297, Japan
关键词
direct writing; micro-beam; X-ray lens; PTFE; PMMA; synchrotron radiation;
D O I
10.1016/S0924-4247(02)00011-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A micro-beam of hard X-ray (10 keV) as small as 5 mum in diameter has been generated using a single refractive lens (SRL) and been applied for direct writing, which may find possible applications in three-dimensional (3D) micro-fabrication. The refractive lenses are parabolic-shaped concave lenses with a radius of 4 pm and an aperture of 179 pm and have been produced using our high aspect-ratio techniques with synchrotron radiation (SR). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:725 / 728
页数:4
相关论文
共 50 条
  • [41] Quantitative distribution characterization of gradient composition of additive-manufactured stainless steel using micro-beam X-ray fluorescence
    Li, Dongling
    Shen, Xuejing
    Yang, Haiou
    Liu, Zong-xin
    Zhao, Lei
    Wang, Haizhou
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 183
  • [42] X-ray micro radiography using beam hardening correction
    Vavrik, Daniel
    Holy, Tomas
    Jakubek, Jan
    Pospisil, Stanislav
    Vykydal, Zdenek
    Dammer, Jiri
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2989 - 2992
  • [43] Direct deconvolution approach for depth profiling of element concentrations in multi-layered materials by confocal micro-beam X-ray fluorescence spectrometry
    Wrobel, Pawel
    Czyzycki, Mateusz
    TALANTA, 2013, 113 : 62 - 67
  • [44] X-Ray Micro-Beam Diffraction Measurement of the Effect of Thermal Cycling on Stress in Cu TSV: A Comparative Study
    Okoro, Chukwudi
    Leyine, Lyle E.
    Xu, Ruqing
    Hummler, Klaus
    Obeng, Yaw
    2014 IEEE 64TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2014, : 1648 - 1651
  • [45] Control and Data Acquisition System for Hard X-Ray Micro-Beam Grazing Incident Experiment and Its Application
    Lan Xu-ying
    He Shang-ming
    Zheng Yi
    Li Ai-guo
    Wang Jie
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (09) : 2794 - 2799
  • [46] Application of Confocal Micro-Beam X-Ray Fluorescence in Nondestructive Scanning Analysis of the Distribution of Elements in a Single Hair
    Liu He-he
    Liu Zhi-guo
    Sun Tian-xi
    Peng Song
    Zhao Wei-gang
    Sun Wei-yuan
    Li Yu-de
    Lin Xiao-yan
    Zhao Guang-cui
    Luo Ping
    Ding Xun-liang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (11) : 3153 - 3156
  • [47] Impurities in multicrystalline silicon wafers for solar cells detected by synchrotron micro-beam X-ray fluorescence analysis
    Buzanich, Guenter
    Radtke, Martin
    Reinholz, Uwe
    Riesemeier, Heinrich
    Thuenemann, Andreas F.
    Streli, Christina
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (11) : 1875 - 1881
  • [48] Structural analysis of ELO-GaN grown on sapphire using the x-ray micro-beam of an 8-GeV storage ring
    Miyajima, Takao
    Takeda, Shingo
    Kurihara, Hideaki
    Watanabe, Kyoko
    Kato, Madomi
    Hara, Nobuhide
    Tsusaka, Yoshiyuki
    Matsui, Junji
    Kudo, Yoshihiro
    Tomiya, Shigetaka
    Goto, Shu
    Ikeda, Masao
    Narui, Hironobu
    GAN, AIN, INN AND RELATED MATERIALS, 2006, 892 : 519 - 530
  • [49] MICRO-BEAM CHARACTERIZATION OF MATERIALS USING SYNCHROTRON X-RADIATION
    STOCK, SR
    JOURNAL OF METALS, 1987, 39 (07): : A65 - A65
  • [50] Direct observation of indium compositional fluctuation in GaInN/GaN multi-quantum wells using an X-ray micro-beam from the 8-GeV storage ring
    Miyajima, Takao
    Uemura, Shigeaki
    Kudo, Yoshihiro
    Terada, Yasuko
    Fuutagawa, Noriyuki
    PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 5, NO 6, 2008, 5 (06): : 2222 - +