Salivary testosterone measurement by liquid chromatography tandem mass spectrometry in adult males and females

被引:72
作者
Keevil, B. G. [1 ]
MacDonald, P. [1 ]
Macdowall, W. [2 ]
Lee, D. M. [3 ]
Wu, F. C. W. [3 ]
机构
[1] Univ S Manchester Hosp, Dept Clin Biochem, Manchester M23 9LT, Lancs, England
[2] London Sch Hyg & Trop Med, Dept Social & Environm Hlth Res, Ctr Sexual & Reprod Hlth Res, London WC1, England
[3] Univ Manchester, Manchester Acad Hlth Sci Ctr, Manchester Ctr Endocrinol & Diabet, Androl Res Unit, Manchester, Lancs, England
关键词
evaluation of new methods; Steroid hormones; salivary analytes; mass spectrometry; laboratory methods; MALE HYPOGONADISM; SERUM; RELIABILITY; BIOMARKERS; DIAGNOSIS; ACCURACY; CORTISOL;
D O I
10.1177/0004563213506412
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Salivary testosterone (Sal-T) may be a useful surrogate of serum free testosterone. The study aims were to use a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) assay to determine whether Sal-T concentrations accurately reflect Sal-T concentrations in both sexes and to investigate practical aspects of sample collection. Methods Saliva and serum samples were collected in 104 male and 91 female subjects. A more sensitive LC-MS/MS assay was developed to enable Sal-T quantitation in the low concentrations found in females. Saliva (200 mu L) was extracted with 1 mL of methyl-tert-butyl ether following the addition of D5-testosterone. Quantitation was performed using a Waters TQ-S mass spectrometer. Results The assay achieved a lower limit of quantification of 5 pmol/L, sufficiently sensitive to measure testosterone in female saliva. Sal-T showed a diurnal variation but samples taken at weekly and monthly intervals showed no significant differences. Sal-T was stable at ambient temperature for up to 5 days, after freeze-thawing and 3 years frozen storage. Reference intervals for Sal-T were 93-378 pmol/L in males and 5-46 pmol/L in females. Sal-T correlated significantly with serum calculated free-T in males (r = 0.71, P < 0.001) and in females (r = 0.39, P < 0.001). Conclusions These results confirm that testosterone can be reliably and accurately measured by LC-MS/MS in both adult male and female saliva samples. These results lay the foundation for further exploration of the clinical application of Sal- T as a reliable alternative to serum testosterone in the diagnosis and management of androgen disorders and assessment of androgen status in clinical research.
引用
收藏
页码:368 / 378
页数:11
相关论文
共 19 条
[1]   Salivary testosterone: a reliable approach to the diagnosis of male hypogonadism [J].
Arregger, Alejandro L. ;
Contreras, Liliana N. ;
Tumilasci, Omar R. ;
Aquilano, Daniel R. ;
Cardoso, Estela M. L. .
CLINICAL ENDOCRINOLOGY, 2007, 67 (05) :656-662
[2]  
DABBS JM, 1995, CLIN CHEM, V41, P1581
[3]  
FULTON A, 1989, CLIN CHEM, V35, P641
[4]   Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry [J].
Gallagher, L. M. ;
Owen, L. J. ;
Keevil, B. G. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 :48-56
[5]   Integration of salivary biomarkers into developmental and behaviorally-oriented research: Problems and solutions for collecting specimens [J].
Granger, Douglas A. ;
Kivlighan, Katie T. ;
Fortunato, Christine ;
Harmon, Amanda G. ;
Hibel, Leah C. ;
Schwartz, Eve B. ;
Whembolua, Guy-Lucien .
PHYSIOLOGY & BEHAVIOR, 2007, 92 (04) :583-590
[6]   Current Status of Salivary Hormone Analysis [J].
Groeschl, Michael .
CLINICAL CHEMISTRY, 2008, 54 (11) :1759-1769
[7]   Influence of commercial collection devices for saliva on the reliability of salivary steroids analysis [J].
Groeschl, Michael ;
Rauh, Manfred .
STEROIDS, 2006, 71 (13-14) :1097-1100
[8]   Accuracy of calculated free testosterone differs between equations and depends on gender and SHBG concentration [J].
Hackbarth, Jennifer S. ;
Hoyne, Jonathan B. ;
Grebe, Stefan K. ;
Singh, Ravinder J. .
STEROIDS, 2011, 76 (1-2) :48-55
[9]   A Liquid Chromatography-Tandem Mass Spectrometry Method for Salivary Testosterone with Adult Male Reference Interval Determination [J].
Macdonald, Philip R. ;
Owen, Laura J. ;
Wu, Frederick C. ;
Macdowall, Wendy ;
Keevil, Brian G. .
CLINICAL CHEMISTRY, 2011, 57 (05) :774-775
[10]   Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS) Assay for Simultaneous Measurement of Salivary Testosterone and Cortisol in Healthy Men for Utilization in the Diagnosis of Late-onset Hypogonadism in Males [J].
Matsui, Futoshi ;
Koh, Eitetsu ;
Yamamoto, Kenrou ;
Sugimoto, Kazuhiro ;
Sin, Ho-Su ;
Maeda, Yuji ;
Honma, Seijiro ;
Namiki, Mikio .
ENDOCRINE JOURNAL, 2009, 56 (09) :1083-1093