Salivary testosterone measurement by liquid chromatography tandem mass spectrometry in adult males and females

被引:69
作者
Keevil, B. G. [1 ]
MacDonald, P. [1 ]
Macdowall, W. [2 ]
Lee, D. M. [3 ]
Wu, F. C. W. [3 ]
机构
[1] Univ S Manchester Hosp, Dept Clin Biochem, Manchester M23 9LT, Lancs, England
[2] London Sch Hyg & Trop Med, Dept Social & Environm Hlth Res, Ctr Sexual & Reprod Hlth Res, London WC1, England
[3] Univ Manchester, Manchester Acad Hlth Sci Ctr, Manchester Ctr Endocrinol & Diabet, Androl Res Unit, Manchester, Lancs, England
关键词
evaluation of new methods; Steroid hormones; salivary analytes; mass spectrometry; laboratory methods; MALE HYPOGONADISM; SERUM; RELIABILITY; BIOMARKERS; DIAGNOSIS; ACCURACY; CORTISOL;
D O I
10.1177/0004563213506412
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Salivary testosterone (Sal-T) may be a useful surrogate of serum free testosterone. The study aims were to use a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) assay to determine whether Sal-T concentrations accurately reflect Sal-T concentrations in both sexes and to investigate practical aspects of sample collection. Methods Saliva and serum samples were collected in 104 male and 91 female subjects. A more sensitive LC-MS/MS assay was developed to enable Sal-T quantitation in the low concentrations found in females. Saliva (200 mu L) was extracted with 1 mL of methyl-tert-butyl ether following the addition of D5-testosterone. Quantitation was performed using a Waters TQ-S mass spectrometer. Results The assay achieved a lower limit of quantification of 5 pmol/L, sufficiently sensitive to measure testosterone in female saliva. Sal-T showed a diurnal variation but samples taken at weekly and monthly intervals showed no significant differences. Sal-T was stable at ambient temperature for up to 5 days, after freeze-thawing and 3 years frozen storage. Reference intervals for Sal-T were 93-378 pmol/L in males and 5-46 pmol/L in females. Sal-T correlated significantly with serum calculated free-T in males (r = 0.71, P < 0.001) and in females (r = 0.39, P < 0.001). Conclusions These results confirm that testosterone can be reliably and accurately measured by LC-MS/MS in both adult male and female saliva samples. These results lay the foundation for further exploration of the clinical application of Sal- T as a reliable alternative to serum testosterone in the diagnosis and management of androgen disorders and assessment of androgen status in clinical research.
引用
收藏
页码:368 / 378
页数:11
相关论文
共 19 条
  • [1] Salivary testosterone: a reliable approach to the diagnosis of male hypogonadism
    Arregger, Alejandro L.
    Contreras, Liliana N.
    Tumilasci, Omar R.
    Aquilano, Daniel R.
    Cardoso, Estela M. L.
    [J]. CLINICAL ENDOCRINOLOGY, 2007, 67 (05) : 656 - 662
  • [2] DABBS JM, 1995, CLIN CHEM, V41, P1581
  • [3] FULTON A, 1989, CLIN CHEM, V35, P641
  • [4] Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry
    Gallagher, L. M.
    Owen, L. J.
    Keevil, B. G.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 : 48 - 56
  • [5] Integration of salivary biomarkers into developmental and behaviorally-oriented research: Problems and solutions for collecting specimens
    Granger, Douglas A.
    Kivlighan, Katie T.
    Fortunato, Christine
    Harmon, Amanda G.
    Hibel, Leah C.
    Schwartz, Eve B.
    Whembolua, Guy-Lucien
    [J]. PHYSIOLOGY & BEHAVIOR, 2007, 92 (04) : 583 - 590
  • [6] Current Status of Salivary Hormone Analysis
    Groeschl, Michael
    [J]. CLINICAL CHEMISTRY, 2008, 54 (11) : 1759 - 1769
  • [7] Influence of commercial collection devices for saliva on the reliability of salivary steroids analysis
    Groeschl, Michael
    Rauh, Manfred
    [J]. STEROIDS, 2006, 71 (13-14) : 1097 - 1100
  • [8] Accuracy of calculated free testosterone differs between equations and depends on gender and SHBG concentration
    Hackbarth, Jennifer S.
    Hoyne, Jonathan B.
    Grebe, Stefan K.
    Singh, Ravinder J.
    [J]. STEROIDS, 2011, 76 (1-2) : 48 - 55
  • [9] A Liquid Chromatography-Tandem Mass Spectrometry Method for Salivary Testosterone with Adult Male Reference Interval Determination
    Macdonald, Philip R.
    Owen, Laura J.
    Wu, Frederick C.
    Macdowall, Wendy
    Keevil, Brian G.
    [J]. CLINICAL CHEMISTRY, 2011, 57 (05) : 774 - 775
  • [10] Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS) Assay for Simultaneous Measurement of Salivary Testosterone and Cortisol in Healthy Men for Utilization in the Diagnosis of Late-onset Hypogonadism in Males
    Matsui, Futoshi
    Koh, Eitetsu
    Yamamoto, Kenrou
    Sugimoto, Kazuhiro
    Sin, Ho-Su
    Maeda, Yuji
    Honma, Seijiro
    Namiki, Mikio
    [J]. ENDOCRINE JOURNAL, 2009, 56 (09) : 1083 - 1093