Magnetic Resonance Sialography Findings of Submandibular Ducts Imaging

被引:19
作者
Erdogan, Nezahat Karaca [1 ]
Altay, Canan [2 ]
Ozenler, Nesibe [3 ]
Bozkurt, Tugba [1 ]
Uluc, Engin [1 ]
Mete, Berna Dirim [1 ]
Ozdemir, Ismail [4 ]
机构
[1] Izmir Ataturk Res & Training Hosp, Dept Radiol, TR-35360 Izmir, Turkey
[2] Dokuz Eylul Univ, Sch Med, Dept Radiol, TR-35340 Izmir, Turkey
[3] Balikesir Ataturk State Hosp, Dept Radiol, TR-10100 Balikesir, Turkey
[4] Universal Ege Hlth Hosp, TR-35220 Izmir, Turkey
关键词
MR SIALOGRAPHY; CONVENTIONAL SIALOGRAPHY; SIALOLITHIASIS;
D O I
10.1155/2013/417052
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. We aimed to assess the problem solving capability of magnetic resonance sialography (MR sialography), a noninvasive method for imaging submandibular gland ducts and determining duct-related pathologies, by comparing diseased and healthy cases. Materials and Methods. We conducted radiological assessment on a total of 60 submandibular glands (mean age 44.7) in 20 cases and 10 volunteers. MR sialography examinations were conducted with single-shot fast spin-echo sequence by using a surface coil placed on the submandibular gland. Each gland was evaluated in terms of the length, width and stricture of the main duct, as well as the difference between the intraparenchymal duct width, and the main duct width. Statistical analysis was performed. Results. In the MR sialography the primary duct mean length was determined as 51 mm (40-57 mm) in all submandibular glands. On the MR sialography imaging, the visualization ratio of the ductal system of submandibular gland was evaluated in the cases and volunteers. Conclusion. MR sialography is an effective and a noninvasive method in imaging submandibular gland ducts, demonstrating the presence, location and degree of stricture/dilatation, and elucidating the disease etiology.
引用
收藏
页数:6
相关论文
共 16 条
[1]   Sialolithiasis and salivary ductal stenosis: Diagnostic accuracy of MR sialography with a three-dimensional extended-phase conjugate-symmetry rapid spin-echo sequence [J].
Becker, M ;
Marchal, F ;
Becker, CD ;
Dulguerov, P ;
Georgakopoulos, G ;
Lehmann, W ;
Terrier, F .
RADIOLOGY, 2000, 217 (02) :347-358
[2]  
Erdogan N., 2008, TURKIYE KLIN J RADIO, V1, P66
[3]   DIAGNOSING SALIVARY STONES [J].
HARING, JI .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1991, 122 (06) :75-76
[4]   MR sialography: the effect of a sialogogue and ductal occlusion in volunteers [J].
Hugill, J. ;
Sala, E. ;
Hollingsworth, K. G. ;
Lomas, D. J. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (967) :583-586
[5]  
Jäger L, 2000, RADIOLOGY, V216, P665
[6]   Magnetic resonance sialography [J].
Jungehülsing, M ;
Fischbach, R ;
Schröder, U ;
Kugel, H ;
Damm, M ;
Eckel, HE .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 121 (04) :488-494
[7]  
Kalinowski M, 2002, AM J NEURORADIOL, V23, P1485
[8]   MR sialography - Work in progress [J].
Lomas, DJ ;
Carroll, NR ;
Johnson, G ;
Antoun, NM ;
Freer, CEL .
RADIOLOGY, 1996, 200 (01) :129-133
[9]  
Murakami R, 1998, AM J NEURORADIOL, V19, P959
[10]   Submandibular sialogram performed through a Wharton's duct fistula: Technical adaptation of conventional technique [J].
Obaid, H. ;
Sinha, R. ;
Robinson, L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (01) :56-57