The Feasibility of Classifying Breast Masses Using a Computer-Assisted Diagnosis (CAD) System Based on Ultrasound Elastography and BI-RADS Lexicon

被引:9
|
作者
Fleury, Eduardo F. C. [1 ]
Gianini, Ana Claudia [2 ]
Marcomini, Karem [3 ]
Oliveira, Vilmar [1 ]
机构
[1] Sch Med Sci Santa Casa Sao Paulo, Rua Maestro Chiaffarelli 409, Sao Paulo, SP, Brazil
[2] Inst Brasileiro Controle Canc, Sao Paulo, Brazil
[3] Univ Sao Carlos, Sao Carlos, SP, Brazil
关键词
ultrasound; elastography; breast tumors; diagnosis and examinations; mass screening; DENSITY NOTIFICATION LEGISLATION; AIDED DIAGNOSIS; CANCER; FEATURES; LESIONS; CLASSIFICATION; MAMMOGRAPHY; EXPERIENCE; IMPACT;
D O I
10.1177/1533033818763461
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives: To determine the applicability of a computer-aided diagnostic system strain elastography system for the classification of breast masses diagnosed by ultrasound and scored using the criteria proposed by the breast imaging and reporting data system ultrasound lexicon and to determine the diagnostic accuracy and interobserver variability. Methods: This prospective study was conducted between March 1, 2016, and May 30, 2016. A total of 83 breast masses subjected to percutaneous biopsy were included. Ultrasound elastography images before biopsy were interpreted by 3 radiologists with and without the aid of computer-aided diagnostic system for strain elastography. The parameters evaluated by each radiologist results were sensitivity, specificity, and diagnostic accuracy, with and without computer-aided diagnostic system for strain elastography. Interobserver variability was assessed using a weighted kappa test and an intraclass correlation coefficient. The areas under the receiver operating characteristic curves were also calculated. Results: The areas under the receiver operating characteristic curve were 0.835, 0.801, and 0.765 for readers 1, 2, and 3, respectively, without computer-aided diagnostic system for strain elastography, and 0.900, 0.926, and 0.868, respectively, with computer-aided diagnostic system for strain elastography. The intraclass correlation coefficient between the 3 readers was 0.6713 without computer-aided diagnostic system for strain elastography and 0.811 with computer-aided diagnostic system for strain elastography. Conclusion: The proposed computer-aided diagnostic system for strain elastography system has the potential to improve the diagnostic performance of radiologists in breast examination using ultrasound associated with elastography.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A computer-aided diagnosis system using artificial intelligence for the diagnosis and characterization of breast masses on ultrasound Added value for the inexperienced breast radiologist
    Park, Hee Jeong
    Kim, Sun Mi
    Yun, Bo La
    Jang, Mijung
    Kim, Bohyoung
    Jang, Ja Yoon
    Lee, Jong Yoon
    Lee, Soo Hyun
    MEDICINE, 2019, 98 (03)
  • [42] A novel classifier model for mass classification using BI-RADS category in ultrasound images based on Type-2 fuzzy inference system
    Uzunhisarcikli, Esma
    Goreke, Volkan
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2018, 43 (09):
  • [43] Discrimination of benign and malignant solid breast masses using deep residual learning-based bimodal computer-aided diagnosis system
    Assari, Zahra
    Mahloojifar, Ali
    Ahmadinejad, Nasrin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 73
  • [44] Computer-assisted diagnosis for axillary lymph node metastasis of early breast cancer based on transformer with dual-modal adaptive mid-term fusion using ultrasound elastography
    Gong, Chihao
    Wu, Yinglan
    Zhang, Guangyuan
    Liu, Xuan
    Zhu, Xiaoyao
    Cai, Nian
    Li, Jian
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2025, 119
  • [45] Added value of deep learning-based computer-aided diagnosis and shear wave elastography to b-mode ultrasound for evaluation of breast masses detected by screening ultrasound
    Kim, Min Young
    Kim, Soo-Yeon
    Kim, Yeon Soo
    Kim, Eun Sil
    Chang, Jung Min
    MEDICINE, 2021, 100 (31) : E26823
  • [46] Downgrading Breast Imaging Reporting and Data System categories in ultrasound using strain elastography and computer-aided diagnosis system: a multicenter, prospective study
    Du, Yu
    Ma, Ji
    Wu, Tingting
    Li, Fang
    Pan, Jiazhen
    Du, Liwen
    Zhang, Manqi
    Diao, Xuehong
    Wu, Rong
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1162) : 1653 - 1660
  • [47] Variability in Observer Performance Between Faculty Members and Residents Using Breast Imaging Reporting and Data System (BI-RADS)-Ultrasound, Fifth Edition (2013)
    Lee, Youn Joo
    Choi, So Young
    Kim, Kyu Sun
    Yang, Po Song
    IRANIAN JOURNAL OF RADIOLOGY, 2016, 13 (03)
  • [48] Comprehensive Risk System Based on Shear Wave Elastography and BI-RADS Categories in Assessing Axillary Lymph Node Metastasis of Invasive Breast Cancer-A Multicenter Study
    Zhang, Huiting
    Dong, Yijie
    Jia, Xiaohong
    Zhang, Jingwen
    Li, Zhiyao
    Chuan, Zhirui
    Xu, Yanjun
    Hu, Bin
    Huang, Yunxia
    Chang, Cai
    Xu, Jinfeng
    Dong, Fajin
    Xia, Xiaona
    Wu, Chengrong
    Hu, Wenjia
    Wu, Gang
    Li, Qiaoying
    Chen, Qin
    Deng, Wanyue
    Jiang, Qiongchao
    Mou, Yonglin
    Yan, Huannan
    Xu, Xiaojing
    Yan, Hongju
    Zhou, Ping
    Shao, Yang
    Cui, Ligang
    He, Ping
    Qian, Linxue
    Liu, Jinping
    Shi, Liying
    Zhao, Yanan
    Xu, Yongyuan
    Song, Yanyan
    Zhan, Weiwei
    Zhou, Jianqiao
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [49] A novel classifier model for mass classification using BI-RADS category in ultrasound images based on Type-2 fuzzy inference system
    ESMA UZUNHISARCIKLI
    VOLKAN GOREKE
    Sādhanā, 2018, 43
  • [50] Evaluation of the predictive ability of ultrasound-based assessment of breast cancer using BI-RADS natural language reporting against commercial transcriptome-based tests
    Jamshidii, Neema
    Chang, Jason
    Mock, Kyle
    Nguyen, Brian
    Dauphine, Christine
    Kuo, Michael D.
    PLOS ONE, 2020, 15 (01):