The Feasibility of Classifying Breast Masses Using a Computer-Assisted Diagnosis (CAD) System Based on Ultrasound Elastography and BI-RADS Lexicon

被引:9
|
作者
Fleury, Eduardo F. C. [1 ]
Gianini, Ana Claudia [2 ]
Marcomini, Karem [3 ]
Oliveira, Vilmar [1 ]
机构
[1] Sch Med Sci Santa Casa Sao Paulo, Rua Maestro Chiaffarelli 409, Sao Paulo, SP, Brazil
[2] Inst Brasileiro Controle Canc, Sao Paulo, Brazil
[3] Univ Sao Carlos, Sao Carlos, SP, Brazil
关键词
ultrasound; elastography; breast tumors; diagnosis and examinations; mass screening; DENSITY NOTIFICATION LEGISLATION; AIDED DIAGNOSIS; CANCER; FEATURES; LESIONS; CLASSIFICATION; MAMMOGRAPHY; EXPERIENCE; IMPACT;
D O I
10.1177/1533033818763461
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives: To determine the applicability of a computer-aided diagnostic system strain elastography system for the classification of breast masses diagnosed by ultrasound and scored using the criteria proposed by the breast imaging and reporting data system ultrasound lexicon and to determine the diagnostic accuracy and interobserver variability. Methods: This prospective study was conducted between March 1, 2016, and May 30, 2016. A total of 83 breast masses subjected to percutaneous biopsy were included. Ultrasound elastography images before biopsy were interpreted by 3 radiologists with and without the aid of computer-aided diagnostic system for strain elastography. The parameters evaluated by each radiologist results were sensitivity, specificity, and diagnostic accuracy, with and without computer-aided diagnostic system for strain elastography. Interobserver variability was assessed using a weighted kappa test and an intraclass correlation coefficient. The areas under the receiver operating characteristic curves were also calculated. Results: The areas under the receiver operating characteristic curve were 0.835, 0.801, and 0.765 for readers 1, 2, and 3, respectively, without computer-aided diagnostic system for strain elastography, and 0.900, 0.926, and 0.868, respectively, with computer-aided diagnostic system for strain elastography. The intraclass correlation coefficient between the 3 readers was 0.6713 without computer-aided diagnostic system for strain elastography and 0.811 with computer-aided diagnostic system for strain elastography. Conclusion: The proposed computer-aided diagnostic system for strain elastography system has the potential to improve the diagnostic performance of radiologists in breast examination using ultrasound associated with elastography.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A computer-aided diagnosis system for breast ultrasound based on weighted BI-RADS classes
    Rodriguez-Cristerna, Arturo
    Gomez-Flores, Wilfrido
    de Albuquerque Pereira, Wagner Coelho
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 153 : 33 - 40
  • [2] Interobserver variability of ultrasound elastography and the ultrasound BI-RADS lexicon of breast lesions
    Park, Chang Suk
    Kim, Sung Hun
    Jung, Na Young
    Choi, Jae Jung
    Kang, Bong Joo
    Jung, Hyun Seouk
    BREAST CANCER, 2015, 22 (02) : 153 - 160
  • [3] Interobserver variability of ultrasound elastography and the ultrasound BI-RADS lexicon of breast lesions
    Chang Suk Park
    Sung Hun Kim
    Na Young Jung
    Jae Jung Choi
    Bong Joo Kang
    Hyun Seouk Jung
    Breast Cancer, 2015, 22 : 153 - 160
  • [4] Value of ultrasound elastography in diagnosis of BI-RADS 4B breast lesions based on conventional ultrasound
    Gong, Xia
    Wang, Yi
    Wu, Weihua
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (02): : 2561 - 2566
  • [5] The Breast Ultrasound Lexicon: Breast Imaging Reporting and Data System (BI-RADS)
    Sedgwick, Emily
    SEMINARS IN ROENTGENOLOGY, 2011, 46 (04) : 245 - 251
  • [6] A Practical Computer Aided Diagnosis System for Breast Ultrasound Classifying Lesions into the ACR BI-RADS Assessment
    Su, Hsin-Ya
    Lien, Chung-Yueh
    Huang, Pai-Jung
    Chu, Woei-Chyn
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (03) : 426 - 436
  • [7] Breast ultrasound computer-aided diagnosis using BI-RADS features
    Shen, Wei-Chih
    Chang, Ruey-Feng
    Moon, Woo Kyung
    Chou, Yi-Hong
    Huang, Chiun-Sheng
    ACADEMIC RADIOLOGY, 2007, 14 (08) : 928 - 939
  • [8] Combined Use of Shear Wave Elastography, Microvascular Doppler Ultrasound Technique, and BI-RADS for the Differentiation of Benign and Malignant Breast Masses
    Wang, Bin
    Chen, Yu-Yuan
    Yang, Si
    Chen, Zhen-Wen
    Luo, Jia
    Cui, Xin-Wu
    Dietrich, Christoph F.
    Yi, Ai-jiao
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [9] Novel approach in the evaluation of ultrasound BI-RADS 3 & 4 breast masses with a combination method of elastography & Doppler
    Reghunath, Anjuna
    Mittal, Mahesh Kumar
    Chintamani, Chintamani
    Prasad, Rajni
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2021, 154 (02) : 355 - 366
  • [10] Computer-aided diagnosis of breast masses using quantified BI-RADS findings
    Moon, Woo Kyung
    Lo, Chung-Ming
    Cho, Nariya
    Chang, Jung Min
    Huang, Chiun-Sheng
    Chen, Jeon-Hor
    Chang, Ruey-Feng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 111 (01) : 84 - 92