Estimation of Values below the Limit of Detection of a Contemporary Sensitive Troponin I Assay Improves Diagnosis of Acute Myocardial Infarction

被引:11
作者
Boeckel, Jes-Niels [1 ,8 ]
Palapies, Lars [2 ]
Zeller, Tanja [3 ,4 ]
Reis, Sophia M. [2 ]
von Jeinsen, Beatrice [2 ]
Tzikas, Stergios [7 ,10 ]
Bickel, Christoph [9 ]
Baldus, Stephan [6 ]
Blankenberg, Stefan [3 ,4 ]
Muenzel, Thomas [7 ,8 ]
Zeiher, Andreas M. [2 ,8 ]
Lackner, Karl J. [5 ]
Keller, Till [2 ,8 ]
机构
[1] Goethe Univ Frankfurt, Ctr Mol Med, Inst Cardiovasc Regenerat, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Div Cardiol, Dept Med 3, D-60590 Frankfurt, Germany
[3] Univ Heart Ctr Hamburg, Clin Gen & Intervent Cardiol, Hamburg, Germany
[4] DZHK German Ctr Cardiovasc Res, Kiel, Germany
[5] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Inst Clin Chem & Lab Med, D-55122 Mainz, Germany
[6] Univ Cologne, Ctr Heart, D-50931 Cologne, Germany
[7] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Med 2, D-55122 Mainz, Germany
[8] DZHK German Ctr Cardiovasc Res, Rhein, Germany
[9] Fed Armed Forces Hosp, Dept Internal Med, Koblenz, Germany
[10] Aristotle Univ Thessaloniki, Ippokrateio Hosp, Dept Cardiol 3, GR-54006 Thessaloniki, Greece
关键词
RISK; TIME;
D O I
10.1373/clinchem.2015.238949
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: The limit of detection (LoD) is the minimal amount of a substance that can be consistently detected. In the diagnosis of acute myocardial infarction (AMI) many patients present with troponin concentrations below the LoD of contemporary sensitive cardiac troponin I (cs-cTnI) assays. These censored values below the LoD influence the diagnostic performance of these assays compared to highly sensitive cTnI (hs-cTnI) assays. Therefore we assessed the impact of a new approach for interpolation of the left-censored data of a cs-cTnI assay in the evaluation of patients with suspected AMI. METHODS: Our posthoc analysis used a real world cohort of 1818 patients with suspected MI. Data on cs-cTnI was available in 1786 patients. As a comparator the hs-cTnI version of the assay was used. To reconstruct quantities below the LoD of the cs-cTnI assay, a gamma regression approach incorporating the GRACE (Global Registry of Acute Coronary Events) score variables was used. RESULTS: Censoring of cs-cTnI data below the LoD yielded weaker diagnostic information [area under the curve (AUC), 0.781; 95% CI, 0.731-0.831] regarding AMI compared to the hs-cTnI assay (AUC, 0.949; CI, 0.936-0.961). Use of our model to estimate cs-cTnI values below the LoD showed an AUC improvement to 0.921 (CI, 0.902-0.940). The cs-cTnI LoD concentration had a negative predictive value (NPV) of 0.950. An estimated concentration that was to be undercut by 25% of patients presenting with suspected AMI was associated with an improvement of the NPV to 0.979. CONCLUSIONS: Estimation of values below the LoD of a cs-cTnI assay with this new approach improves the diagnostic performance in evaluation of patients with suspected AMI. (C) 2015 American Association for Clinical Chemistry
引用
收藏
页码:1197 / 1206
页数:10
相关论文
共 27 条
[11]   Rapid Exclusion of Acute Myocardial Infarction in Patients With Undetectable Troponin Using a High-Sensitivity Assay [J].
Body, Richard ;
Carley, Simon ;
McDowell, Garry ;
Jaffe, Allan S. ;
France, Michael ;
Cruickshank, Kennedy ;
Wibberley, Christopher ;
Nuttall, Michelle ;
Mackway-Jones, Kevin .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (13) :1333-1339
[12]   A Distribution-Based Multiple Imputation Method for Handling Bivariate Pesticide Data with Values below the Limit of Detection [J].
Chen, Haiying ;
Quandt, Sara A. ;
Grzywacz, Joseph G. ;
Arcury, Thomas A. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2011, 119 (03) :351-356
[13]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[14]  
EPA US, 2000, QAG9 US EPA
[15]  
Falk M., 2002, FDN STAT ANAL APPL S, DOI [10.1007/978-3-0348-8195-1, DOI 10.1007/978-3-0348-8195-1]
[16]   Prediction of risk of death and myocardial infarction in the six months after presentation with acute coronary syndrome: prospective multinational observational study (GRACE) [J].
Fox, Keith A. A. ;
Dabbous, Omar H. ;
Goldberg, Robert J. ;
Pieper, Karen S. ;
Eagle, Kim A. ;
Van de Werf, Frans ;
Avezum, Alvaro ;
Goodman, Shaun G. ;
Flather, Marcus D. ;
Anderson, Frederick A., Jr. ;
Granger, Christopher B. .
BMJ-BRITISH MEDICAL JOURNAL, 2006, 333 (7578) :1091-1094
[17]   Much Ado About Next to Nothing: Incorporating Nondetects in Science [J].
Helsel, Dennis .
ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (03) :257-262
[18]   More than obvious: Better methods for interpreting nondetect data [J].
Helsel, DR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (20) :419A-423A
[19]   ENZYME LINKED IMMUNO ASSAY OF CARDIAC TROPONIN-T FOR THE DETECTION OF ACUTE MYOCARDIAL-INFARCTION IN PATIENTS [J].
KATUS, HA ;
REMPPIS, A ;
LOOSER, S ;
HALLERMEIER, K ;
SCHEFFOLD, T ;
KUBLER, W .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1989, 21 (12) :1349-1353
[20]   Serial Changes in Highly Sensitive Troponin I Assay and Early Diagnosis of Myocardial Infarction [J].
Keller, Till ;
Zeller, Tanja ;
Ojeda, Francisco ;
Tzikas, Stergios ;
Lillpopp, Lars ;
Sinning, Christoph ;
Wild, Philipp ;
Genth-Zotz, Sabine ;
Warnholtz, Ascan ;
Giannitsis, Evangelos ;
Moeckel, Martin ;
Bickel, Christoph ;
Peetz, Dirk ;
Lackner, Karl ;
Baldus, Stephan ;
Muenzel, Thomas ;
Blankenberg, Stefan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2011, 306 (24) :2684-2693