A Resonant Current-Mode Wireless Power Receiver and Battery Charger With-32 dBm Sensitivity for Implantable Systems

被引:44
作者
Choi, Myungjoon [1 ]
Jang, Taekwang [1 ]
Jeong, Junwon [1 ]
Jeong, Seokhyeon [1 ]
Blaauw, David [1 ]
Sylvester, Dennis [1 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48105 USA
关键词
Current mode; implantable system; inductor-based harvesting; internet of things; RF harvesting; wireless power transfer; CMOS;
D O I
10.1109/JSSC.2016.2598224
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wireless power transfer for implantable systems must harvest very low power levels due to low incident power on human tissues and a small receiver coil size. This work proposes resonant current-mode charging to reduce minimum harvestable input power and increase power efficiency at low input power levels. Avoiding rectification and voltage regulation from conventional voltage-mode methods, this work resonates an LC tank for multiple cycles to build up energy, then directly charges a battery with inductor current. A prototype is fabricated in 0.18 mu m CMOS technology. Minimum harvestable input power is 600 nW and maximum power efficiency is 67.6% at 4.2 mu W input power. Power transmission through bovine tissue is measured to have negligible efficiency loss, making this technique amenable to implantable applications.
引用
收藏
页码:2880 / 2892
页数:13
相关论文
共 23 条
[1]  
[Anonymous], 2013, IEEE INT SOL STAT CI
[2]  
[Anonymous], 2007, TS H LITH RECH BATT
[3]  
[Anonymous], 2005, MAN LITH COIN BATT M
[4]   An implantable wireless neural interface for recording cortical circuit dynamics in moving primates [J].
Borton, David A. ;
Yin, Ming ;
Aceros, Juan ;
Nurmikko, Arto .
JOURNAL OF NEURAL ENGINEERING, 2013, 10 (02)
[5]  
Chen PH, 2012, ASIA S PACIF DES AUT, P469, DOI 10.1109/ASPDAC.2012.6164994
[6]  
Choi JH, 2013, ISSCC DIG TECH PAP I, V56, P64, DOI 10.1109/ISSCC.2013.6487638
[7]  
Choi M, 2016, ISSCC DIG TECH PAP I, V59, P372
[8]  
Freitas R.A., 1999, Nanomedicine: Basic Capabilities, V1
[9]   Circuits for a Cubic-Millimeter Energy-Autonomous Wireless Intraocular Pressure Monitor [J].
Ghaed, Mohammad Hassan ;
Chen, Gregory ;
Razi-ul Haque ;
Wieckowski, Michael ;
Kim, Yejoong ;
Kim, Gyouho ;
Lee, Yoonmyung ;
Lee, Inhee ;
Fick, David ;
Kim, Daeyeon ;
Seok, Mingoo ;
Wise, Kensall D. ;
Blaauw, David ;
Sylvester, Dennis .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2013, 60 (12) :3152-3162
[10]  
Kang J, 2016, ISSCC DIG TECH PAP I, V59, P374, DOI 10.1109/ISSCC.2016.7418063