Dynamic autoregulation of cerebral blood flow measured non-invasively with fast diffuse correlation spectroscopy

被引:50
作者
Parthasarathy, Ashwin B. [1 ,2 ]
Gannon, Kimberly P. [3 ]
Baker, Wesley B. [4 ]
Favilla, Christopher G. [3 ]
Balu, Ramani [3 ]
Kasner, Scott E. [3 ]
Yodh, Arjun G. [1 ]
Detre, John A. [3 ]
Mullen, Michael T. [3 ]
机构
[1] Univ Penn, Dept Phys & Astron, Philadelphia, PA 19104 USA
[2] Univ S Florida, Dept Elect Engn, Tampa, FL USA
[3] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[4] Univ Penn, Dept Anesthesiol & Crit Care, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
Cerebral blood flow; cerebral autoregulation; noninvasive monitoring; intrinsic optical imaging; neurocritical care; NEAR-INFRARED SPECTROSCOPY; ACUTE ISCHEMIC-STROKE; CEREBROVASCULAR PRESSURE REACTIVITY; TIME-DOMAIN; TRANSCRANIAL DOPPLER; PERFUSION; HEMODYNAMICS; HEMORRHAGE; YIELD;
D O I
10.1177/0271678X17747833
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cerebral autoregulation (CA) maintains cerebral blood flow (CBF) in the presence of systemic blood pressure changes. Brain injury can cause loss of CA and resulting dysregulation of CBF, and the degree of CA impairment is a functional indicator of cerebral tissue health. Here, we demonstrate a new approach to noninvasively estimate cerebral autoregulation in healthy adult volunteers. The approach employs pulsatile CBF measurements obtained using high-speed diffuse correlation spectroscopy (DCS). Rapid thigh-cuff deflation initiates a chain of responses that permits estimation of rates of dynamic autoregulation in the cerebral microvasculature. The regulation rate estimated with DCS in the microvasculature (median: 0.26 s(-1), inter quartile range: 0.19 s(-1)) agrees well (R=0.81, slope=0.9) with regulation rates measured by transcranial Doppler ultrasound (TCD) in the proximal vasculature (median: 0.28 s(-1), inter quartile range: 0.10 s(-1)). We also obtained an index of systemic autoregulation in concurrently measured scalp microvasculature. Systemic autoregulation begins later than cerebral autoregulation and exhibited a different rate (0.55 s(-1), inter quartile range: 0.72 s(-1)). Our work demonstrates the potential of diffuse correlation spectroscopy for bedside monitoring of cerebral autoregulation in the microvasculature of patients with brain injury.
引用
收藏
页码:230 / 240
页数:11
相关论文
共 56 条
[1]   CEREBRAL AUTO-REGULATION DYNAMICS IN HUMANS [J].
AASLID, R ;
LINDEGAARD, KF ;
SORTEBERG, W ;
NORNES, H .
STROKE, 1989, 20 (01) :45-52
[2]   Yield of transcranial Doppler in acute cerebral ischemia [J].
Alexandrov, AV ;
Demchuk, AM ;
Wein, TH ;
Grotta, JC .
STROKE, 1999, 30 (08) :1604-1609
[3]   Impaired Cerebral Autoregulation Is Associated with Brain Atrophy and Worse Functional Status in Chronic Ischemic Stroke [J].
Aoi, Mikio C. ;
Hu, Kun ;
Lo, Men-Tzung ;
Selim, Magdy ;
Olufsen, Mette S. ;
Novak, Vera .
PLOS ONE, 2012, 7 (10)
[4]   Dynamic Cerebral Autoregulation Is Compromised Acutely following Mild Ischaemic Stroke but Not Transient Ischaemic Attack [J].
Atkins, Emily R. ;
Brodie, Fiona G. ;
Rafelt, Suzanne E. ;
Panerai, Ronney B. ;
Robinson, Thompson G. .
CEREBROVASCULAR DISEASES, 2010, 29 (03) :228-235
[5]   Pressure modulation algorithm to separate cerebral hemodynamic signals from extracerebral artifacts [J].
Baker, Wesley B. ;
Parthasarathy, Ashwin B. ;
Ko, Tiffany S. ;
Busch, David R. ;
Abramson, Kenneth ;
Tzeng, Shih-Yu ;
Mesquita, Rickson C. ;
Durduran, Turgut ;
Greenberg, Joel H. ;
Kung, David K. ;
Yodh, Arjun G. .
NEUROPHOTONICS, 2015, 2 (03)
[6]   Modified Beer-Lambert law for blood flow [J].
Baker, Wesley B. ;
Parthasarathy, Ashwin B. ;
Busch, David R. ;
Mesquita, Rickson C. ;
Greenberg, Joel H. ;
Yodh, A. G. .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (11) :4053-4075
[7]   Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlation [J].
Boas, DA ;
Yodh, AG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (01) :192-215
[8]   Continuous time-domain analysis of cerebrovascular autoregulation using near-infrared spectroscopy [J].
Brady, Ken M. ;
Lee, Jennifer K. ;
Kibler, Kathleen K. ;
Smielewski, Piotr ;
Czosnyka, Marek ;
Easley, R. Blaine ;
Koehler, Raymond C. ;
Shaffner, Donald H. .
STROKE, 2007, 38 (10) :2818-2825
[9]   Monitoring Cerebral Blood Flow Pressure Autoregulation in Pediatric Patients During Cardiac Surgery [J].
Brady, Ken M. ;
Mytar, Jennifer O. ;
Lee, Jennifer K. ;
Cameron, Duke E. ;
Vricella, Luca A. ;
Thompson, W. Reid ;
Hogue, Charles W. ;
Easley, R. Blaine .
STROKE, 2010, 41 (09) :1957-1962
[10]   Real-Time Continuous Monitoring of Cerebral Blood Flow Autoregulation Using Near-Infrared Spectroscopy in Patients Undergoing Cardiopulmonary Bypass [J].
Brady, Kenneth ;
Joshi, Brijen ;
Zweifel, Christian ;
Smielewski, Peter ;
Czosnyka, Marek ;
Easley, R. Blaine ;
Hogue, Charles W., Jr. .
STROKE, 2010, 41 (09) :1951-1956