High Frequency Model of Cables for Frequency Domain Analysis used for Fault Localization

被引:0
|
作者
Norouzi, Y. [1 ]
Frohne, C. [1 ]
Werle, P. [2 ]
机构
[1] Nexans Deutschland GmbH, Kabelkamp 20, D-30179 Hannover, Germany
[2] Leibniz Univ Hannover, Inst Elect Power Syst, Schering Inst, Div High Voltage Engn & Asset Management, Callinstr 25A, D-30167 Hannover, Germany
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to develop a new method for the detection and localization of faults in long cable systems, it would be beneficial to develop a numerical model for a cable in order to simulate the possible fault scenarios. In this regard, a simulation model using MATLAB / SIMULINK is established. This model provides the response and behavior of a cable system to sweep frequency signals. It is programmed for a broad range of cable parameters. To verify the simulation model, the results are compared to those experimentally measured results on a real cable. The emerging deviations in FDA response are attributed to the corresponding fault mode.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Frequency Dependent Model of Underground Cables for Harmonic Calculations in Frequency Domain
    Malekian, Kaveh
    Schmidt, Uwe
    Hoshmeh, Abudllah
    Shirvani, Ali
    2014 6TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING (ICITEE), 2014, : 271 - 277
  • [2] Frequency-domain dynamic analysis of cables
    Liu, YG
    Bergdahl, L
    ENGINEERING STRUCTURES, 1997, 19 (06) : 499 - 506
  • [3] Fault Identification and Localization of a Time-Frequency Domain Joint Impedance Spectrum of Cables Based on Deep Belief Networks
    Wan, Qingzhu
    Li, Yimeng
    Yuan, Runjiao
    Meng, Qinghai
    Li, Xiaoxue
    SENSORS, 2023, 23 (02)
  • [4] Soft fault detection in cables using the cluster time-frequency domain reflectometry
    1600, Institute of Electrical and Electronics Engineers Inc., United States (02):
  • [5] Localization and assessment of breakage defect in cables based on time-frequency domain reflectometry
    Zou, Xingyu
    Mu, Haibao
    Qu, Lanqing
    Zhang, Haotian
    Xie, Cheng
    Zhang, Guanjun
    ENERGY REPORTS, 2022, 8 : 1474 - 1481
  • [6] Fault observability analysis of analog circuits in frequency domain
    Slamani, M
    Kaminska, B
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-ANALOG AND DIGITAL SIGNAL PROCESSING, 1996, 43 (02): : 134 - 139
  • [7] A Frequency Domain Model for Beat Frequency Oscillation Analysis in Microgrid
    Yue, Xiaolong
    Boroyevich, Dushan
    Burgos, Rolando
    Zhuo, Fang
    2016 18TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'16 ECCE EUROPE), 2016,
  • [8] A Frequency-Domain Fault Location Method for Underground Cables in MMC-HVdc Systems
    Song, Guobing
    Yan, Jifei
    Chang, Zhongxue
    Zhang, Chenhao
    Gao, Xiaoping
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [9] A fault location method for power cables using time-frequency analysis
    Kobayashi, Shin'ichi
    Morimoto, Nozomi
    Miyajima, Kazuhisa
    Hozumi, Naohiro
    ELECTRICAL ENGINEERING IN JAPAN, 2013, 182 (01) : 10 - 17
  • [10] Measurements of Characteristic Impedance of High Frequency Cables with Time Domain Reflectometry (TDR)
    Navarro, Luis
    Mayevskiy, Eugene
    Chairet, Timothy
    72ND ARFTG MICROWAVE MEASUREMENT SYMPOSIUM, 2008, : 9 - 19