Selective monitoring of acidic and basic compounds in environmental water by capsule phase microextraction using sol-gel mixed-mode sorbents followed by liquid chromatography-mass spectrometry in tandem

被引:23
作者
Carles Nadal, Joan [1 ]
Borrull, Francesc [1 ]
Furton, Kenneth G. [2 ]
Kabir, Abuzar [2 ]
Fontanals, Nuria [1 ]
Maria Marce, Rosa [1 ]
机构
[1] Univ Rovira & Virgili, Dept Analyt Chem & Organ Chem, Sescelades Campus,Marcelli Domingo 1, Tarragona 43007, Spain
[2] Florida Int Univ, Int Forens Res Inst, Dept Chem & Biochem, Miami, FL 33199 USA
关键词
Capsule phase microextraction; Mixed-mode ion-exchange; Sol-gel; Acidic analytes; Basic analytes; Environmental samples; BAR SORPTIVE EXTRACTION; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; PERSONAL CARE PRODUCTS; STIR-BAR; TRANSFORMATION PRODUCTS; ULTRAVIOLET DETECTION; POLAR; PHARMACEUTICALS; COMBINATION; METABOLITES;
D O I
10.1016/j.chroma.2020.461295
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In addition to the diverse extraction techniques available, capsule phase microextraction (CPME), which uses a microextraction capsule (MEC), has recently been introduced as a sorptive-based sample preparation technique. In this study, two different MECs (MEC--C18/SAX and MEC-C18/SCX) based on mixed-mode ion-exchange technology were synthesized and evaluated for the selective extraction of a group of ionizable compounds, including acidic and basic analytes. A sulfonic acid was used as the cation-exchange group in MEC-C18/SCX, and a quaternary amine as the anion-exchange group in MEC--C18/SAX. The extraction parameters optimized were sample pH, elution solvent, sample/elution volume and extraction/elution time. The optimized CPME method followed by LC-MS/MS was used to determine the ionizable compounds in environmental water samples, including river water and effluent wastewater, with excellent selectivity and matrix effect values below -30% (except -33% for mephedrone) and apparent recovery results ranging from 40% to 69%, except for ibuprofen (< 35%) and atenolol (< 25%). The analytical method was validated for environmental water samples, and used in the analysis of several samples in which some of the target compounds were found at ng L-1 concentration levels. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 35 条
[1]   Stir bar sorptive extraction and liquid chromatography-tandem mass spectrometry determination of polar and non-polar emerging and priority pollutants in environmental waters [J].
Aparicio, Irene ;
Martin, Julia ;
Luis Santos, Juan ;
Luis Malvar, Jose ;
Alonso, Esteban .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1500 :43-52
[2]   Development and application of a polar coating for stir bar sorptive extraction of emerging pollutants from environmental water samples [J].
Bratkowska, D. ;
Marce, R. M. ;
Cormack, P. A. G. ;
Borrull, F. ;
Fontanals, N. .
ANALYTICA CHIMICA ACTA, 2011, 706 (01) :135-142
[3]   Recent advances and trends in miniaturized sample preparation techniques [J].
da Silva Burato, Juliana Soares ;
Vargas Medina, Deyber Arley ;
de Toffoli, Ana Lucia ;
Soares Maciel, Edvaldo Vasconcelos ;
Lancas, Fernando Mauro .
JOURNAL OF SEPARATION SCIENCE, 2020, 43 (01) :202-225
[4]   Pharmaceuticals residues and xenobiotics contaminants: Occurrence, analytical techniques and sustainable alternatives for wastewater treatment [J].
de Oliveira, Milina ;
Farias Frihling, Breno Emanuel ;
Velasques, Jannaina ;
Correa Magalhaes Filho, Fernando Jorge ;
Cavalheri, Priscila Sabioni ;
Migliolo, Ludovico .
SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 705
[5]   Using a novel sol-gel stir bar sorptive extraction method for the analysis of steroid hormones in water by laser diode thermal desorption/atmospheric chemical ionization tandem mass spectrometry [J].
Duy, S. Vo ;
Fayad, P. B. ;
Barbeau, B. ;
Prevost, M. ;
Sauve, S. .
TALANTA, 2012, 101 :337-345
[6]   Overview of mixed-mode ion-exchange materials in the extraction of organic compounds [J].
Fontanals, Nuria ;
Borrull, Francesc ;
Marce, Rosa Maria .
ANALYTICA CHIMICA ACTA, 2020, 1117 :89-107
[7]   Evaluation of strong cation-exchange polymers for the determination of drugs by solid-phase extraction-liquid chromatography-tandem mass spectrometry [J].
Fontanals, Nuria ;
Miralles, Nuria ;
Abdullah, Norhayati ;
Davies, Arlene ;
Gilart, Nuria ;
Cormack, P. A. G. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1343 :55-62
[8]   Recent advances and future trends in new materials for sample preparation [J].
Fumes, Bruno Henrique ;
Silva, Meire Ribeiro ;
Andrade, Felipe Nascimento ;
Domingues Nazario, Carlos Eduardo ;
Lancas, Fernando Mauro .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2015, 71 :9-25
[9]   Monitoring of emerging pollutants in Guadiamar River basin (South of Spain): analytical method, spatial distribution and environmental risk assessment [J].
Garrido, Eva ;
Camacho-Munoz, Dolores ;
Martin, Julia ;
Santos, Antonio ;
Luis Santos, Juan ;
Aparicio, Irene ;
Alonso, Esteban .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (24) :25127-25144
[10]   Novel capsule phase microextraction in combination with high performance liquid chromatography with diode array detection for rapid monitoring of sulfonamide drugs in milk [J].
Georgiadis, Doukas-Evangelos ;
Tsalbouris, Athanasios ;
Kabir, Abuzar ;
Furton, Kenneth G. ;
Samanidou, Victoria .
JOURNAL OF SEPARATION SCIENCE, 2019, 42 (07) :1440-1450