Evaluation of a 50-MV photon therapy beam from a racetrack microtron - Using MCNP4B Monte Carlo code

被引:0
作者
Gudowska, I [1 ]
Sorcini, B [1 ]
Svensson, R [1 ]
机构
[1] Karolinska Inst, Dept Med Radiat Phys, S-17176 Stockholm, Sweden
来源
ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS | 2001年
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
High energy photon therapy beam from the 50 MV racetrack microtron has been evaluated using the Monte Carlo code MCNP4B. The spatial and energy distribution of photons, radial and depth dose distributions in the phantom are calculated for the stationary and scanned photon beams from different targets. The calculated dose distributions are compared to the experimental data using a silicon diode detector. Measured and calculated depth-dose distributions are in fairly good agreement, within 2-3% for the positions in the range 2-30 cm in the phantom, whereas the larger discrepancies up to 10% are observed in the dose build-up region. For the stationary beams the differences in the calculated and measured radial dose distributions are about 2-10%.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 17 条
[1]   ELECTRON AND PHOTON BEAMS FROM A 50 MEV RACETRACK MICROTRON [J].
BRAHME, A ;
KRAEPELIEN, T ;
SVENSSON, H .
ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (04) :305-319
[2]  
Briesmeister J. F., 1997, LA12625M LANL
[3]   A virtual source model for Monte Carlo modeling of arbitrary intensity distributions [J].
Chetty, I ;
DeMarco, JJ ;
Solberg, TD .
MEDICAL PHYSICS, 2000, 27 (01) :166-172
[4]   VERIFICATION OF THE MONTE-CARLO CODE MCNP FOR THICK TARGET BREMSSTRAHLUNG CALCULATIONS [J].
DEMARCO, JJ ;
SOLBERG, TD ;
WALLACE, RE ;
SMATHERS, JB .
MEDICAL PHYSICS, 1995, 22 (01) :11-16
[5]   CT-based Monte Carlo simulation tool for dosimetry planning and analysis [J].
DeMarco, JJ ;
Solberg, TD ;
Smathers, JB .
MEDICAL PHYSICS, 1998, 25 (01) :1-11
[6]  
GIERGA DP, 1999, LA13440 LANL
[7]  
HUGHES HG, TREATING ELECT TRANS
[8]   An MCNP-based model of a linear accelerator x-ray beam [J].
Lewis, RD ;
Ryde, SJS ;
Hancock, DA ;
Evans, CJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (05) :1219-1230
[9]   Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses [J].
Love, PA ;
Lewis, DG ;
Al-Affan, IAM ;
Smith, CW .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (05) :1351-1357
[10]  
Nelson W., 1985, SLAC265