Effect of gamma-irradiation on the colorimetric properties of epoxy-resin films: Potential use in dosimetric application

被引:15
作者
Hosni, F. [1 ,2 ]
Farah, K. [1 ,3 ]
Kaouach, H. [4 ]
Louati, A. [2 ]
Chtourou, R. [4 ]
Hamzaoui, A. H. [5 ]
机构
[1] Ctr Natl Sci & Technol Nucl, Unite Rech Maitrise Tech Nucl Caractere Pacifique, Sidi Thabet 2020, Tunisia
[2] Acad Mil Fondouk Jedid, Nabeul 8012, Tunisia
[3] Univ Sousse, Inst Super Transport & Logist, Sousse, Tunisia
[4] Inst Natl Rech Sci & Tech, Hammam Lif 2050, Tunisia
[5] Ctr Natl Rech Sci Mat, Lab Valorisat Mat Utiles, Hammam Lif 2050, Tunisia
关键词
Epoxy resin; Gamma irradiation; Colorimetry; Radiation indicator; Radiation dosimeter; ELECTRICAL-PROPERTIES; RADIATION RESPONSE;
D O I
10.1016/j.nimb.2013.06.003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The present paper reports the results of the colorimetric study of gamma-irradiated epoxy-resin films. Epoxy-resin samples were irradiated by gamma-rays with doses varying from 1 to 50 kGy. Color changes of epoxy-resin were observed and studied by the measurements of the variation of the L*, a*, b* as function of dose and post-irradiation time. Where L* is a measure of the magnitude of brightness from black to white, parameter a*. describe the relative amounts of red and green, and parameter b* describes the relative amounts of yellow and blue color. Color changes (Delta E) were also calculated. They indicated a marked dependence of the absorbed doses showing the optical activation of the color centers. It was found that color changes (Delta E) due to absorbed dose increase from 6 to 50. Color change showed a low variability which did not exceed 3% for the measurements carried out between 1 and 72 h. The obtained results revealed that epoxy-resin films can be used as a new routine dosimeter or irradiation indicator in dose range 1-50 kGy. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 19 条
[1]   DISCOLORATION AND SUBSEQUENT RECOVERY OF OPTICAL POLYMERS EXPOSED TO IONIZING-RADIATION [J].
CLOUGH, RL ;
MALONE, GM ;
GILLEN, KT ;
WALLACE, JS ;
SINCLAIR, MB .
POLYMER DEGRADATION AND STABILITY, 1995, 49 (02) :305-313
[2]   Color formation in irradiated polymers [J].
Clough, RL ;
Gillen, KT ;
Malone, GM ;
Wallace, JS .
RADIATION PHYSICS AND CHEMISTRY, 1996, 48 (05) :583-594
[3]   APPLICATION OF EPOXY-RESINS IN ELECTRICAL APPARATUS [J].
DAKIN, TW .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1974, EI 9 (04) :121-128
[4]   Investigation of the effect of some irradiation parameters on the response of various types of dosimeters to electron irradiation [J].
Farah, K ;
Kuntz, F ;
Kadri, O ;
Ghedira, L .
RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (1-2) :339-343
[5]   Characterization of a silicate glass as a high dose dosimeter [J].
Farah, K. ;
Mejri, A. ;
Hosni, F. ;
Ben Ouada, H. ;
Fuochi, P. G. ;
Lavalle, M. ;
Kovacs, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 614 (01) :137-144
[6]  
FOURACRE RA, 1991, RADIAT PHYS CHEM, V37, P581
[7]  
FOURACRE RA, 1991, RADIAT PHYS CHEM, V37, P589
[8]   Identification of photoluminescence features of an epoxy resin based on components features and curing effects [J].
Gallot-lavallée, O ;
Teyssedre, G ;
Laurent, C ;
Rowe, S .
POLYMER, 2005, 46 (08) :2722-2731
[9]   A study of the fractionation dose on the radiation response of Harwell Red-Perspex PMMA dosimeter [J].
Hosni, F. ;
Farah, K. ;
Mejri, A. ;
Khayat, A. ;
Chtourou, R. ;
Hamzaoui, A. H. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 290 :69-71
[10]  
ISO/ASTM, 2004, E1026 ISOASTM