Modification of electrodes using conductive porous layers to confer selectivity for the voltammetric detection of paracetamol in the presence of ascorbic acid, dopamine and uric acid

被引:72
作者
Kutluay, Aysegul [1 ]
Aslanoglu, Mehmet [1 ]
机构
[1] Univ Harran, Dept Chem, TR-63510 Sanliurfa, Turkey
关键词
Paracetamol; Carbon nanotubes; Porous layers; Modification; Selectivity; Thin layer; Ascorbic acid; Uric acid; Dopamine; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL DETERMINATION; SENSITIVE DETECTION; FLOW SYSTEM; ACETAMINOPHEN; SENSOR; NANOTUBES; COMPOSITE; BIOSENSORS; OXIDATION;
D O I
10.1016/j.snb.2013.05.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode (GCE) has been modified with multiwalled carbon nanotubes (MWCNTs) for the selective detection of paracetamol (PAR) in the presence of ascorbic acid (AA), dopamine (DA) and uric acid (UA). The oxidation of PAR shows a quasi-reversible response on a naked GCE at which an appreciable overpotential is required to drive the two electron oxidation. However, the peak-to-peak separation is seen to reduce and the electrochemical signal appears more reversible as the GCE is modified with an increasingly thick layer of MWCNTs. The results indicate that both anodic and cathodic peaks occur at lower overpotential with increasing layer thickness on the electrode surface, and that the overall peak-to-peak separation decreases as a result. The data are consistent with a transition from planar diffusion to a thin layer character as the potential required for the oxidation of PAR shifts to lower potentials. The experimental results show that the use of conducting porous layers on the surface of electrodes can be utilised to modify the mass transport regime from planar diffusion to a thin layer character that this alteration can also favourably facilitate the electrochemical discrimination between species which oxidise or reduce at similar potentials under planar diffusion conditions. The modified electrode was used for the determination of PAR using square wave voltammetry in 0.1 M phosphate buffer solution (PBS) at pH 7. The results showed that the peak currents were proportional to the concentrations of PAR with a linear dynamic range of 2.0 x 10(-10) M to 1.5 x 10(-5) M and a detection limit of 9.0 x 10(-11) M was obtained. The method has successfully been applied for the determination of PAR in pharmaceuticals. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:398 / 404
页数:7
相关论文
共 58 条
[1]   FT-IR and Raman spectroscopic methods for identification and quantitation of orthorhombic and monoclinic paracetamol in powder mixes [J].
Al-Zoubi, N ;
Koundourellis, JE ;
Malamataris, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (03) :459-467
[2]   Simultaneous electrochemical determination of dopamine and acetaminophen using multiwall carbon nanotubes modified glassy carbon electrode [J].
Alothman, Zeid Abdullah ;
Bukhari, Nausheen ;
Wabaidur, Saikh Mohammad ;
Haider, Sajjad .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :314-320
[3]   A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite as a New Sensor for Simultaneous Determination of Acetaminophen and Mefenamic Acid in Pharmaceutical Preparations and Biological Samples [J].
Babaei, Ali ;
Afrasiabi, Mohammad ;
Babazadeh, Mitra .
ELECTROANALYSIS, 2010, 22 (15) :1743-1749
[4]   A high performance electrochemical sensor for acetaminophen based on single-walled carbon nanotube-graphene nanosheet hybrid films [J].
Chen, Xu ;
Zhu, June ;
Xi, Qian ;
Yang, Wensheng .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :648-654
[5]   Peptide modified electrodes as electrochemical metal ion sensors [J].
Chow, Edith ;
Gooding, J. Justin .
ELECTROANALYSIS, 2006, 18 (15) :1437-1448
[6]   Effects of EDTA on signal stability during electrochemical detection of acetaminophen [J].
de Carvalho, RM ;
Freire, RS ;
Rath, S ;
Kubota, LT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (05) :871-878
[7]   Chemiluminescence detection of paracetamol by a luminol-permanganate based reaction [J].
Easwaramoorthy, D ;
Yu, YC ;
Huang, HJ .
ANALYTICA CHIMICA ACTA, 2001, 439 (01) :95-100
[8]   Simultaneous determination of N-acetylcysteine and acetaminophen by voltammetric method using N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide modified multiwall carbon nanotubes paste electrode [J].
Ensafi, Ali A. ;
Karimi-Maleh, Hassan ;
Mallakpour, S. ;
Hatami, M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02) :464-472
[9]   A differential pulse voltammetric method for simultaneous determination of ascorbic acid, dopamine, and uric acid using poly (3-(5-chloro-2-hydroxyphenylazo)-4,5-dihydroxynaphthalene-2,7-disulfonic acid) film modified glassy carbon electrode [J].
Ensafi, Ali A. ;
Taei, M. ;
Khayamian, T. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 633 (01) :212-220
[10]   Electrochemical behavior and voltammetric determination of paracetamol on Nafion/TiO2-graphene modified glassy carbon electrode [J].
Fan, Yang ;
Liu, Jin-Hang ;
Lu, Hai-Ting ;
Zhang, Qin .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 85 (02) :289-292