Measurement of transmission of vibration through the human spine using skin-mounted inertial sensors

被引:14
作者
Ramirez, Dafne Z. Morgado [1 ]
Strike, Siobhan [1 ]
Lee, Raymond Y. W. [1 ]
机构
[1] Univ Roehampton, Roehampton, England
基金
英国工程与自然科学研究理事会;
关键词
Spine; Physical activity; Inertial sensor; Skin; Vibration transmission; WHOLE-BODY VIBRATION; WALKING; SIMULATION; INVIVO; SHOCK;
D O I
10.1016/j.medengphy.2012.12.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to examine the feasibility of measuring the transmission of vibration using skin mounted inertial sensors and to assess the dynamic properties of the human spine during activities of daily living. Two inertial sensors were attached to skin overlying the first thoracic vertebra (T1) and another one over the first sacral vertebra (S1) with double sided adhesive tape. Subjects walked along a straight line, and up and down stairs at a self selected, comfortable speed. Transmissibility of vertical vibration was calculated as the ratio of the power spectral density of the acceleration signal at T1 over that at S1, over the frequency range of 0.5-12 Hz. Cross correlation and coherence of the acceleration signals between the two T1 sensors were performed to evaluate the similarity of the data after correction. Cross correlation of signals between trials was also performed to examine the repeatability of the signals. Cross correlation coefficients were found to be very high (>0.9). Inter-trial consistency of the signals of all sensors was also high (>0.9). It is concluded that skin measurement of transmission of vertical vibration is feasible with the inertial sensors and correction method presented. Different physical activities seem to elicit different frequency characteristics of vibration. (C) 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:690 / 695
页数:6
相关论文
共 24 条
  • [1] Angeloni C., 1994, IEEE Transactions on Rehabilitation Engineering, V2, P40, DOI 10.1109/86.296343
  • [2] [Anonymous], WHO TECHNICAL REPORT
  • [3] LOW-FREQUENCY SELF-GENERATED VIBRATION DURING AMBULATION IN NORMAL MEN
    CAPPOZZO, A
    [J]. JOURNAL OF BIOMECHANICS, 1982, 15 (08) : 599 - 609
  • [4] AN INVITRO SIMULATION STUDY OF IMPULSIVE FORCE TRANSMISSION ALONG THE LOWER SKELETAL EXTREMITY
    CHU, ML
    YAZDANIARDAKANI, S
    GRADISAR, IA
    ASKEW, MJ
    [J]. JOURNAL OF BIOMECHANICS, 1986, 19 (12) : 979 - &
  • [5] IMPULSIVE FORCES DURING WALKING AND THEIR CLINICAL IMPLICATIONS
    COLLINS, JJ
    WHITTLE, MW
    [J]. CLINICAL BIOMECHANICS, 1989, 4 (03) : 179 - 187
  • [6] Age, gender and speed effects on spinal kinematics during walking
    Crosbie, J
    Vachalathiti, R
    Smith, R
    [J]. GAIT & POSTURE, 1997, 5 (01) : 13 - 20
  • [7] Changes in joint stability with muscle contraction measured from transmission of mechanical vibration
    Feltham, M. G.
    van Dieen, J. H.
    Coppieters, M. W.
    Hodges, P. W.
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (15) : 2850 - 2856
  • [8] Griffin MJ., 1990, Handbook of Human Vibration
  • [9] Helliwell PS, 1989, ARCH P I MECH ENG H, V203, p[203, 187, 187]
  • [10] Is vibration truly an injurious stimulus in the human spine?
    Hill, Taryn E.
    Desmoulin, Geoffrey T.
    Hunter, Christopher J.
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (16) : 2631 - 2635