An electrochemical aptasensor based on gold nanoparticles and graphene oxide doped poly(3,4-ethylenedioxythiophene) nanocomposite for detection of MUC1

被引:49
作者
Gupta, Pernika [1 ]
Bharti, Anu [1 ]
Kaur, Navpreet [1 ]
Singh, Suman [2 ]
Prabhakar, Nirmal [1 ]
机构
[1] Panjab Univ, Dept Biochem, Chandigarh 160014, India
[2] CSIR, CSIO, Chandigarh, India
关键词
Electrochemical; Aptasensor; Breast cancer; MUC1; Poly(3,4 ethylenedioxythiophene); Gold nanoparticles; Graphene oxide; BREAST-CANCER CELLS; TUMOR-MARKER; GLUCOSE BIOSENSOR; APTAMER BIOSENSOR; CARBON NANOTUBES; HYBRID MATERIAL; LABEL-FREE; ELECTRODE; DNA; CHITOSAN;
D O I
10.1016/j.jelechem.2018.02.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, we have developed an electrochemical aptasensor for detection of breast cancer biomarker protein, mucin1 (MUC1). Gold nanoparticles (AuNPs) and graphene oxide (GO) doped Poly(3,4-ethylenedioxythiophene) (PEDOT) nanocomposite films were deposited onto the surface of fluorine tin oxide (FPO) glass sheets by electropolymerization using chronoamperometry technique at a potential of 1.0 V for 180 s. MUC1 specific biotinylated aptamer was immobilized onto the AuNPs-GO-PEDOT nanocomposite film via biotin-avidin interaction strategy. The biotinylated aptamer immobilized electrodes were characterized using contact angle measurement studies, FT-IR and electrochemical techniques. Optimization parameters like aptamer concentration and response time were also studied. The developed aptaelectrode was used for the sensing of MUC1 with limit of detection (LOD) of about 1 fg/mL (0.031 fM). The stability and reusability of the aptaelectrode was observed to be 14 days and 8 times, respectively. The fabricated aptaelectrode was also applied for the determination of MUC1 in spiked human serum samples with 85-93% recovery.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 58 条
[1]   Effect of electropolymerization potential on the preparation of PEDOT/graphene oxide hybrid material for supercapacitor application [J].
Azman, Nur Hawa Nabilah ;
Lim, Hong Ngee ;
Sulaiman, Yusran .
ELECTROCHIMICA ACTA, 2016, 188 :785-792
[2]   A library of IR bands of nucleic acids in solution [J].
Banyay, M ;
Sarkar, M ;
Gräslund, A .
BIOPHYSICAL CHEMISTRY, 2003, 104 (02) :477-488
[3]   Biosensors: the new wave in cancer diagnosis [J].
Bohunicky, Brian ;
Mousa, Shaker A. .
NANOTECHNOLOGY SCIENCE AND APPLICATIONS, 2011, 4 :1-10
[4]   Label-free and high-sensitive detection of human breast cancer cells by aptamer-based leaky surface acoustic wave biosensor array [J].
Chang, Kai ;
Pi, Yan ;
Lu, Weiping ;
Wang, Feng ;
Pan, Feng ;
Li, Fake ;
Jia, Shuangrong ;
Shi, Jianfeng ;
Deng, Shaoli ;
Chen, Ming .
BIOSENSORS & BIOELECTRONICS, 2014, 60 :318-324
[5]   Discrimination of Breast Cancer by Measuring Prostate-Specific Antigen Levels in Women's Serum [J].
Chang, Ying-Feng ;
Hung, Shuo-Hui ;
Lee, Yi-Jang ;
Chen, Ran-Chou ;
Su, Li-Chen ;
Lai, Chao-Sung ;
Chou, Chien .
ANALYTICAL CHEMISTRY, 2011, 83 (13) :5324-5328
[6]   Aptamer-Based Detection of Epithelial Tumor Marker Mucin 1 with Quantum Dot-Based Fluorescence Readout [J].
Cheng, Alan K. H. ;
Su, Huaipeng ;
Wang, Andrew ;
Yu, Hua-Zhong .
ANALYTICAL CHEMISTRY, 2009, 81 (15) :6130-6139
[7]   Electrochemical detection of HER2 using single stranded DNA aptamer modified gold nanoparticles electrode [J].
Chun, Limin ;
Kim, Sung-Eun ;
Cho, Misuk ;
Choe, Woo-seok ;
Nam, Jaedo ;
Lee, Daniel W. ;
Lee, Youngkwan .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 :446-450
[8]   The chemistry of graphene oxide [J].
Dreyer, Daniel R. ;
Park, Sungjin ;
Bielawski, Christopher W. ;
Ruoff, Rodney S. .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (01) :228-240
[9]   One-step electrochemically deposited interface of chitosan-gold nanoparticles for acetylcholinesterase biosensor design [J].
Du, Dan ;
Ding, Jiawang ;
Cai, Jie ;
Zhang, Aidong .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 605 (01) :53-60
[10]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822