Nasotracheal intubation with three indirect laryngoscopes assisted by standard or modified Magill forceps

被引:22
作者
Staar, S. [1 ]
Biesler, I. [1 ]
Mueller, D. [1 ]
Pfoertner, R. [2 ]
Mohr, C. [2 ]
Groeben, H. [1 ]
机构
[1] Kliniken Essen Mitte, Dept Anaesthesia Crit Care Med & Pain Therapy, Essen, Germany
[2] Kliniken Essen Mitte, Dept Oral & Craniomaxillofacial Surg Kliniken Ess, Essen, Germany
关键词
DIFFICULT TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; AIRWAY MANAGEMENT; TUBE PLACEMENT; AIRTRAQ(R); GLIDESCOPE(R); METAANALYSIS; MANNEQUIN; BOUGIE;
D O I
10.1111/anae.12175
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We assessed the effect of modifying standard Magill forceps on the laryngeal introduction of an Eschmann stylet during nasotracheal intubations with three indirect laryngoscopes (Airtraq, C-MAC (R) or GlideScope (R)) in patients with predicted difficult intubation. We allocated 50 participants to each laryngoscope. The stylet was advanced by one forceps followed by the other (standard or modified), with each sequence allocated to 25/50 for each laryngoscope. There were no differences in rates of failed tracheal intubation with the allocated laryngoscopes: 6/50, 5/50 and 5/50, respectively. An Eschmann stylet was advanced into the trachea less often with the standard forceps (65% vs 93%, p<0.0001). Mean (SD) time for stylet advancement was longer with the standard forceps, 38 (30) vs 19 (19) s, p<0.0001. In conclusion, the modified Magill forceps facilitated nasotracheal intubation, independent of the type of indirect laryngoscope.
引用
收藏
页码:467 / 471
页数:5
相关论文
共 20 条
[1]   Videolaryngoscopes Do They Truly Have Roles in Difficult Airways? [J].
Asai, Takashi .
ANESTHESIOLOGY, 2012, 116 (03) :515-517
[2]  
Ayuso MA, 2003, CAN J ANAESTH, V50, P81, DOI 10.1007/BF03020193
[3]   Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway [J].
Aziz, Michael F. ;
Dillman, Dawn ;
Fu, Rongwei ;
Brambrink, Ansgar M. .
ANESTHESIOLOGY, 2012, 116 (03) :629-636
[4]   Comparison of the Magill forceps and the Boedeker (curved) intubation forceps for removal of a foreign body in a Manikin [J].
Boedeker, Ben H. ;
Bernhagen, Mary A. Barak ;
Miller, David J. ;
Doyle, D. John .
JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (01) :25-27
[5]  
Cooper RM, 2003, CAN J ANAESTH, V50, P611, DOI 10.1007/BF03018651
[6]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[7]  
Cossham PS, 1997, ANAESTHESIA, V52, P184
[8]   SUCCESSFUL DIFFICULT INTUBATION - TRACHEAL TUBE PLACEMENT OVER A GUM-ELASTIC BOUGIE [J].
DOGRA, S ;
FALCONER, R ;
LATTO, IP .
ANAESTHESIA, 1990, 45 (09) :774-776
[9]   Nasotracheal intubation for head and neck surgery [J].
Hall, CEJ ;
Shutt, LE .
ANAESTHESIA, 2003, 58 (03) :249-256
[10]   Expected difficult tracheal intubation: a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients [J].
Jungbauer, A. ;
Schumann, M. ;
Brunkhorst, V. ;
Boergers, A. ;
Groeben, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (04) :546-550