The influence of stem taper re-use upon the failure load of ceramic heads

被引:14
作者
Guehrs, Julian [1 ]
Krull, Annika [1 ]
Witt, Florian [1 ]
Morlock, Michael M. [1 ]
机构
[1] TUHH Hamburg Univ Technol, D-21073 Hamburg, Germany
关键词
Total hip replacement; Stem taper re-use; Ceramic bearings; Fracture load; Head-taper connection; TOTAL HIP-ARTHROPLASTY; FEMORAL HEADS; FRACTURE; REVISION; METAL; BEARINGS; CORROSION; STRENGTH; JUNCTION;
D O I
10.1016/j.medengphy.2015.03.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ceramic components are frequently used in total hip replacement due to their good tribological properties. In revision of broken ceramic heads clinical uncertainties arise, whether the taper of the stem can be reused with a new ceramic head, especially if the stem is well fixed. Ceramic is a brittle material. Even small damage on the male stem taper can lead to stress concentrations causing premature failure of a new ceramic head. As a consequence, manufactures strictly prohibit stem taper re-use for ceramic heads. The aim of this study was to determine the fracture strength of ceramic heads assembled to re-used male stem tapers, which were subjected to prior head fracture. Five 12/14 Ti6Al4V male tapers and 15 Al2O3 ceramic heads (BIOLOX forte (R); circle divide 28 mm, L) were used for three consecutive fracture tests. Before and after every fracture test, all components were inspected visually and the surface geometry was analyzed. Mean fracture force (52.5 kN) did not decrease with the number of taper re-uses (p >= 0.77) but the range increased significantly from initially 4.1 kN to 31.8 kN for the first and 52.6 kN for the second re-use due to some components failing at very low loads. Visual inspection was not sufficient to predict the reduced failure loads. Ceramic heads should therefore not be put on used male tapers without metal adapter sleeves. 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:545 / 552
页数:8
相关论文
共 35 条
  • [1] Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study
    Allain, J
    Roudot-Thoraval, F
    Delecrin, J
    Anract, P
    Migaud, H
    Goutallier, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) : 825 - 830
  • [2] The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections
    Baxmann, M.
    Jauch, S. Y.
    Schilling, C.
    Bloemer, W.
    Grupp, T. M.
    Morlock, M. M.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2013, 35 (05) : 676 - 683
  • [3] Hip joint contact forces during stumbling
    Bergmann, G
    Graichen, F
    Rohlmann, A
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2004, 389 (01) : 53 - 59
  • [4] Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings
    Bishop, Nicholas
    Witt, Florian
    Pourzal, Robin
    Fischer, Alfons
    Ruetschi, Marcel
    Michel, Markus
    Morlock, Michael
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (07) : 1116 - 1122
  • [5] Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck
    Cooper, H. John
    Urban, Robert M.
    Wixson, Richard L.
    Meneghini, R. Michael
    Jacobs, Joshua J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (10) : 865 - 872
  • [6] Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years
    D'Antonio, James A.
    Capello, William N.
    Naughton, Marybeth
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) : 373 - 381
  • [7] Cemented revision of failed uncemented femoral components of total hip arthroplasty
    Davis, CM
    Berry, DJ
    Harmsen, WS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07) : 1264 - 1269
  • [8] Revision of the cemented femoral stem using a cement-in-cement technique A FIVE-TO 15-YEAR REVIEW
    Duncan, W. W.
    Hubble, M. J. W.
    Howell, J. R.
    Whitehouse, S. L.
    Timperley, A. J.
    Gie, G. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (05): : 577 - 582
  • [9] Ceramic Component Fracture: Trends and Recommendations with Modern Components based on improved Reporting Methods
    Garino, J. P.
    [J]. BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 157 - 168
  • [10] Fracture of ceramic heads in total hip replacement
    Habermann, B.
    Ewald, W.
    Rauschmann, M.
    Zichner, L.
    Kurth, A. A.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (07) : 464 - 470