摘要
Purpose: To develop a fast and accurate method for 3D T-2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. Methods: 3D high-resolution T-2-weighted images (0.9 x 0.9 x 3 mm(3)) were obtained with a multishot T-2-prepared balanced steady-state free precession (T-2-prep-bSSFP) acquisition sequence using a 3D variable density undersampled Cartesian trajectory. Each T-2-weighted image was reconstructed using total variation regularized sensitivity encoding. A flexible simulation framework based on extended phase graphs generated a dictionary of magnetization signals, which was customized to the proposed sequence. The dictionary was matched to the acquired T-2-weighted images to retrieve quantitative T-2 values, which were then compared to gold-standard spin echo acquisition values using monoexponential fitting. The proposed approach was validated in simulations and a T-1/T-2 phantom, and feasibility was tested in 8 healthy subjects. Results: The simulation analysis showed that the proposed T-2 mapping approach is robust to noise and typically observed T-1 variations. T-2 values obtained in the phantom with T(2)prep-bSSFP and the acquisition-specific, dictionary-based matching were highly correlated with the gold-standard spin echo method (r = 0.99). Furthermore, no differences were observed with the accelerated acquisition compared to the fully sampled acquisition (r = 0.99). T-2 values obtained in prostate peripheral zone, central gland, and muscle in healthy subjects (age, 26 +/- 6 years) were 97 +/- 14, 76 +/- 7, and 36 +/- 3 ms, respectively. Conclusion: 3D quantitative T-2 mapping of the whole prostate can be achieved in 3 minutes.
引用
收藏
页码:1795 / 1805
页数:11
相关论文
共 50 条
  • [11] Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution
    Bustin, Aurelien
    Milotta, Giorgia
    Ismail, Tevfik F.
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 988 - 1002
  • [12] T2 mapping and T2*imaging in heart failure
    Lota, A. S.
    Gatehouse, P. D.
    Mohiaddin, R. H.
    HEART FAILURE REVIEWS, 2017, 22 (04) : 431 - 440
  • [13] Phase-based T2 mapping with gradient echo imaging
    Wang, Xiaoke
    Hernando, Diego
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 609 - 619
  • [14] Fast in vivo 23Na imaging and T2* mapping using accelerated 2D-FID UTE magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study
    Alhulail, Ahmad A.
    Xia, Pingyu
    Shen, Xin
    Nichols, Miranda
    Volety, Srijyotsna
    Farley, Nicholas
    Thomas, Micheal Albert
    Nagel, Armin M.
    Dydak, Ulrike
    Emir, Uzay E.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 1783 - 1794
  • [15] T2 and T2* mapping and weighted imaging in cardiac MRI
    Topriceanu, Constantin-Cristian
    Pierce, Iain
    Moon, James C.
    Captur, Gabriella
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 15 - 32
  • [16] Feasibility of accelerated T2 mapping for the preoperative assessment of endometrial carcinoma
    Zhang, Zanxia
    Liu, Jie
    Wang, Weijian
    Zhang, Yong
    Qu, Feifei
    Hilbert, Tom
    Kober, Tobias
    Cheng, Jingliang
    Li, Shujian
    Zhu, Jinxia
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [17] Evaluating the accuracy of multicomponent T2 parameters for luminal water imaging of the prostate with acceleration using inner-volume 3D GRASE
    Chan, Rachel W.
    Lau, Angus Z.
    Detzler, Garry
    Thayalasuthan, Vivekanandan
    Nam, Robert K.
    Haider, Masoom A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 466 - 476
  • [18] Accelerated T2 mapping combining parallel MRI and model-based reconstruction: GRAPPATINI
    Hilbert, Tom
    Sumpf, Tilman J.
    Weiland, Elisabeth
    Frahm, Jens
    Thiran, Jean-Philippe
    Meuli, Reto
    Kober, Tobias
    Krueger, Gunnar
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (02) : 359 - 368
  • [19] Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping
    Sprinkart, Alois M.
    Luetkens, Julian A.
    Traeber, Frank
    Doerner, Jonas
    Gieseke, Juergen
    Schnackenburg, Bernhard
    Schmitz, Georg
    Thomas, Daniel
    Homsi, Rami
    Block, Wolfgang
    Schild, Hans
    Naehle, Claas P.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [20] MR imaging assessment of myocardial edema with T2 mapping
    Montant, P.
    Sigovan, M.
    Revel, D.
    Douek, P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (09) : 885 - 890