Model for excess noise in voltage-biased superconducting bolometers

被引:19
作者
Gildemeister, JM [1 ]
Lee, AT [1 ]
Richards, PL [1 ]
机构
[1] Univ Calif Berkeley, Dept Phys, Berkeley, CA 94720 USA
关键词
D O I
10.1364/AO.40.006229
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We are developing superconducting transition-edge bolometers for far-infrared and millimeter wavelengths. The bolometers described. here are suspended by thin legs of silicon nitride for thermal isolation. At frequencies between 200 mHz and 10-50 Hz these devices show white noise at their thermal fluctuation limit (NEP approximate to 10(-17) W/root Hz). At higher frequencies a broad peak appears in the noise spectrum, which we attribute to a combination of thermal fluctuations in complex thermal circuits and electrothermal feedback. Detailed noise calculations fit the noise measured in three different devices that were specifically designed to test the model. We discuss how changes in bolometer materials can shift the noise peak above the frequency range of interest for most applications.
引用
收藏
页码:6229 / 6235
页数:7
相关论文
共 13 条
[1]   Properties of the phonon gas in ultrathin membranes at low temperature [J].
Anghel, DV ;
Pekola, JP ;
Leivo, MM ;
Suoknuuti, JK ;
Manninen, M .
PHYSICAL REVIEW LETTERS, 1998, 81 (14) :2958-2961
[2]  
BOCK JJ, 1999, COMMUNICATION
[3]   Performance of multiplexed SQUID readout for Cryogenic Sensor Arrays [J].
Chervenak, JA ;
Grossman, EN ;
Irwin, KD ;
Martinis, JM ;
Reintsema, CD ;
Allen, CA ;
Bergman, DI ;
Moseley, SH ;
Shafer, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :107-110
[4]   Monolithic arrays of absorber-coupled voltage-biased superconducting bolometers [J].
Gildemeister, JM ;
Lee, AT ;
Richards, PL .
APPLIED PHYSICS LETTERS, 2000, 77 (24) :4040-4042
[5]   A fully lithographed voltage-biased superconducting spiderweb bolometer [J].
Gildemeister, JM ;
Lee, AT ;
Richards, PL .
APPLIED PHYSICS LETTERS, 1999, 74 (06) :868-870
[6]   AN APPLICATION OF ELECTROTHERMAL FEEDBACK FOR HIGH-RESOLUTION CRYOGENIC PARTICLE-DETECTION [J].
IRWIN, KD .
APPLIED PHYSICS LETTERS, 1995, 66 (15) :1998-2000
[7]  
IRWIN KD, 1999, COMMUNICATION
[8]   A superconducting bolometer with strong electrothermal feedback [J].
Lee, AT ;
Richards, PL ;
Nam, SW ;
Cabrera, B ;
Irwin, KD .
APPLIED PHYSICS LETTERS, 1996, 69 (12) :1801-1803
[9]   Voltage-biased superconducting transition-edge bolometer with strong electrothermal feedback operated at 370 mK [J].
Lee, SF ;
Gildemeister, JM ;
Holmes, W ;
Lee, AT ;
Richards, PL .
APPLIED OPTICS, 1998, 37 (16) :3391-3397
[10]   BOLOMETER NOISE - NON-EQUILIBRIUM THEORY [J].
MATHER, JC .
APPLIED OPTICS, 1982, 21 (06) :1125-1129