EDUCATION ON PATIENT-VENTILATOR SYNCHRONY, CLINICIANS' KNOWLEDGE LEVEL, AND DURATION OF MECHANICAL VENTILATION

被引:9
作者
Lynch-Smith, Donna [1 ]
Thompson, Carol Lynn [3 ]
Pickering, Rexann G. [4 ]
Wan, Jim Y. [2 ]
机构
[1] Univ Tennessee, Ctr Hlth Sci, AG ACNP Program, Memphis, TN 38163 USA
[2] Univ Tennessee, Ctr Hlth Sci, Coll Biostat & Epidemiol, Memphis, TN 38163 USA
[3] Univ Kentucky, Coll Nursing, Lexington, KY 40506 USA
[4] Memphis Hosp, Methodist Healthcare, Human Protect, Memphis, TN USA
关键词
ASYNCHRONY; FLOW;
D O I
10.4037/ajcc2016623
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Improved recognition of patient-ventilator asynchrony may reduce duration of mechanical ventilation. Objective To evaluate the effects of education about patient-ventilator synchrony on clinicians' level of knowledge and patients' mean duration of mechanical ventilation. Methods A quasi-experimental 1-group pretest-posttest study was performed in a 16-bed intensive care unit. Analysis included 33 clinicians and 97 ventilator patients. The intervention consisted of PowerPoint lectures on patient-ventilator synchrony. Data included test scores before and after the education, scores on the Acute Physiology and Chronic Health Evaluation II, and mean duration of mechanical ventilation. Differences in scores before and after education, mean duration of mechanical ventilation, and mean health evaluation scores before and after education were determined by using t tests. Results Of the 33 clinicians, 17 were registered nurses and 16 were respiratory therapists. Posttest scores were 63% higher than pretest scores (P < .001). Before the lecture, 47 patients had a mean health evaluation score of 21 (SD, 7.8) and mean duration of mechanical ventilation of 5.4 (SD, 4.6) days. After the lecture, 50 patients had a mean health evaluation score of 24.6 (SD, 8.2) and mean duration of mechanical ventilation of 4.8 (SD, 4.3) days. Mean health evaluation score was marginally higher after the lecture (P = .054). Mean duration of mechanical ventilation did not differ (P = .54). Conclusions Clinicians' test scores increased significantly after patient-ventilator synchrony lectures. Mean duration of mechanical ventilation decreased by 0.6 days and health evaluation scores were marginally higher after the lectures.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 40 条
  • [21] Observational study of patient-ventilator asynchrony and relationship to sedation level
    de Wit, Marjolein
    Pedram, Sammy
    Best, Al M.
    Epstein, Scott K.
    JOURNAL OF CRITICAL CARE, 2009, 24 (01) : 74 - 80
  • [22] On the Need for Standard Definitions and Education to Optimize Patient-Ventilator Interactions
    Mireles-Cabodevila, Eduardo
    Dugar, Siddharth
    RESPIRATORY CARE, 2017, 62 (02) : 248 - 249
  • [23] Patient-ventilator synchrony under non-invasive ventilation is improved by an automated real time waveform analysis algorithm: a bench study
    Renaud, Yann
    Auroi, Jocelyne
    Cabrio, Davy
    Lupieri, Ermes
    Chiche, Jean-Daniel
    Piquilloud, Lise
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2025, 13 (01):
  • [24] A New Tool to Assess Patient-Ventilator Synchrony in Preterm Infants Receiving Non-Invasive Ventilation: A Randomized Crossover Pilot Study
    Cresi, Francesco
    Maggiora, Elena
    Rubino, Carlotta
    Ferroglio, Mattia
    Ruzzante, Elena
    Piga, Enrico
    Giraudo, Isaac
    Limone, Marco
    Terrin, Gianluca
    Coscia, Alessandra
    NEONATOLOGY, 2025,
  • [25] Patient-ventilator interaction with conventional and automated management of pressure support during difficult weaning from mechanical ventilation
    Grieco, Domenico Luca
    Bitondo, Maria Maddalena
    Aguirre-Bermeo, Hernan
    Italiano, Stefano
    Idone, Francesco Antonio
    Moccaldo, Antonia
    Santantonio, Maria Teresa
    Eleuteri, Davide
    Antonelli, Massimo
    Mancebo, Jordi
    Maggiore, Salvatore Maurizio
    JOURNAL OF CRITICAL CARE, 2018, 48 : 203 - 210
  • [26] Patient-ventilator interaction during pressure support ventilation and neurally adjusted ventilatory assist
    Spahija, Jadranka
    de Marchie, Michel
    Albert, Martin
    Bellemare, Patrick
    Delisle, Stephane
    Beck, Jennifer
    Sinderby, Christer
    CRITICAL CARE MEDICINE, 2010, 38 (02) : 518 - 526
  • [27] Patient-ventilator asynchrony during non-invasive ventilation for acute respiratory failure: a multicenter study
    Vignaux, Laurence
    Vargas, Frederic
    Roeseler, Jean
    Tassaux, Didier
    Thille, Arnaud W.
    Kossowsky, Michel P.
    Brochard, Laurent
    Jolliet, Philippe
    INTENSIVE CARE MEDICINE, 2009, 35 (05) : 840 - 846
  • [28] Neurally adjusted ventilatory assist improves patient-ventilator interaction during postextubation prophylactic noninvasive ventilation
    Schmidt, Matthieu
    Dres, Martin
    Raux, Mathieu
    Deslandes-Boutmy, Emmanuelle
    Kindler, Felix
    Mayaux, Julien
    Similowski, Thomas
    Demoule, Alexandre
    CRITICAL CARE MEDICINE, 2012, 40 (06) : 1738 - 1744
  • [29] Patient-Ventilator Synchronization During Non-invasive Ventilation: A Pilot Study of an Automated Analysis System
    Letellier, Christophe
    Lujan, Manel
    Arnal, Jean-Michel
    Carlucci, Annalisa
    Chatwin, Michelle
    Ergan, Begum
    Kampelmacher, Mike
    Storre, Jan Hendrik
    Hart, Nicholas
    Gonzalez-Bermejo, Jesus
    Nava, Stefano
    FRONTIERS IN MEDICAL TECHNOLOGY, 2021, 3
  • [30] Neurally adjusted ventilatory assist (NAVA) versus pressure support ventilation: patient-ventilator interaction during invasive ventilation delivered by tracheostomy
    Lamouret, Olivier
    Crognier, Laure
    Bounes, Fanny Vardon
    Conil, Jean-Marie
    Dilasser, Caroline
    Raimondi, Thibaut
    Ruiz, Stephanie
    Rouget, Antoine
    Delmas, Clement
    Seguin, Thierry
    Minville, Vincent
    Georges, Bernard
    CRITICAL CARE, 2019, 23 (1):