Reproducibility for linear and nonlinear micro-finite element simulations with density derived material properties of the human radius

被引:8
作者
Christen, David [1 ]
Zwahlen, Alexander [1 ]
Mueller, Ralph [1 ]
机构
[1] ETH, Inst Biomech, CH-8093 Zurich, Switzerland
关键词
Nonlinear finite element simulation; High resolution peripheral quantitative computed tomography (HRpQCT); Human radius; Bone strength; Material properties; Reproducibility; QUANTITATIVE COMPUTED-TOMOGRAPHY; HUMAN TRABECULAR BONE; IN-VIVO ASSESSMENT; MECHANICAL-PROPERTIES; DISTAL RADIUS; ANATOMIC SITE; RESOLUTION; FAILURE; MODELS; TISSUE;
D O I
10.1016/j.jmbbm.2013.10.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Finite element (FE) simulations based on high-resolution peripheral quantitative computed-tomography (HRpQCT) measurements provide an elegant and direct way to estimate bone strength. Parallel solvers for nonlinear FE simulations allow the assessment not only of the initial linear elastic behavior of the bone but also materially and geometrically nonlinear effects. The reproducibility of HRpQCT measurements, as well as their analysis of microarchitecture using linear-elastic FE simulations with a honiogeneous elastic modulus has been investigated before. However, it is not clear to which extent density-derived and nonlinear FE simulations are reproducible. In this study, we introduced new mechanical indices derived from nonlinear FE simulations that describe the onset of yielding and the behavior at maximal load. Using 14 embalmed forearms that were imaged three times, we found that in general the in vitro reproducibility of the nonlinear FE simulations is as good as the reproducibility of linear FE. For the nonlinear simulations precision errors (PEs) ranged between 0.4 and 3.2% and intraclass correlation coefficients were above 0.9. In conclusion, nonlinear FE simulations with density derived material properties contain important additional information that is independent from the results of the linear simulations. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:500 / 507
页数:8
相关论文
共 34 条
[11]   Multiscale modelling and nonlinear finite element analysis as clinical tools for the assessment of fracture risk [J].
Christen, David ;
Webster, Duncan James ;
Mueller, Ralph .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2010, 368 (1920) :2653-2668
[12]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[13]   Mathematical relationships between bone density and mechanical properties: A literature review [J].
Helgason, Benedikt ;
Perilli, Egon ;
Schileo, Enrico ;
Taddei, Fulvia ;
Brynjolfsson, Sigurour ;
Viceconti, Marco .
CLINICAL BIOMECHANICS, 2008, 23 (02) :135-146
[14]   Introduction and evaluation of a gray-value voxel conversion technique [J].
Homminga, J ;
Huiskes, R ;
Van Rietbergen, B ;
Rüegsegger, P ;
Weinans, H .
JOURNAL OF BIOMECHANICS, 2001, 34 (04) :513-517
[15]   Sensitivity of tissue differentiation and bone healing predictions to tissue properties [J].
Isaksson, Hanna ;
van Donkelaar, Corrinus C. ;
Ito, Keita .
JOURNAL OF BIOMECHANICS, 2009, 42 (05) :555-564
[16]   Effects of sex and age on bone microstructure at the ultradistal radius: A population-based noninvasive in vivo assessment [J].
Khosla, S ;
Riggs, BL ;
Atkinson, EJ ;
Oberg, AL ;
McDaniel, LJ ;
Holets, M ;
Peterson, JM ;
Melton, LJ .
JOURNAL OF BONE AND MINERAL RESEARCH, 2006, 21 (01) :124-131
[17]  
Kirmani S, 2009, J BONE MINER RES, V24, P1033, DOI [10.1359/JBMR.081255, 10.1359/jbmr.081255]
[18]   Comparison of structure extraction methods for in vivo trabecular bone measurements [J].
Laib, A ;
Rüegsegger, P .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1999, 23 (02) :69-74
[19]   Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality [J].
MacNeil, Joshua A. ;
Boyd, Steven K. .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (06) :792-799
[20]   Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality [J].
MacNeil, Joshua A. ;
Boyd, Steven K. .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) :1096-1105