Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settings

被引:115
作者
Gentner, Reinhard [1 ,2 ]
Classen, Joseph [1 ]
机构
[1] Univ Wurzburg, Dept Neurol, Human Cort Physiol & Motor Control Lab, D-97080 Wurzburg, Germany
[2] Tech Univ Munich, Inst Measurement Syst & Sensor Technol, D-80333 Munich, Germany
关键词
Sensor glove; Resistive bend sensors; Finger movement kinematics; Transcranial magnetic stimulation; INSTRUMENTED GLOVE; HAND SYNERGIES; MOTOR CORTEX; DAMAGE;
D O I
10.1016/j.jneumeth.2008.11.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sensor gloves for measurements of finger movements are a promising tool for objective assessments of kinematic parameters and new rehabilitation strategies. Here, a novel low-cost sensor glove equipped with resistive bend sensors is described and evaluated. Resistive bend sensors were modified in order to optimize measurement accuracy (quantified as the stability of sensor signal after a fast and constant bending) and to increase sensor linearity, reducing calibration time from several minutes to only similar to 10 s. Reliability analysis of the sensor glove in five subjects showed an intraclass correlation coefficient (ICC) of 0.93 +/- 0.05, a mean standard deviation of 1.59 degrees and an overall error of 4.96 degrees, comparable to previously evaluated sensor gloves. User acceptance and applicability, assessed by a user feedback questionnaire, was high. Thus, with minor modifications, resistive bend sensors are suitable for accurate assessments of human finger movements. The low material costs (<US$ 500) and easy manufacturing make this solution interesting for widespread use in research, clinical and rehabilitative settings. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 23 条
[1]  
Adamovich SV, 2004, P ANN INT IEEE EMBS, V26, P4936
[2]  
[Anonymous], 1995, ACM T COMPUT-HUM INT, DOI DOI 10.1145/212430.212431
[3]  
Beers MarkH., 1999, MERCK MANUAL DIAGNOS, V17th
[4]  
Boesnach I, 2004, CONF CYBERN INTELL S, P976
[5]   Rapid plasticity of human cortical movement representation induced by practice [J].
Classen, J ;
Liepert, J ;
Wise, SP ;
Hallett, M ;
Cohen, LG .
JOURNAL OF NEUROPHYSIOLOGY, 1998, 79 (02) :1117-1123
[6]  
Dipietro L, 2003, J REHABIL RES DEV, V40, P179
[7]   Modular organization of finger movements by the human central nervous system [J].
Gentner, Reinhard ;
Classen, Joseph .
NEURON, 2006, 52 (04) :731-742
[8]   Virtual environments for motor rehabilitation: Review [J].
Holden, MK .
CYBERPSYCHOLOGY & BEHAVIOR, 2005, 8 (03) :187-211
[9]  
HOMMEL G, 1994, P WWDU 94 4 INT SCI
[10]   Biological constraints simplify the recognition of hand shapes [J].
Jerde, TE ;
Soechting, JF ;
Flanders, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (02) :265-269