Miniaturized and automated sample pretreatment for determination of PCBs in environmental aqueous samples using an on-line microporous membrane liquid-liquid extraction-gas chromatography system

被引:42
作者
Barri, T
Bergström, S
Norberg, J
Jönsson, JA
机构
[1] Lund Univ, Dept Analyt Chem, SE-22100 Lund, Sweden
[2] Biotage AB, SE-75318 Uppsala, Sweden
关键词
D O I
10.1021/ac035089g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, fast, and automated sample pretreatment technique for determination of lipophilic organic compounds in aqueous samples has been developed and applied to the determination of polychlorinated biphenyls (PCBs) in environmental river water. It is based on miniaturized microporous membrane liquid-liquid extraction coupled on-line to gas chromatography (GC) with electron capture detection. The heart of the system that simultaneously connects the sample pretreatment step to the final GC analysis has been named the extracting syringe (ESy). The ESy carries a miniaturized membrane extraction card attached to an electrically and mechanically designed installment and is mounted directly over a GC injector for fully automated injection of the extract. A method was developed to extract 10 PCB congeners from 1-mL water samples (after addition of 40% acetonitrile) with an extraction time of 10 min. The optimized methodology showed good linearity (in the dynamic concentration range of 5 ng L-1-1 mug L-1), enrichment factors of 33-40 times, repeatable extractions (RSD 2-5%, n = 4), and low detection limits (2-3 ng L-1). Acetonitrile had to be added to the samples in order to overcome the influence of PCB adsorption on the repeatability of extraction and enrichment and to minimize the overall memory effect (OME). OME and carryover depended not only on the concentration of the organic solvent added to the sample and that used in the washing procedure but also on whether the extracting card was changed or not. When an optimized washing procedure was applied, the OME was similar to0.2% at high concentrations (i.e., 1 mug L-1). When each extraction took place in a new extraction card, no OME was detected. Additionally, no significant adsorption onto glass surfaces or a matrix effect on extraction was noticed. The main features of this methodology are good extraction repeatability, low detection limits at short extraction time, and the unsurpassed characteristic of no detectable OME in the entire system when each sample is processed in a new card. The total consumption of organic (nonchlorinated) solvents is less than 5 mL per sample.
引用
收藏
页码:1928 / 1934
页数:7
相关论文
共 42 条
  • [1] ANALYZING PCBS
    ALFORDSTEVENS, AL
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (12) : 1194 - 1199
  • [2] [Anonymous], OFFICIAL J EUR COM L
  • [3] Monitoring of priority pesticides and other organic pollutants in river water from Portugal by gas chromatography-mass spectrometry and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry
    Azevedo, DD
    Lacorte, S
    Vinhas, T
    Viana, P
    Barceló, D
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) : 13 - 26
  • [4] Sorptive sample preparation - a review
    Baltussen, E
    Cramers, CA
    Sandra, PJF
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) : 3 - 22
  • [5] Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
  • [6] 2-4
  • [7] Stir bar sorptive extraction-thermal desorption-capillary gas chromatography-mass spectrometry applied to the analysis of polychlorinated biphenyls in human sperm
    Benijts, T
    Vercammen, J
    Dams, R
    Tuan, HP
    Lambert, W
    Sandra, P
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 755 (1-2): : 137 - 142
  • [8] CARINS T, 1981, ANAL CHEM, V53, pA1183
  • [9] Comparison of soxhlet, shaking, and microwave assisted extraction techniques for determination of PCB congeners in a marine sediment
    Cicero, AM
    Pietrantonio, E
    Romanelli, G
    Di Muccio, A
    [J]. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2000, 65 (03) : 307 - 313
  • [10] Analytical applications of membrane extraction in chromatography and electrophoresis
    Cordero, BM
    Pavón, JLP
    Pinto, CG
    Laespada, MEF
    Martínez, RC
    Gonzalo, ER
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) : 195 - 204