Application of Receiver Operating Characteristic (ROC) Curves for Explosives Detection Using Different Sampling and Detection Techniques

被引:6
作者
Young, Mimy
Fan, Wen
Raeva, Anna
Almirall, Jose [1 ]
机构
[1] Florida Int Univ, Dept Chem & Biochem, Miami, FL 33199 USA
关键词
SPECTROSCOPY; CLASSIFICATION; SPECTROMETRY; POPULATION; MODELS; DRUGS; TOOL;
D O I
10.3390/s131216867
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reported for the first time are receiver operating characteristic (ROC) curves constructed to describe the performance of a sorbent-coated disk, planar solid phase microextraction (PSPME) unit for non-contact sampling of a variety of volatiles. The PSPME is coupled to ion mobility spectrometers (IMSs) for the detection of volatile chemical markers associated with the presence of smokeless powders, model systems of explosives containing diphenylamine (DPA), 2,4-dinitrotoluene (2,4-DNT) and nitroglycerin (NG) as the target analytes. The performance of the PSPME-IMS was compared with the widely accepted solid-phase microextraction (SPME), coupled to a GC-MS. A set of optimized sampling conditions for different volume containers (1-45 L) with various sample amounts of explosives, were studied in replicates (n = 30) to determine the true positive rates (TPR) and false positive detection rates (FPR) for the different scenarios. These studies were obtained in order to construct the ROC curves for two IMS instruments (a bench-top and field-portable system) and a bench top GC-MS system in low and high clutter environments. Both static and dynamic PSPME sampling were studied in which 10-500 mg quantities of smokeless powders were detected within 10 min of static sampling and 1 min of dynamic sampling. © 2013 by the authors; licensee MDPI, Basel, Switzerland.
引用
收藏
页码:16867 / 16881
页数:15
相关论文
共 32 条
[1]  
[Anonymous], 1999, Forensic and environmental detection of explosives
[2]   Evaluation of DOCK 6 as a pose generation and database enrichment tool [J].
Brozell, Scott R. ;
Mukherjee, Sudipto ;
Balius, Trent E. ;
Roe, Daniel R. ;
Case, David A. ;
Rizzo, Robert C. .
JOURNAL OF COMPUTER-AIDED MOLECULAR DESIGN, 2012, 26 (06) :749-773
[3]  
Carrano, 2005, CHEM BIOL SENSOR STA
[4]   Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry [J].
Cotte-Rodríguez, I ;
Justes, DR ;
Nanita, SC ;
Noll, RJ ;
Mulligan, CC ;
Sanders, NL ;
Cooks, RG .
ANALYST, 2006, 131 (04) :579-589
[5]   Multivariate analysis of standoff laser-induced breakdown spectroscopy spectra for classification of explosive-containing residues [J].
De Lucia, Frank C., Jr. ;
Gottfried, Jennifer L. ;
Munson, Chase A. ;
Miziolek, Andrzej W. .
APPLIED OPTICS, 2008, 47 (31) :G112-G121
[6]   Fast detection of triacetone triperoxide (TATP) from headspace using planar solid-phase microextraction (PSPME) coupled to an IMS detector [J].
Fan, Wen ;
Young, Mimy ;
Canino, Jon ;
Smith, James ;
Oxley, Jimmie ;
Almirall, Jose R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (02) :401-408
[7]   ROC-curve approach for determining the detection limit of a field chemical sensor [J].
Fraga, Carlos G. ;
Melville, Angela M. ;
Wright, Bob W. .
ANALYST, 2007, 132 (03) :230-236
[8]   Dynamic Planar Solid Phase Microextraction-Ion Mobility Spectrometry for Rapid Field Air Sampling and Analysis of Illicit Drugs and Explosives [J].
Guerra-Diaz, Patricia ;
Gura, Sigalit ;
Almirall, Jose R. .
ANALYTICAL CHEMISTRY, 2010, 82 (07) :2826-2835
[9]   Enhancement in sample collection for the detection of MDMA using a novel planar SPME (PSPME) device coupled to ion mobility spectrometry (IMS) [J].
Gura, Sigalit ;
Guerra-Diaz, Patricia ;
Lai, Hanh ;
Almirall, Jose R. .
DRUG TESTING AND ANALYSIS, 2009, 1 (7-8) :355-362
[10]  
Heramb R.M., 2002, FORENSIC SCI COMMUN, V4, P1