Non-invasive blood pressure and cardiac index measurements using the Finapres Portapres in an emergency department triage setting

被引:5
作者
Van der Does, Yuri [1 ]
Van Loon, Lex M. [2 ]
Alsma, Jelmer [3 ]
Govers, Annebel [3 ]
Lansdorp, Benno [2 ]
Rood, Pleunie P. M. [1 ]
Schuit, Stephanie C. E. [1 ,3 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Emergency Med, Rotterdam, Netherlands
[2] Univ Twente, Fac Sci & Technol, NL-7500 AE Enschede, Netherlands
[3] Erasmus Univ, Med Ctr, Dept Internal Med, Rotterdam, Netherlands
关键词
PULMONARY-ARTERY CATHETERIZATION; BALLOON-TIPPED CATHETER; COMPLICATIONS; HEART; CANNULATION; THERAPY; DISEASE; SYSTEM; OUTPUT; NEXFIN;
D O I
10.1016/j.ajem.2013.03.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Emergency department (ED) patients are triaged to determine the urgency of care. The Finapres Portapres (FP) measures blood pressure (BP) and cardiac output (CO) non-invasively, and may be of added value in early detection of patients at risk for hemodynamic compromise. Objectives: Compare non-invasive BP measurements using FP and standard automated sphygmomanometry. Compare FP cardiac index (CI), CO corrected for body surface area, of normotensive patients, to chart-based physician estimate of shock, to discover if there is additional value in CI measurements in triage. Methods: ED Patients requiring BP measurement in triage were included. Systolic (SBP) and diastolic (DBP) BP were measured using both devices during a two minutes measurement. Two physicians independently judged probability of shock, defined as estimated CI <= 2.5 L min(-1) m(-2), based on chart review, three weeks after ED visit. Results: Of a total of 112 patients 97 patients were included. Pearson's correlation coefficient was 0.50 for SBP, 0.53 for DBP, with a Blant-Altman mean bias of 11.3 (upper limit 65.3, lower limit -42.8) and 7.7 (39.2, -23.7) for SBP and DBP respectively. In normotensive patients, the group with low FP CI measurements had significantly more cases with physician-estimated shock, compared to the normal to high measurements (P = .036). Conclusions: When used as a triage device in the emergency department setting, non-invasive BP measurements using FP do not correlate well with automated sphygmomanometry. However, this study does indicate that use of the FP device in triage may aid physicians to recognize patients in early phases of shock. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1012 / 1016
页数:5
相关论文
共 28 条
[1]   Continuous Non-Invasive Blood Pressure Monitoring, a Validation Study of Nexfin in a Pregnant Population [J].
Akkermans, J. ;
Diepeveen, M. ;
Ganzevoort, W. ;
van Montfrans, G. A. ;
Westerhof, B. E. ;
Wolf, H. .
HYPERTENSION IN PREGNANCY, 2009, 28 (02) :230-242
[2]  
BARASH PG, 1981, J THORAC CARDIOV SUR, V82, P5
[3]   COMPLICATIONS OF PERCUTANEOUS RADIAL-ARTERY CANNULATION - OBJECTIVE PROSPECTIVE STUDY IN MAN [J].
BEDFORD, RF ;
WOLLMAN, H .
ANESTHESIOLOGY, 1973, 38 (03) :228-236
[4]   Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease [J].
Bogert, L. W. J. ;
Wesseling, K. H. ;
Schraa, O. ;
Van Lieshout, E. J. ;
de Mol, B. A. J. M. ;
van Goudoever, J. ;
Westerhof, B. E. ;
van Lieshout, J. J. .
ANAESTHESIA, 2010, 65 (11) :1119-1125
[5]   Results of a survey of blood pressure monitoring by intensivists in critically ill patients: A preliminary study [J].
Chatterjee, Arjun ;
DePriest, Kirk ;
Blair, Russell ;
Bowton, David ;
Chin, Robert .
CRITICAL CARE MEDICINE, 2010, 38 (12) :2335-2338
[6]   EFFECTS OF PERIPHERAL VASOCONSTRICTION ON THE BLOOD-PRESSURE IN THE FINGER, MEASURED CONTINUOUSLY BY A NEW NONINVASIVE METHOD (THE FINAPRES) [J].
DORLAS, JC ;
NIJBOER, JA ;
BUTIJN, WT ;
VANDERHOEVEN, GMA ;
SETTELS, JJ ;
WESSELING, KH .
ANESTHESIOLOGY, 1985, 62 (03) :342-345
[7]   Serial evaluation of the SOFA score to predict outcome in critically ill patients [J].
Ferreira, FL ;
Bota, DP ;
Bross, A ;
Mélot, C ;
Vincent, JL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (14) :1754-1758
[8]   PULMONARY COMPLICATIONS OF FLOW-DIRECTED BALLOON-TIPPED CATHETER [J].
FOOTE, GA ;
SCHABEL, SI ;
HODGES, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1974, 290 (17) :927-931
[9]   Methods in pharmacology: measurement of cardiac output [J].
Geerts, Bart F. ;
Aarts, Leon P. ;
Jansen, Jos R. .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2011, 71 (03) :316-330
[10]   Finapres tracking of systolic pressure and baroreflex sensitivity improved by waveform filtering [J].
Gizdulich, P ;
Imholz, BPM ;
vandenMeiracker, AH ;
Parati, G ;
Wesseling, KH .
JOURNAL OF HYPERTENSION, 1996, 14 (02) :243-250