A new cross contamination aware routing method with intelligent path exploration in Digital Microfluidic Biochips

被引:0
作者
Roy, Pranab [1 ]
Howladar, Pampa [1 ]
Bhattacharjee, Rupam [1 ]
Rahaman, Hafizur [1 ]
Dasgupta, Parthasarathi
机构
[1] Bengal Engn & Sci Univ, Sch VLSI Technol, Sibpur, India
来源
2013 8TH INTERNATIONAL CONFERENCE ON DESIGN & TECHNOLOGY OF INTEGRATED SYSTEMS IN NANOSCALE ERA (DTIS) | 2013年
关键词
digital microfluidics; Cross contamination; routing; detour; algorithm; resource utilization; ELECTROWETTING-BASED ACTUATION; LIQUID DROPLETS; CHIP;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Digital microfluidic systems in recent years have been developed as an alternative platform for execution of multiple conventional laboratory methods simultaneously on a single planar 2D array of electrodes targeted for biochemical analysis and biomedical applications. Due to its discrete nature droplets can be manipulated through multiple reconfigurable paths derived by preprogrammed electrode actuation sequences through this planar array known as digital microfluidic biochip system. Cross contamination between heterogeneous samples turns out to be a major issue concerned with transportation of droplets and correctness of the detection results for the bioassay protocols -which is highly significant for clinical diagnostics and toxicity monitoring applications. In this paper we have proposed an intelligent route path exploration technique that attempts partially or completely to avoid the number of cross contamination depending on the fluidic constraints employed during routing The path is further refined using intelligent detour by identifying zones of friction between two adjacent route paths that optimizes the overall route time by reducing the overall time for stalling while routing -as well as further optimization of resources to be utilized. The simulation is carried out on test benches of benchmark suite I and benchmark suite III. The results show improvement in overall as well as average route time and major reduction in the number of crossovers.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 50 条
[31]   A MULTI-PIN DROPLET ROUTING ALGORITHM FOR DIGITAL MICROFLUIDIC BIOCHIPS [J].
Roy, Pranab ;
Rahaman, Hafizur ;
Dasgupta, Parthasarathi .
BIODEVICES 2011, 2011, :216-+
[32]   A high-performance droplet routing algorithm for digital microfluidic biochips [J].
Cho, Minsik ;
Pan, David Z. .
IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2008, 27 (10) :1714-1724
[33]   An evolutionary algorithm with indirect representation for droplet routing in digital microfluidic biochips [J].
Jiang, Chen ;
Yang, Rong-Quan ;
Yuan, Bo .
ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2022, 115
[34]   Weighted optimization of various parameters for droplet routing in digital microfluidic biochips [J].
Pan, Indrajit ;
Samanta, Tuhina .
Advances in Intelligent Systems and Computing, 2014, 235 :131-139
[35]   Droplet Routing and Wash Droplet Scheduling Algorithm to Remove Cross-contamination in Digital Microfluidic Biochip [J].
Pan, Indrajit ;
Chatterjee, Soumyajit ;
Samanta, Tuhina .
2012 12TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS DESIGN AND APPLICATIONS (ISDA), 2012, :155-160
[36]   Voltage Driven Electrowetting based Microfluidic Operations for Efficient Droplet Routing in Digital Microfluidic Biochips [J].
Pan, Indrajit ;
Samanta, Tuhina .
2014 IEEE/ASME 10TH INTERNATIONAL CONFERENCE ON MECHATRONIC AND EMBEDDED SYSTEMS AND APPLICATIONS (MESA 2014), 2014,
[37]   Flexible Droplet Routing in Active Matrix-Based Digital Microfluidic Biochips [J].
Lu, Guan-Ruei ;
Kuo, Chun-Hao ;
Chiang, Kuen-Cheng ;
Banerjee, Ansuman ;
Bhattacharya, Bhargab B. ;
Ho, Tsung-Yi ;
Chen, Hung-Ming .
ACM TRANSACTIONS ON DESIGN AUTOMATION OF ELECTRONIC SYSTEMS, 2018, 23 (03)
[38]   Exact Routing for Micro-Electrode-Dot-Array Digital Microfluidic Biochips [J].
Keszocze, Oliver ;
Li, Zipeng ;
Grimmer, Andreas ;
Wille, Robert ;
Chakrabarty, Krishnendu ;
Drechsler, Rolf .
2017 22ND ASIA AND SOUTH PACIFIC DESIGN AUTOMATION CONFERENCE (ASP-DAC), 2017, :708-713
[39]   A new digital analyzer for optically detected samples in Digital Microfluidic Biochips [J].
Roy, Pranab ;
Chakraborty, Sudipta ;
Sohid, Moudud ;
Rahaman, Hafizur ;
Dasgupta, Parthasarathi .
2012 IEEE 55TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2012, :462-465
[40]   Waste-Aware Dilution and Mixing of Biochemical Samples with Digital Microfluidic Biochips [J].
Roy, Sudip ;
Bhattacharya, Bhargab B. ;
Chakrabarty, Krishnendu .
2011 DESIGN, AUTOMATION & TEST IN EUROPE (DATE), 2011, :1059-1064