A new cross contamination aware routing method with intelligent path exploration in Digital Microfluidic Biochips

被引:0
|
作者
Roy, Pranab [1 ]
Howladar, Pampa [1 ]
Bhattacharjee, Rupam [1 ]
Rahaman, Hafizur [1 ]
Dasgupta, Parthasarathi
机构
[1] Bengal Engn & Sci Univ, Sch VLSI Technol, Sibpur, India
来源
2013 8TH INTERNATIONAL CONFERENCE ON DESIGN & TECHNOLOGY OF INTEGRATED SYSTEMS IN NANOSCALE ERA (DTIS) | 2013年
关键词
digital microfluidics; Cross contamination; routing; detour; algorithm; resource utilization; ELECTROWETTING-BASED ACTUATION; LIQUID DROPLETS; CHIP;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Digital microfluidic systems in recent years have been developed as an alternative platform for execution of multiple conventional laboratory methods simultaneously on a single planar 2D array of electrodes targeted for biochemical analysis and biomedical applications. Due to its discrete nature droplets can be manipulated through multiple reconfigurable paths derived by preprogrammed electrode actuation sequences through this planar array known as digital microfluidic biochip system. Cross contamination between heterogeneous samples turns out to be a major issue concerned with transportation of droplets and correctness of the detection results for the bioassay protocols -which is highly significant for clinical diagnostics and toxicity monitoring applications. In this paper we have proposed an intelligent route path exploration technique that attempts partially or completely to avoid the number of cross contamination depending on the fluidic constraints employed during routing The path is further refined using intelligent detour by identifying zones of friction between two adjacent route paths that optimizes the overall route time by reducing the overall time for stalling while routing -as well as further optimization of resources to be utilized. The simulation is carried out on test benches of benchmark suite I and benchmark suite III. The results show improvement in overall as well as average route time and major reduction in the number of crossovers.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 50 条
  • [1] Cross-Contamination Avoidance for Droplet Routing in Digital Microfluidic Biochips
    Zhao, Yang
    Chakrabarty, Krishnendu
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2012, 31 (06) : 817 - 830
  • [2] A Contamination Aware Droplet Routing Algorithm for the Synthesis of Digital Microfluidic Biochips
    Huang, Tsung-Wei
    Lin, Chun-Hsien
    Ho, Tsung-Yi
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2010, 29 (11) : 1682 - 1695
  • [3] Unified Contamination-Aware Routing Method Considering Realistic Washing Capacity Constraint in Digital Microfluidic Biochips
    Huang, Zhipeng
    Bai, Xiqiong
    Lan, Tingshen
    Li, Xingquan
    Lin, Geng
    IEEE ACCESS, 2020, 8 : 192867 - 192879
  • [4] A new algorithm for routing-aware net placement in cross-referencing Digital Microfluidic Biochips
    Roy, Pranab
    Bhattacharjee, Rupam
    Rahaman, Hafizur
    Dasgupta, Parthasarathi
    2012 IEEE COMPUTER SOCIETY ANNUAL SYMPOSIUM ON VLSI (ISVLSI), 2012, : 320 - 325
  • [5] An Intelligent Compaction Technique for Pin Constrained Routing in Cross Referencing Digital Microfluidic Biochips
    Roy, Pranab
    Bhattacharjee, Rupam
    Sohid, Modud
    Chakraborty, Sudipta
    Rahaman, Hafizur
    Dasgupta, Parthasarathi
    CODES+ISSS'12:PROCEEDINGS OF THE TENTH ACM INTERNATIONAL CONFERENCE ON HARDWARE/SOFTWARE-CODESIGN AND SYSTEM SYNTHESIS, 2012, : 423 - 432
  • [6] Integrated Functional and Washing Routing Optimization for Cross-Contamination Removal in Digital Microfluidic Biochips
    Yao, Hailong
    Wang, Qin
    Shen, Yiren
    Ho, Tsung-Yi
    Cai, Yici
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2016, 35 (08) : 1283 - 1296
  • [7] A new heterogeneous droplet routing technique and its simulator to improve route performance in Digital Microfluidic Biochips
    Bhattacharya, Rupam
    Rahaman, Hafizur
    Roy, Pranab
    2016 INTERNATIONAL CONFERENCE ON MICROELECTRONICS, COMPUTING AND COMMUNICATIONS (MICROCOM), 2016,
  • [8] Synchronization of Washing Operations with Droplet Routing for Cross-Contamination Avoidance in Digital Microfluidic Biochips
    Zhao, Yang
    Chakrabarty, Krishnendu
    PROCEEDINGS OF THE 47TH DESIGN AUTOMATION CONFERENCE, 2010, : 635 - 640
  • [9] Cross-Contamination Aware Design Methodology for Pin-Constrained Digital Microfluidic Biochips
    Lin, Cliff Chiung-Yu
    Chang, Yao-Wen
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2011, 30 (06) : 817 - 828
  • [10] Practical Functional and Washing Droplet Routing for Cross-Contamination Avoidance in Digital Microfluidic Biochips
    Wang, Qin
    Shen, Yiren
    Yao, Hailong
    Ho, Tsung-Yi
    Cai, Yici
    2014 51ST ACM/EDAC/IEEE DESIGN AUTOMATION CONFERENCE (DAC), 2014,