Towards cone-beam CT thermometry

被引:0
作者
Li, Ming [1 ]
Abi-Jaoudeh, Nadine [2 ]
Kapoor, Ankur [2 ]
Kadoury, Samuel [3 ,4 ]
Xu, Sheng [2 ]
Noordhoek, Niels [5 ]
Radaelli, Alessandro [5 ]
Carelsen, Bart [5 ]
Wood, Bradford J. [2 ]
机构
[1] NHLBI, NIH, Bldg 10, Bethesda, MD 20892 USA
[2] NIH, Ctr Clin, Bethesda, MD USA
[3] Philips Res North America, Briarcliff Manor, NY USA
[4] Ecole Polytech Montreal, Montreal, PQ, Canada
[5] Philips Healthcare, Veenpluis, Netherlands
来源
MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING | 2013年 / 8671卷
关键词
CBCT thermometry; temperature monitoring; RFA ablation; Wronskian change detector; NON-INVASIVE THERMOMETRY; COMPUTED-TOMOGRAPHY; INTERVENTIONAL SUITE; FEASIBILITY; ABLATION; GUIDANCE; SCANNER;
D O I
10.1117/12.2006851
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Temperature monitoring and therefore the final treatment zone achieved during a cone-beam CT (CBCT) guided ablation can prevent overtreatment and undertreatment. A novel method is proposed to detect changes in consecutive CBCT images obtained from projection reconstructions during an ablation procedure. The possibility is explored of using this method to generate thermometry maps from CBCT images, which can be used as an input function for ablation treatment planning. This novel method uses a baseline and an intermittent CBCT scan, which are routinely acquired to confirm the needle position and monitor progress of the ablation. Accurate registration is required and assumed in vitro and ex vivo. A Wronskian change detector algorithm is applied on the compensated images to obtain a difference image between the intermittent and baseline scans. Finally, a thermal map created by applying a calibration determined experimentally is used to obtain the corresponding temperature at each pixel or voxel. We applied Wronskian change detector to detect the difference of two CBCT images, which have low signal to noise ratio, and calibrate Wronskian change model to temperature data using a gel phantom. We tested the temperature mapping with water and gel phantoms as well as pig shoulder. The experimental results show this method can detect temperature change within 5 degrees C for a voxel size of 1mm(3) (within clinical relevancy), and by consequence delineate the ablation zone. The preliminary experimental results show that CBCT thermometry is possible and promising, but may require pre-processing, such as registration for motion compensation between the baseline and intermittent scans. Further, quantitative evaluations have to be conducted for validation prior to clinical assessment and translation. CBCT is a widely available technology that could make thermometry clinically practical as an enabling component of iterative ablation treatment planning.
引用
收藏
页数:7
相关论文
共 20 条
[11]  
Jenne J.W., 1997, IEEE ULTR S P, P1377
[12]   Ultrasound-based elastography: A novel approach to assess radio frequency ablation of liver masses performed with expandable ablation probes - A feasibility study [J].
Kolokythas, Orpheus ;
Gauthier, Thomas ;
Fernandez, Anna T. ;
Xie, Hua ;
Timm, Brian A. ;
Cuevas, Carlos ;
Dighe, Manjiri K. ;
Mitsumori, Lee M. ;
Bruce, Matt F. ;
Herzka, Daniel A. ;
Goswami, Gaurav K. ;
Andrews, R. Torrance ;
Oas, Kelly M. ;
Dubinsky, Theodore J. ;
Warren, Bill H. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (06) :935-946
[13]   Three-dimensional CT with a modified C-arm image intensifier: Feasibility [J].
Linsenmaier, U ;
Rock, C ;
Euler, E ;
Wirth, S ;
Brandl, R ;
Kotsianos, D ;
Mutschler, W ;
Pfeifer, KJ .
RADIOLOGY, 2002, 224 (01) :286-292
[14]   C-Arm Cone Beam CT for Hepatic Tumor Ablation Under Real-Time 3D Imaging [J].
Morimoto, Manabu ;
Numata, Kazushi ;
Kondo, Masaaki ;
Nozaki, Akito ;
Hamaguchi, Shingo ;
Takebayashi, Shigeo ;
Tanaka, Katsuaki .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) :W452-W454
[15]   Dose recalculation in megavoltage cone-beam CT for treatment evaluation: Removal of cupping and truncation artefacts in scans of the thorax and abdomen [J].
Petit, Steven F. ;
van Elmpt, Wouter J. C. ;
Lambin, Philippe ;
Dekker, Andre L. A. J. .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (03) :359-366
[16]  
Quesson B, 2000, J MAGN RESON IMAGING, V12, P525, DOI 10.1002/1522-2586(200010)12:4<525::AID-JMRI3>3.0.CO
[17]  
2-V
[18]   Three-dimensional C-arm cone-beam CT: Applications in the interventional suite [J].
Wallace, Michael J. ;
Kuo, Michael D. ;
Glaiberman, Craig ;
Binkert, Christoph A. ;
Orth, Robert C. ;
Soulez, Gilles .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) :799-813
[19]   Technologies for guidance of radiofrequency ablation in the multimodality interventional suite of the future [J].
Wood, Bradford J. ;
Locklin, Julia K. ;
Viswanathan, Anand ;
Kruecker, Jochen ;
Haemmerich, Dieter ;
Cebral, Juan ;
Sofer, Ariela ;
Cheng, Ruida ;
McCreedy, Evan ;
Cleary, Kevin ;
McAuliffe, Matthew J. ;
Glossop, Neil ;
Yanof, Jeff .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (01) :9-24
[20]   NON-INVASIVE THERMOMETRY WITH A CLINICAL X-RAY CT SCANNER - COMMENT [J].
ZAMENHOF, RG ;
STERNICK, ES ;
CURRAN, BM .
MEDICAL PHYSICS, 1983, 10 (03) :374-374