Gating mechanism of mechanosensitive channel of large conductance: a coupled continuum mechanical-continuum solvation approach

被引:4
|
作者
Zhu, Liangliang [1 ,2 ]
Wu, Jiazhong [1 ]
Liu, Ling [3 ]
Liu, Yilun [1 ]
Yan, Yuan [1 ]
Cui, Qiang [4 ,5 ]
Chen, Xi [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Aerosp, State Key Lab Strength & Vibrat Mech Struct, Int Ctr Appl Mech, Xian 710049, Peoples R China
[2] Columbia Univ, Dept Earth & Environm Engn, Columbia Nanomech Res Ctr, New York, NY 10027 USA
[3] Utah State Univ, Dept Mech & Aerosp Engn, Logan, UT 84322 USA
[4] Univ Wisconsin, Dept Chem, Madison, WI 53706 USA
[5] Univ Wisconsin, Inst Theoret Chem, Madison, WI 53706 USA
基金
中国国家自然科学基金;
关键词
Mechanosensitive channel; Gating mechanism; Continuum mechanics; Continuum solvation model; Multi-scale simulations; MOLECULAR-DYNAMICS; ESCHERICHIA-COLI; MEMBRANE-PROTEIN; ION CHANNELS; MSCL CHANNEL; FORCE-FIELD; SIMULATION; SURFACE; MODEL; MECHANOTRANSDUCTION;
D O I
10.1007/s10237-016-0783-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Gating transition of the mechanosensitive channel of large conductance (MscL) represents a good example of important biological processes that are difficult to describe using atomistic simulations due to the large (submicron) length scale and long (millisecond) time scale. Here we develop a novel computational framework that tightly couples continuum mechanics with continuum solvation models to study the detailed gating behavior of E. coli-MscL. The components of protein molecules are modeled by continuum elements that properly describe their shape, material properties and physicochemical features (e.g., charge distribution). The lipid membrane is modeled as a three-layer material in which the lipid head group and tail regions are treated separately, taking into account the fact that fluidic lipid bilayers do not bear shear stress. Coupling between mechanical and chemical responses of the channel is realized by an iterative integration of continuum mechanics (CM) modeling and continuum solvation (CS) computation. Compared to previous continuum mechanics studies, the present model is capable of capturing the most essential features of the gating process in a much more realistic fashion: due mainly to the apolar solvation contribution, the membrane tension for full opening of MscL is reduced substantially to the experimental measured range. Moreover, the pore size stabilizes constantly during gating because of the intricate interactions of the multiple components of the system, implying the mechanism for sub-conducting states of MscL gating. A significant fraction (similar to 2/3) of the gating membrane strain is required to reach the first sub-conducting state of our model, which is featured with a relative conductance of 0.115 to the fully opened state. These trends agree well with experimental observations. We anticipate that the coupled CM/CS modeling framework is uniquely suited for the analysis of many biomolecules and their assemblies under external mechanical stimuli.
引用
收藏
页码:1557 / 1576
页数:20
相关论文
共 34 条
  • [1] Gating mechanism of mechanosensitive channel of large conductance: a coupled continuum mechanical-continuum solvation approach
    Liangliang Zhu
    Jiazhong Wu
    Ling Liu
    Yilun Liu
    Yuan Yan
    Qiang Cui
    Xi Chen
    Biomechanics and Modeling in Mechanobiology, 2016, 15 : 1557 - 1576
  • [2] Dynamics and Energetics of Gating Mechanism in Mechanosensitive Channel of Large Conductance (MscL)
    Tatikonda, Rajitha R.
    Vanegas, Juan M.
    BIOPHYSICAL JOURNAL, 2019, 116 (03) : 207A - 207A
  • [3] Gating and inactivation of mechanosensitive channels of small conductance: A continuum mechanics study
    Zhu, Liangliang
    Cui, Qiang
    Xiao, Hang
    Liao, Xiangbiao
    Chen, Xi
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 90 : 502 - 514
  • [4] Gating Mechanism of Mechanosensitive Ion Channels Studied by Continuum Mechanics
    Bavi, Navid
    Nomura, Takeshi
    Qin, Qinghua
    Martinac, Boris
    BIOPHYSICAL JOURNAL, 2014, 106 (02) : 554A - 555A
  • [5] Gating mechanisms of mechanosensitive channels of large conductance, I: A continuum mechanics-based hierarchical framework
    Chen, Xi
    Cui, Qiang
    Tang, Yuye
    Yoo, Jejoong
    Yethiraj, Arun
    BIOPHYSICAL JOURNAL, 2008, 95 (02) : 563 - 580
  • [6] The gating mechanism of the large mechanosensitive channel MscL
    Sergei Sukharev
    Monica Betanzos
    Chien-Sung Chiang
    H. Robert Guy
    Nature, 2001, 409 : 720 - 724
  • [7] The gating mechanism of the large mechanosensitive channel MscL
    Sukharev, S
    Betanzos, M
    Chiang, CS
    Guy, HR
    NATURE, 2001, 409 (6821) : 720 - 724
  • [8] Structural mechanism for gating of a eukaryotic mechanosensitive channel of small conductance
    Deng, Zengqin
    Maksaev, Grigory
    Schlegel, Angela M.
    Zhang, Jingying
    Rau, Michael
    Fitzpatrick, James A. J.
    Haswell, Elizabeth S.
    Yuan, Peng
    NATURE COMMUNICATIONS, 2020, 11 (01)
  • [9] Structural mechanism for gating of a eukaryotic mechanosensitive channel of small conductance
    Zengqin Deng
    Grigory Maksaev
    Angela M. Schlegel
    Jingying Zhang
    Michael Rau
    James A. J. Fitzpatrick
    Elizabeth S. Haswell
    Peng Yuan
    Nature Communications, 11
  • [10] Calculation of octanol/water partition coefficients using a quantum mechanical-continuum solvent model for solvation
    Gogonea, V
    Ciubotariu, D
    Baleanu-Gogonea, C
    Ciubotariu, C
    MATCH-COMMUNICATIONS IN MATHEMATICAL AND IN COMPUTER CHEMISTRY, 2000, (41) : 107 - 115