Performance evaluation of different configurations of solar humidification-dehumidification desalination system with subsurface condenser

被引:8
作者
Asgari, Behrad [1 ]
Bizhani, Mohammadreza [1 ]
Hakkaki-Fard, Ali [2 ]
Hannani, Siamak Kazemzadeh [1 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, RASES Lab, Azadi Ave, Tehran, Iran
[2] Univ Laval, Dept Mech Engn, Quebec City, PQ, Canada
关键词
Humidification; -dehumidification; Desalination; Solar film evaporator; Subsurface condenser; Condensation irrigation; HEAT-TRANSFER COEFFICIENTS; UNDERGROUND CONDENSATION; SOIL-TEMPERATURE; WATER PRODUCTION; EVAPORATION;
D O I
10.1016/j.enconman.2022.116186
中图分类号
O414.1 [热力学];
学科分类号
摘要
The solar humidification-dehumidification desalination system with a subsurface condenser is a promising renewable energy-based desalination system. This desalination system is particularly suitable for condensation irrigation in greenhouses, especially where conventional energy sources are limited. A computational model of the system comprising a horizontal solar film evaporator and a subsurface condenser is developed. A previously proposed hybrid analytical-numerical model for horizontal ground heat exchangers is modified for the subsurface condenser. An experimental setup of the subsurface condenser is also built and used to verify the developed model of the subsurface condenser. The developed model is then used to evaluate the long-term performance of several closed-loop configurations of the system and compare it with an open-loop system. It is demonstrated that the average daily water yield and Gained Output Ratio (GOR) of the closed-loop system are 115 % and 127 % higher than the open-loop system, respectively; however, the ground temperature increases significantly, which can lead to decreased respiration and root growth. According to the simulation results, using the air-cooled condenser, internal heat exchanger, and the hybrid system with both the air-cooled condenser and internal heat exchanger enhances the freshwater produced and GOR by 6.0 %, 6.3 %, and 10.8 %, respectively. The hybrid system outperforms other configurations and leads to only a 2.0 degrees C increase in the ground temperature over ten years of the system operation.
引用
收藏
页数:17
相关论文
共 40 条
[1]   Greenhouse cultivation feasibility using condensation irrigation (studied plant: Basil) [J].
Arabnejad, Hossein ;
Mirzaei, Farhad ;
Noory, Hamideh .
AGRICULTURAL WATER MANAGEMENT, 2021, 245
[2]   Effects of Soil Temperature on Growth and Root Function in Rice [J].
Arai-Sanoh, Yumiko ;
Ishimaru, Tsutomu ;
Ohsumi, Akihiro ;
Kondo, Motohiko .
PLANT PRODUCTION SCIENCE, 2010, 13 (03) :235-242
[3]   An experimental investigation on a portable bubble basin humidification/dehumidification desalination unit utilizing a closed-loop pulsating heat pipe [J].
Aref, Latif ;
Fallahzadeh, Rasoul ;
Avargani, Vahid Madadi .
ENERGY CONVERSION AND MANAGEMENT, 2021, 228
[4]   A hybrid analytical-numerical model for predicting the performance of the Horizontal Ground Heat Exchangers [J].
Bahmani, Mohammad Hossein ;
Hakkaki-Fard, Ali .
GEOTHERMICS, 2022, 101
[5]   Thin-layer solar drying characteristics of rough rice under natural convection [J].
Basunia, MA ;
Abe, T .
JOURNAL OF FOOD ENGINEERING, 2001, 47 (04) :295-301
[6]  
Bergman T. L., 2011, Fundamentals of heat and mass transfer
[7]  
Bolz R.E., 1976, HDB TABLES APPL ENG, Vsecond
[8]  
Cengel YA., 2001, Thermodynamics: An engineering approach, V4th ed.
[9]  
Dehghani S, 2018, EMERGING TECHNOLOGIES FOR SUSTAINABLE DESALINATION HANDBOOK, P227, DOI 10.1016/B978-0-12-815818-0.00007-2
[10]  
Dincer I., 2014, PROGR EXERGY ENERGY