A time and frequency measurement method based on delay-chain technique

被引:7
作者
Wang, Hai [1 ]
Zhou, Wei [1 ]
Li, Zhiqi [1 ]
Qian, Shixiang [2 ]
Jiang, Weining [2 ]
Wang, Chunxu [1 ]
机构
[1] Xidian Univ, Dept Measurement & Instrument, Xian 710071, Peoples R China
[2] Natl Key Elect Mesurment Technol, Qingdao 266555, Peoples R China
来源
2008 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, VOLS 1 AND 2 | 2008年
基金
美国国家科学基金会;
关键词
D O I
10.1109/FREQ.2008.4623046
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The short time-interval and frequency measurement are main research projects in the measurement of time and frequency. Traditional measurement methods include direct counting, analog interpolating, time-to-voltage conversion, time vernier and time-to-digital conversion. However these methods are all complicated and the instruments based on these methods are expensive. A novel method for short time-interval and frequency measurement based on delay-chain technique is presented in this paper. This method utilizes measured short time-interval or measured frequency signal to generate count gate. A delay-chain is used to delay reference frequency signal orderly. So a group of signals with phase-shifting evenly in a period of reference frequency signal are generated, and are counted respectively under the same count gate. With the average of the counts as the count of reference frequency, the decimal counting error is reduced and measurement accuracy is improved. The measurement resolution of this method for short time-interval and measurement accuracy for frequency are equal to the measurement results under condition of increasing frequency of reference frequency signal by the times of the number of delay unit in a delay-chain. An experiment demonstrates the resolution of short time-interval measurement and the accuracy of frequency measurement could be 100ps and respectively and the theoretical measurement resolution and accuracy could be higher. Although it needs more delay units and counters in order to achieve high-accuracy measurement, this is not a problem because new device has been used, such as FPGA. This method is suitable for high-accuracy and low-cost measurement..
引用
收藏
页码:484 / +
页数:2
相关论文
共 9 条
[1]  
*COMM HDB MEAS TEC, 1996, HDB MEAS TECHN, V11
[2]   A high-resolution CMOS time-to-digital converter utilizing a Vernier delay line [J].
Dudek, P ;
Szczepanski, S ;
Hatfield, JV .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2000, 35 (02) :240-247
[3]  
JOZEF K, 1997, IEEE T INSTRUMENTATI, V46, P51
[4]  
JOZEF K, 1997, IEEE T INSTRUMENTATI, V46, P851
[5]   A high-precision time-to-digital converter for pulsed time-of-flight laser radar applications [J].
Määttä, K ;
Kostamovaara, J .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (02) :521-536
[6]   Interpolating time counter with 100 ps resolution on a single FPGA device [J].
Szplet, R ;
Kalisz, J ;
Szymanowski, R .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (04) :879-883
[7]  
Zhou W, 1995, PROCEEDINGS OF THE 1995 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, P354, DOI 10.1109/FREQ.1995.483921
[8]   Some new methods for precision time interval measurement [J].
Zhou, W ;
Xuan, ZQ ;
Yu, JG .
PROCEEDINGS OF THE 1997 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1997, :418-421
[9]  
[周渭 Zhou Wei], 2003, [时间频率学报, Journal of Time and Frequency], V26, P87